    I'm trying to help you, but you keep failing to...

    I'm trying to help you, but you keep failing to read what I'm typing. And stating the same thing back to me that I'm telling you.

    This is the second post you did this. We are here to help you,...
  2. Replies
    13
    Views
    343

    You say when harvest did work your suction...

    You say when harvest did work your suction pressure was 80-90.
    In your earlier post you said harvest suction pressure was 45 psi
    cool vapor valve is hanging up intermittently on ya as well.
    ...
  3. Replies
    13
    Views
    343

    Cool vapor valve is what I called it in my post. ...

    Cool vapor valve is what I called it in my post.
    Cool vapor valve is piped into the top of the receiver and uses the gas that accumulated at the top of the receiver for harvest.
    As where a hot...
  4. Replies
    13
    Views
    343

    Suction pressure way too low for harvest. Will...

    Suction pressure way too low for harvest. Will not generate enough heat to shed the ice off the plate. Are you sure it's not a cool vapor valve that you are calling a hot gas valve. If so it will...
  5. Replies
    37
    Views
    1,279

    That's what I said in previous post. LoL:cheers:...

    That's what I said in previous post. LoL:cheers:

    Besides what residential out there even comes close to holding 50lbs :grin2:
  6. Replies
    37
    Views
    1,279

    Find a new company. The site of the leak should...

    Find a new company.
    The site of the leak should be located.
    How old is the system in question?
    A leak the large should be able to be found in 5 minutes with some nitrogen if the system is flat (...
  7. Replies
    37
    Views
    1,279

    You are 100% correct. Only systems exceeding...

    You are 100% correct.
    Only systems exceeding 50lbs
  8. Replies
    37
    Views
    1,279

    That EPA limit is only schedualed for commercial...

    That EPA limit is only schedualed for commercial systems exceeding 50lbs od refrigerant.

    Hope this helps

    To the OP
    The guy is just trying to make a sale if he is not giving you any options.
  9. Replies
    17
    Views
    773

    Bonnie , just checking to see if you found my...

    Bonnie , just checking to see if you found my email address.
  10. Replies
    17
    Views
    773

    If you'd like a second opinion you can find my...

    If you'd like a second opinion you can find my email in my profile, contact me and we can set up a time to see what you have going on with your system. I'm not too far away from you.
  11. Replies
    17
    Views
    773

    Your system is not oversized unless your home is...

    Your system is not oversized unless your home is super insulated...

    Thats just going off the information that was given to us.
  12. Replies
    17
    Views
    620

    http://www2.schneider-electric.com/resources/sites...

    http://www2.schneider-electric.com/resources/sites/SCHNEIDER_ELECTRIC/content/live/FAQS/130000/FA130583/en_US/Corner-Grounded%20Delta%202700DB0202.pdf


    Hope this helps
  13. Replies
    63
    Views
    4,153

    It's a shame they did that to ya... Hope this...

    It's a shame they did that to ya...

    Hope this is what you are looking for.


    http://www.mbm-service.de/mbmTechTwo/True_/GDM-5+/Service_Manual.pdf
  14. Your problem is not the size of the unit, it's in...

    Your problem is not the size of the unit, it's in your set up .

    The unit is sized properly , at a mid point average load you are looking at 50 btuh per square foot @ 7000 sq ft gives you 29.16...
  15. Replies
    31
    Views
    6,063

    Looking for qualifier in pinellas, hillsborough...

    Looking for qualifier in pinellas, hillsborough area to qualify company. Thanks
  16. Replies
    13
    Views
    796

    There are several variables Is the unit...

    There are several variables
    Is the unit residential or commercial
    Also from brand to brand ESP will vary.
    Need more information to be able to help you but I can tell you that the numbers you...
  17. That is the wrong compressor for what he's trying...

    That is the wrong compressor for what he's trying to accomplish...
    Not enough capacity.

    Hope this helps
  18. I suggest you call a new company or ask for a...

    I suggest you call a new company or ask for a senior tech to diagnose and if that was the senior tech , back to call out a new company.

    Sorry
  19. Thread: In need of

    by skpkey9
    Replies
    9
    Views
    448

    First Co. Also makes them. Hope this helps

    First Co. Also makes them.

    Hope this helps
  20. Replies
    33
    Views
    1,462

    JP- I have it someplace , will look for it in a...

    JP- I have it someplace , will look for it in a bit and get it over to you ..
  21. Replies
    21
    Views
    943

    Yes, But with 438 (MO99) there is a huge loss in...

    Yes, But with 438 (MO99) there is a huge loss in capacity... He need to let this one go.:.02:
    No good deed goes unpunished.:pop:

    Hope this helps...
  22. Replies
    21
    Views
    943

    Run Forest Run !!!:grin2:

    Run Forest Run !!!:grin2:
  23. Replies
    9
    Views
    571

    In cooling the evap check valve is closed, and...

    In cooling the evap check valve is closed, and yes there is a screen.
    It's possible ball is not seating properly causing frosting. For temporary repair, crimp check valve body with pinch off tool...
  24. Replies
    12
    Views
    838

    That bleed resistor is the same thing that you...

    That bleed resistor is the same thing that you find or install on a start cap, no difference

    Hope this helps:.02:
  25. Thread: No Superheat

    by skpkey9
    Replies
    57
    Views
    4,438

    You want the right direction. what is your ...

    You want the right direction. what is your subcool ?

    You came here with half the story and expect people guess the ending of the book when you only give them half the story at best..
    Don't mean...
  26. Replies
    9
    Views
    1,827

    It has an oversized bulb :grin2:

    It has an oversized bulb :grin2:
  27. Replies
    10
    Views
    617

    JP. Ya got me by under a minute ...lol

    JP. Ya got me by under a minute ...lol
  28. Replies
    10
    Views
    617

    2 things one is that they should not be concerned...

    2 things one is that they should not be concerned with air temp but rather product temp , and second if you are taking the box down to 34 or 35 degrees then product temp should not make it that...
  29. Replies
    26
    Views
    1,514

    Thank you:cheers:

    Thank you:cheers:
  30. Replies
    24
    Views
    780

    What is the original compressor model number ?...

    What is the original compressor model number ? The R-12 one...
  31. Replies
    26
    Views
    1,514

    X 3

    X 3
  32. Replies
    26
    Views
    1,514

    When using R-22 for low temp applications you...

    When using R-22 for low temp applications you need to have liquid injection to keep from frying the compressor... and that is why I commented on that post, you kept talking about R-22 as if was an...
  33. Replies
    26
    Views
    1,514

    Re- read your last post ...

    Re- read your last post ...
  34. Replies
    26
    Views
    1,514

    If you try to use R-22 In that compressor for a...

    If you try to use R-22 In that compressor for a low temp application you will destroy it.
  35. Replies
    26
    Views
    1,514

    See what valve is in the unit, possibly stamped...

    See what valve is in the unit, possibly stamped on valve body depending on age and valve. You can alway swap out valve and put 408 in it and be done with it.

    Hope this helps.
  36. Replies
    26
    Views
    1,514

    You are 100% correct MP-66 is the best for low...

    You are 100% correct MP-66 is the best for low temp 12...
  37. Replies
    23
    Views
    1,409

    Instead use a small Phillips screwdriver and go...

    Instead use a small Phillips screwdriver and go up about 9" from the end of the probe and wrap it tightly and make a pig tail. Looks better and works better. Use a larger Phillips to make slot for...
  38. Looking for Service Techs in the Tampa Bay area

    Looking for an experienced service tech with install experience, work duty entails light commercial, restaurant refrigeration, residential and last but not least some hot side work.

    wages based...
  39. Replies
    6
    Views
    488

    [QUOTE=UmmScott;18277841]Ok I wanna get your...

    [QUOTE=UmmScott;18277841]Ok I wanna get your guys' input on this...

    So 1st off I did NOT do the diagnosing on this ice maker. I was just sent to install the parts cuz the other tech was busy. I...
  40. Replies
    29
    Views
    1,892

    Are you sure the arrow is facing the right way......

    Are you sure the arrow is facing the right way...

    Also your differential should not be set for zero...

    Hope this helps...
  41. Replies
    21
    Views
    1,261

    Thanks...:cheers:

    Thanks...:cheers:
  42. Replies
    21
    Views
    1,261

    Well said !!!!! Hahaha

    Well said !!!!! Hahaha
  43. Thank you !!!! Been preaching tHis for years

    Thank you !!!!

    Been preaching tHis for years
  44. Tracer is causing the problem depending on your...

    Tracer is causing the problem depending on your set up, but my money is on the tracer unit as the culprit
    Might wat to try reprogramming could be a glitch first. I've had them do some crazy things...
  45. Replies
    3
    Views
    546

    Is this what you are looking for... ...

    Is this what you are looking for...

    http://content.amprobe.com/manualsA/A212X.pdf

    Hope this helps
  46. Replies
    28
    Views
    1,754

    2sac is more on track with this one....

    2sac is more on track with this one. Undercharged. You need to get that head up. Way to low.
    Hope this helps...
  47. Replies
    28
    Views
    1,754

    180 is usually 22 240 is usually 404

    180 is usually 22
    240 is usually 404
  48. Thread: wine cellar

    by skpkey9
    Replies
    43
    Views
    2,967

    OK I'm waiting on ya

    OK I'm waiting on ya
  49. Thread: wine cellar

    by skpkey9
    Replies
    43
    Views
    2,967

    Just seen what you posted, pressing on... ...

    Just seen what you posted, pressing on...

    I'm heading out for awhile , did you get the info you needed yet or do you still need help ???

    Did you get your SC. Dialed back. Yet.

    Sorry...
  50. Thread: wine cellar

    by skpkey9
    Replies
    43
    Views
    2,967

    I have lots , but if you are gonna be a smart ass...

    I have lots , but if you are gonna be a smart ass , then good luck. I've built and designed several wine rooms....

    Wish ya the best
Results 1 to 50 of 818
Page 1 of 17 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event