    I am trying to fix a GE refrigerator model number...

    I am trying to fix a GE refrigerator model number GSS22IFPHCC. The compressor is not receiving any voltage when I plug it in only the inner lights come on. I changed the evaporator thermistor because...
  2. Replies
    15
    Views
    1,504

    VTP99: I've heard a similar phrase " When in...

    VTP99: I've heard a similar phrase " When in doubt, amp it out! " :grin2:
  3. Replies
    15
    Views
    1,504

    The troubleshooting of this refrigerator was...

    The troubleshooting of this refrigerator was unplanned last night and it was kind of late so I didn't have time to troubleshoot more systematically, but I will possibly revisit this case during the...
  4. Replies
    15
    Views
    1,504

    I did not condemn the compressor either not only...

    I did not condemn the compressor either not only for the same reason sandshark mentioned, but primarily because the compressor was not receiving any voltage at all I even left the volt-meter...
  5. Replies
    15
    Views
    1,504

    Questionable Compressor?

    I checked a refrigerator compressor which according to the customer had been diagnosed as bad compressor and I found the following readings:
    Run to Start: 2.2 ohm
    Run to Common: .4 ohm
    Start to...
  6. Replies
    6
    Views
    1,716

    Hello Phase Loss: I am thinking about installing...

    Hello Phase Loss: I am thinking about installing another R-134a compressor tomorrow morning, but this time I will not add any mineral oil. Is there anything I can do prior to installing the...
  7. Replies
    6
    Views
    1,716

    Compressor Oil for Household Refrigerator

    I would like to know what would be the implications for the following:
    I removed a compressor from a R-134a household refrigerator and replaced it with a used one, but before installing it I noticed...
  8. Replies
    16
    Views
    1,448

    Our teacher agreed on changing "lb per minute" to...

    Our teacher agreed on changing "lb per minute" to "gallons per minute" today in class. Evidently, the printed version of the problem received was inaccurate. Therefore the solution is as follows:
    ...
  9. Replies
    16
    Views
    1,448

    Problem from school with no resonse yet

    Helo Snewman,

    Another classmate and I got the same response: 9,000 Btu/hr, but our teacher said that it was incorrect, and I still don't know why. I will keep searching for a response. I...
  10. Replies
    16
    Views
    1,448

    Problem from school with no response yet

    Hello, this is the first time I try this web site. I go to school to become an HVAC technician, and we have a problem that we cannot solve, can anybody provide any ideas as to how to solve it? The...