    I gotcha you thanks. I believe i can handle that....

    I gotcha you thanks. I believe i can handle that.
    And Orion i have not controlled one of these before, that is why i am looking for some insight. I have a customer who has some of these units and...
  2. Replies
    6
    Views
    202

    Thanks for the reply. Would you still use the...

    Thanks for the reply. Would you still use the zone dampers that made with unit for each duct opening?
  3. Replies
    6
    Views
    202

    York multi zone hot/cold deck

    Have a customer who has several multi zone hot and cold deck units. He is wanting to upgrade controls and actuators for the multi zone dampers. How do you upgrade something like this and control it...
  4. Replies
    6
    Views
    384

    Am watching it, the fans comes on for 10 min then...

    Am watching it, the fans comes on for 10 min then heat command and blows hot air
  5. Replies
    6
    Views
    384

    Carrier RTU open

    I have a few rtu opens on some carrier package units. I am having complaints about cold air blowing for 10 minutes before heat comes on. I went to the job today and saw that the fan was on for...
  6. Infinity greenspeed heatpump with two stage 97% furnace

    I just installed the greenspeed dual fuel heatpump. I am wanting to bring in outside are. Does anyone know if infinity accept IAQ. I have a 6" vav damper from ou piped into the return. I keep blower...
  7. Replies
    5
    Views
    441

    X2

    X2
  8. Replies
    1
    Views
    197

    Addition flex 6126

    I have an Addision package unit with a flex 6126 control. Which is Made by ALC. I GOT FIELD ASSISTANCE with there Lincese. I was able to find the controller when I upload it a window pops up and said...
  9. Replies
    2
    Views
    224

    Infinity wifi

    I am installing a infinity system with wifi. It comes with a router do I need to use this, since I already have wireless internet?
  10. Thread: Dust?

    by jeremyr325
    Replies
    13
    Views
    832

    Are you saying the supply is leaking in attic or...

    Are you saying the supply is leaking in attic or return is?
  11. Thread: Dust?

    by jeremyr325
    Replies
    13
    Views
    832

    Any one seen this

    Any one seen this
  12. Thread: Dust?

    by jeremyr325
    Replies
    13
    Views
    832

    Dust?

    Customer called today and said there ceiling vents have black stuff on them and the ceiling around them. we changed there furnace and coil about 2 years ago. It has a Carrier CSPHP4812 slab coil with...
  13. Replies
    3
    Views
    345

    Rock crushing facility

    I do some work for a rock crushing facility. I am needing some help on filtration.
    This is a large building with a crusher in the center of building with a control room, break room and electric room...
  14. Replies
    12
    Views
    2,011

    20o ton. Nice unit. If there is any offices...

    20o ton. Nice unit. If there is any offices joining the mech. room I would look into the sound blankets. It is not real loud just a high pitch. That is a screw for u though. Sound blankets help a...
  15. Replies
    5
    Views
    348

    appreciate yall's help.

    appreciate yall's help.
  16. Replies
    5
    Views
    348

    Trane VSEE vav

    i went to look at a job today, they are wanting to up grade there controls to I-vu. They have the trane VSEE vav boxes ( fan power and no fan boxes ), the problem i see is that they have the auger...
  17. Replies
    2
    Views
    367

    What are you trying to configure? 6400, plinks...

    What are you trying to configure? 6400, plinks 1600
  18. Replies
    10
    Views
    460

    Get on there network and go to port 8080 and do a...

    Get on there network and go to port 8080 and do a back up and then restore it.
  19. Replies
    6
    Views
    651

    Check out Founten.

    Check out Founten.
  20. Replies
    13
    Views
    998

    shut up stupid.

    shut up stupid.
  21. Replies
    13
    Views
    998

    What is ur problem dude. I was asking what does...

    What is ur problem dude. I was asking what does it take to start from scratch. We have a Bussiness, contracting, electrical , mechanical, plumbing Lincese. Insured, bonded so no i am not doing and...
  22. Replies
    13
    Views
    998

    It is not my first time. I have been in the...

    It is not my first time. I have been in the controls for several years and done well. I was looking at a different name because of giving my price to mechanical competitors that don't do controls for...
  23. Replies
    13
    Views
    998

    thanks crab master and tip261. We have been doing...

    thanks crab master and tip261. We have been doing controls under the same name for several years know. I was just seeing if that might help. thanks for the help
  24. Replies
    13
    Views
    998

    Hope you feel better. Lol

    Hope you feel better. Lol
  25. Replies
    13
    Views
    998

    License for controls

    I own a good size mechanical contractioning Bussiness in tn. We go building automaton under the same name. We are look at to changing the control side to a different name. I think we could get more...
  26. Replies
    12
    Views
    2,011

    I understand but it is A short piece of pipe....

    I understand but it is A short piece of pipe. Re-tubing is usually a two man job unless you have a cheap boss and if two people can't take that down then they need to retire. Also I bid against 3...
  27. Replies
    12
    Views
    2,011

    Latest chiller install

    511151511161511171
  28. Replies
    6
    Views
    312

    Just some good info try to share with people

    Just some good info try to share with people
  29. Replies
    6
    Views
    312

    Upgrade server to 6.0 service bulletin

    511091511101511111
  30. Replies
    11
    Views
    577

    FYI. The latest patches fixed this but if you...

    FYI. The latest patches fixed this but if you don't have it keep this in mind. Before you paste the path in the box you need to click on it to have you curser there then mover over one space with...
  31. Thread: Actuators

    by jeremyr325
    Replies
    3
    Views
    340

    Actuators

    Does any one know if you can get an electric actuators for a regular butterfly valve. I believe they are FNW valves. Got two chillers lead lag and want water cut of to one that s not running
  32. Replies
    12
    Views
    562

    Thanks

    Thanks
  33. Replies
    12
    Views
    562

    It is not that hard to understand it is laying in...

    It is not that hard to understand it is laying in the cieling grid the rest of the unit is above the cieling pretty simple the galvized book is sweating above cieiling. Condensation is puddling up on...
  34. Replies
    12
    Views
    562

    The expansion valve is inside the cassette. The...

    The expansion valve is inside the cassette. The lines are insulate. The cabinets are not designed to be in condition space. This is a 4 way ceiling cassette. The housing of the unit sticks above the...
  35. Yeah I could probably email it. He probably don't...

    Yeah I could probably email it. He probably don't have access to control side of partners. I don't use drop box a lot.
  36. I have drop box but not sure how to share it to...

    I have drop box but not sure how to share it to u. Do I need your Dropbox name or something. I never shared always have been on the receiving end
  37. good glad you got it fixed. There are many update...

    good glad you got it fixed. There are many update and patches. Does you HVAC contract monitor you facility off site? If so ask him to put the latest patches in. There is a August Cumulative patches...
  38. Replies
    22
    Views
    959

    Thank you!!! that is actually what is doing...

    Thank you!!! that is actually what is doing darctangent (BOSS)
  39. Replies
    57
    Views
    2,968

    You left running at 400 head. Wow. He hadn't...

    You left running at 400 head. Wow. He hadn't called back because he called somebody else cause it ain't cooling with them pressures.
    Btw nobody closed this thread it only been up for five days
  40. Replies
    22
    Views
    959

    I want to know how you check the compressor...

    I want to know how you check the compressor efficiency
  41. Replies
    57
    Views
    2,968

    You cannot blast the oxidation out. That is just...

    You cannot blast the oxidation out. That is just wasting some good nitrogen
  42. Replies
    57
    Views
    2,968

    What kind of unit and what size. Probably has...

    What kind of unit and what size. Probably has double row coil and still dirty. See it all the time. Get the model numb.
  43. Replies
    12
    Views
    562

    Lol sorry I use my ipad to look and post on this...

    Lol sorry I use my ipad to look and post on this forum every night. That is called auto correct and not proof reading.
    What I have is several samsung mini 4-ways. The building has a attic space...
  44. Replies
    4
    Views
    345

    Yes you can hard wire one OA sensor to one rtu...

    Yes you can hard wire one OA sensor to one rtu open and make the others look at. You will to go to properties/ network points found the OA sensor. Right click on it and global modify. It find all...
  45. Replies
    9
    Views
    2,006

    Like to see a few samples also. What is your turn...

    Like to see a few samples also. What is your turn round time on average
  46. Upgrade to 6.0 and put the august patch in

    Upgrade to 6.0 and put the august patch in
  47. Thread: Viso again

    by jeremyr325
    Replies
    14
    Views
    2,027

    i would like the stencils my self

    i would like the stencils my self
  48. Replies
    7
    Views
    409

    Need to get the static pressure. Need to get...

    Need to get the static pressure. Need to get supply and return static. You will probably be surprised
  49. Replies
    12
    Views
    562

    Sum sung mini 4-way cieling cassasttes

    I have install several of this in a school. Each room has there on ( not a Vrf ) they are sweating very badly on the tops. With is falling of and getting on cieling tile. There is is a lay in ceiling...
  50. Replies
    4
    Views
    345

    When u use the prism software for the wattsmaster...

    When u use the prism software for the wattsmaster controls it is user = admin and password = admin. You can try that hope it help