Search:

Type: Posts; User: toptwo

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    20
    Views
    2,102

    It's a 3 ton heat pump. The basement is 30x15, 8...

    It's a 3 ton heat pump. The basement is 30x15, 8 feet high.
  2. Replies
    32
    Views
    4,221

    See if the unit has split coils, some even are 3...

    See if the unit has split coils, some even are 3 rows deep. Can't recall any intellipacks having 3 rows but make sure.
  3. Replies
    20
    Views
    2,102

    Cool whip your from s.e. mich? Who doyou work fo...

    Cool whip your from s.e. mich? Who doyou work fo r?
  4. Replies
    20
    Views
    2,102

    What do you guys think?

    The salesman wants me to install a condenser in the basement of a commercial building. No air flow, no windows, no make up air???? I think he's nuts. Oh and it's a heat pump. I'm just venting...
  5. Replies
    3
    Views
    1,125

    It could be any of those problems you mentioned....

    It could be any of those problems you mentioned. It might be time to call in a pro before you end up being the power head for the valve... all winter long
  6. Replies
    12
    Views
    2,099

    Must have been lowest bidder.

    Must have been lowest bidder.
  7. Replies
    26
    Views
    1,629

    A fan cycler should be used when the compressor...

    A fan cycler should be used when the compressor will run in low ambient conditions to keep the saturation temperature in the condenser up.
  8. Thread: On call pay

    by toptwo
    Replies
    82
    Views
    19,020

    We get 1 hour a day for everyday were on call....

    We get 1 hour a day for everyday were on call. Thats at regular pay, then if we get called out we get 1.5 time for after hours and double time on Sunday. thats the unions rule.
  9. Replies
    4
    Views
    423

    I agree with milk-man you should call in a pro...

    I agree with milk-man you should call in a pro now, before you have to call one on the weekend.
  10. Thread: Steamer issue

    by toptwo
    Replies
    6
    Views
    490

    Steamer issue

    Which stat would you guys recommened for steam boiler. I would like one that i can set up the anticipator. The pressure switch seams like its working fine when the pipes are cold but when pipes are...
  11. Replies
    17
    Views
    1,074

    Same.

    Same.
  12. Replies
    17
    Views
    1,074

    Duplicate and No *.

    Duplicate and No *.
  13. Thread: membership

    by toptwo
    Replies
    1
    Views
    349

    membership

    Where do I go to become a pro member?
  14. Thread: heat pump help

    by toptwo
    Replies
    6
    Views
    459

    Ok I'm going pro

    Ok I'm going pro
  15. Thread: heat pump help

    by toptwo
    Replies
    6
    Views
    459

    I'm not a diy, never really looked into becoming...

    I'm not a diy, never really looked into becoming a pro member. Fyi I have been service tech for 10 years, and dont do much residential and have only worked on a heat pump 1 or 2 times.
  16. Replies
    39
    Views
    4,126

    Hartford, YES

    Hartford, YES
  17. Thread: heat pump help

    by toptwo
    Replies
    6
    Views
    459

    heat pump help

    Heat pump help, I'm trying to walk my buddy thru wiring a heat pump over the phone. It's a 2 stage Ruud furnace with a heat pump outdoors air/air.
    I'm not a heat pump gut but I told him that the...
  18. Replies
    17
    Views
    1,134

    It was under warranty, and it's a buddies house...

    It was under warranty, and it's a buddies house so for some good food and laughs it was worth it
  19. Replies
    17
    Views
    1,134

    It was under warrenty, and it's a buddies house...

    It was under warrenty, and it's a buddies house so for some good food and laughs it was worth it.
  20. Replies
    17
    Views
    1,134

    It is an Arcoaire model: NUG, 100,000 btu 90% ...

    It is an Arcoaire model: NUG, 100,000 btu 90%
    It took me almost 6 hrs with stopping every 10-15 minutes and talking with the homeowner. Now I remember why I dont care for residential work that...
  21. Replies
    17
    Views
    1,134

    Heat Exch.. change out time

    How long should it take to change out a primary and secondary heat exchanger in a residential unit?
  22. Replies
    30
    Views
    8,582

    You may as well get a bid to zone the basement...

    You may as well get a bid to zone the basement and main floor while your at it. Also dont let the size of equipment choose you/ each manufacture has different sizes you choose the one thats right for...
  23. Replies
    17
    Views
    1,696

    I dont think its a resriction with that back...

    I dont think its a resriction with that back pressure, check your coil for dirt????
  24. Replies
    12
    Views
    7,554

    How about an AUX switch.

    How about an AUX switch.
  25. Replies
    13
    Views
    951

    REALLY????

    REALLY????
Results 1 to 25 of 71
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event