  1. Replies
    6
    Views
    930

    It sounds like his unit uses the HSI for flame...

    It sounds like his unit uses the HSI for flame rectification also
  2. Replies
    6
    Views
    930

    when you say "Getting 24v across", do you mean...

    when you say "Getting 24v across", do you mean from pin to pin on each control that should be proving? Cuz of course you should get zero from pin to pin. Anyways, did you take out HSI and give it...
  3. Replies
    19
    Views
    1,609

    you got the SHORT BUS INSPECTOR!! However, if the...

    you got the SHORT BUS INSPECTOR!! However, if the mech room does not have 1 Sq inch per 1000btu at sealevel rating of fresh air, some inspectors call it because they wont consider pipe inlets as...
  4. Thread: trane question

    by ddog1
    Replies
    9
    Views
    779

    Train and AM Standards use reversing valve in A/C...

    Train and AM Standards use reversing valve in A/C . You should make sure Tstat is prog. for orange and r/v in cooling
  5. Replies
    0
    Views
    914

    tridelta pressure switch on carrier furnace

    anyone have the " WC specs for a TRIDELTA HK06WC076? i read it as a .76WC but need to be sure
  6. Replies
    2
    Views
    565

    kenmore chest freezer

    Anyone serviced a kenmore chest freezer with the following symptoms:
    Mod# 25316582102 2yrs old

    1) temp. rise alarm going off

    2) digital temperature located on center handle reading 78...
  7. Replies
    3
    Views
    642

    Lambfamily

    You need to insulate inside cabinet better than it is...it also sounds like you have a low return so if possible bring in a high return. And it is necessary to have fresh outside air in that...
  8. Replies
    5
    Views
    1,014

    Barriehie

    Pose these questions on the pro tech forums and if your not signed up, its easy and quick to do
  9. Replies
    5
    Views
    1,014

    Semper Fi

    Hey... your percentage is about right for oem motors. Keep in mind that poorly position fan blades in relation to the shroud can cause high amps ..."chopping".... Also improper run caps even if they...
  10. Wyman

    the no "Tech Help" rule on this site is for your physical protection and our legal protection. That being said, most honeywell systems are homeowner friendly and can be figured out without any...
  11. a little help

    "Clicking" zones usually indicate a striped actuator that in turn indicates too high static pressure due to poor by-pass air volume wich in turn strips actuators and burns out unit blower motors.......
  12. Replies
    16
    Views
    1,318

    My 2 cents

    Its so odd to see this thread today cuz I just finished installing a walk-in cooler and freezer system both new for a local meat processor. As I was kneeling in the wind, Brazing my 7/8" acr copper...
  13. Replies
    8
    Views
    6,033

    Humidifiers

    No excuses not to go with "NEW" honeywell steamers...check them out. Price is reasonable and you can install them up to 20' remote from Supply duct.
  14. Replies
    24
    Views
    1,919

    return

    That 14" return to the 3ton HP is waaaaaay short of required. Some installers will run 16" flex to a 3ton HP thinkin thier ductulator is also a flexulator...still not enough air usually
  15. Replies
    39
    Views
    3,523

    my 2 cents

    That schematic looks pretty basic and considering its all resistance(no heat pump)...your problem should be easily fixed. At first it sounds to me like the factory installed filter in the return of...
  16. Replies
    17
    Views
    1,696

    purpose...Tunnel

    As easy a way I know to explain how to Ground is to let you know the purpose of the ground. Gas lines are not grounded but "BONDED" to the house Neutral or bus bar depending on where the original or...
  17. Replies
    6
    Views
    811

    Tankless

    Where you at and gas or electric?
  18. Thread: kruger diffusers

    by ddog1
    Replies
    2
    Views
    578

    moose

    that be the one....thnx
  19. Thread: kruger diffusers

    by ddog1
    Replies
    2
    Views
    578

    kruger diffusers

    Anybody have the website for kruger diffusers please....thanks
  20. Replies
    14
    Views
    1,514

    troyorr

    I wuz tryin ta be phasicious. I will try harder next time
  21. Replies
    14
    Views
    1,514

    bobelectric

    One of those vendors you mentioned will sell you a motor you need to replace your existing con. fan motor if you DO have an account. The cert. you have qualifies you to change out the electro...
  22. Replies
    11
    Views
    1,104

    2 cents

    I might get jumped on for this by another tech, but you should know it is possible to de-rate a new 100,000 btu furnace to 70,000 btu by closing up an orfice or two if after install the new furnace...
  23. Thread: Board miss wire

    by ddog1
    Replies
    1
    Views
    600

    I serviced a 3yr old tempstar split system attic...

    I serviced a 3yr old tempstar split system attic furnace today and am kinda stumped. Found fan not working so I checked out the board and find the HI SPEED blower lead connected to the EAC pin on the...
  24. Replies
    7
    Views
    864

    Hey

    Kinda like askin for a reasonably priced pacemaker to save a little money on your tripple bypass ya know....wanna cut out the doc on markup!!
  25. Replies
    11
    Views
    808

    super

    the acid in mortor..concrete will eatup copper.
    for fix I suggest cutting a length of pipe in half and installing after carfully chippin out mortor around lineset
  26. Replies
    6
    Views
    3,668

    robbie

    Did you check amp on run windings...low or high??
  27. Replies
    11
    Views
    808

    super

    1 1/2" or 2" conduit have long sweeps as well as straight pipe... sometimes you cant go straight into the wall but come at a 45 or 90... also silicone is probably better than spray foam for water...
  28. Replies
    10
    Views
    698

    txborn

    Just a thought... all things being relative, do you think a 2x4x8 wall of air is easier to condition than a 2x4x8 wall considering that drywall can retain a calcuable amount of heat during the day if...
  29. Replies
    11
    Views
    808

    super

    I have always ran the lineset in 1 1/2" conduit thru the concrete then seal with foam in the conduit
  30. Replies
    24
    Views
    2,479

    tuscon

    You really dont need to know anything about SMACNA, manual j, manual D....dont get to miopic as a homeowner and try to micromanage a field of work that takes the average person 4 yrs to comprehend...
  31. Replies
    24
    Views
    2,479

    Tuscon

    The best way I can explain Swamp cooling vs. A/C is:

    Swamp/evap cooler systems are designed to "replace" air in the house with new saturated air by forcing it into the room. Now A/c units treat...
  32. Replies
    24
    Views
    2,479

    PSTU

    My comment on load calcs being worthless refers to how a conditioned space with an a/c conditions the air. This very articulate, thorough homeowner is replacing a swamp cooler with what I would...
  33. Replies
    24
    Views
    2,170

    Krunch

    Do you have a Government agency that monitors Contracrors...In my state we have a registrars of contractors that allows open investigations and complaints from homeowners to be easily checked on by...
  34. Cobalt

    These questions are better in the pros forum...anyways it sounds as if your service tech subconscious just blew up all over your keyboard. I choose only to comment on the "cheater cord" question; It...
  35. Joy

    If you do get a few contractors from the yellow pages, just remember that "most" of the time large outfits spend all thier money on the salesmans suit and tie and teeth whitening and not enough on...
  36. Replies
    24
    Views
    2,479

    tuscon

    You should be more concerned about register location and duct adjustment than weather 200sq over/under on refer. is a large concern.
    The price diff. between 3 to 3.5 is negligable considering your...
  37. charles2

    Always try to follow codes....no crap ha. But I would pose this question to you to possibly answer yours unless all your lookin for is tech data to cover your butt. If someone is burning dinner in...
  38. Replies
    14
    Views
    1,626

    Ditto

    Hotdog..Amickracing is right,there is tech data on drain flow. It should be treated as a "wet vent" wich is a plumbing term. positive and negative coils are determined by their relation to the...
  39. Thread: water leak

    by ddog1
    Replies
    5
    Views
    764

    Leak?

    As usuall, I find myself confused by the question.
  40. Replies
    42
    Views
    27,486

    EPICS

    If your still reading posts to your question...suggestions to attic fan temp. and input on necessity I feel I need say again set fan at 105 and be sure to phisycally inspect wiring; truss...
  41. Replies
    42
    Views
    27,486

    epics

    My experience...after running hvac service in Phoenix AZ for a couple years I will testify that attic fans do help regardless what someones boring ass website says. You tellin me that its better to...
  42. Thread: Guardian air

    by ddog1
    Replies
    5
    Views
    601

    Bobby

    Thanks for the info..thats what I was lookin for.
  43. Thread: Guardian air

    by ddog1
    Replies
    5
    Views
    601

    Bobby

    Im not sure of the nomenclature name or tech... I was just rappin with a buddy from another city and he mentioned it. He said it uses the uv light in supply good up to 3'x3' duct. He has only done a...
  44. Thread: Guardian air

    by ddog1
    Replies
    5
    Views
    601

    Any opinions about the Guardian air ultra violet...

    Any opinions about the Guardian air ultra violet air cleaner installed in supply...any practical experience
  45. Replies
    41
    Views
    3,795

    mommy

    Hey mommy...keep us posted on the outcome please. My money is still on a rodent with a bad nicotine habit, probably menthols.
  46. Replies
    6
    Views
    2,718

    Wayne

    From your discription it sounds as if the motor and duct can be fixed easally enough....just call back the contractor or get a new one out. The ducts can be braced off at the weak points and the...
  47. Replies
    26
    Views
    2,110

    attic fans

    Teri, you might ask the contractor about attic fans...they are easy to install and help augment attic temp. a lot better than some insulation as insulation wont keep the temp. down during static,...
  48. Replies
    14
    Views
    1,202

    Huh??

    Pardon the ebonics and Elmer Fudd speak HVAC HERO, for I was unaware of the unilatteral site rules that stated King James english is the only officially recognized communication medium recognized by...
  49. Replies
    14
    Views
    1,202

    asilva

    Pay no never mind to summa da commints ya mite hear on dis here site.. summa da members were mentawee and physicawee abused as apprentices....know what I mean
  50. Replies
    14
    Views
    1,669

    Hide it?

    Some people would be wanting to show that magnificent piece of electro-mechanics off..good unit. However it is your home and that big box does have the potential to ruin a romantic evening on a...