    You will find lots of help, mentors, equals and a...

    You will find lots of help, mentors, equals and a few just like you that get confused and frustrated and out of sorts at times. Hang in there.
  2. Replies
    34
    Views
    3,767

    Lots of water and the biggest straw hat I can...

    Lots of water and the biggest straw hat I can find. Some people laugh when they see me with my straw hat on, but those in the know smile and nod.
  3. Replies
    15
    Views
    2,508

    410A?

    410A?
  4. Thread: doin work

    by mikeybow
    Replies
    2
    Views
    494

    Good luck and God Bless! Keep on keeping your...

    Good luck and God Bless! Keep on keeping your buddies cool!
  5. Replies
    4
    Views
    886

    Get the info off the compresser if possible and...

    Get the info off the compresser if possible and the dimensions of the freezer box. They should be able to give you the coil size.
  6. Replies
    71
    Views
    5,522

    I will now.

    Normally I don't check the cap when everything is running correctly but I realize now that it would be prudent and a preemptive strike to do so. As always, CYOA!
  7. Replies
    4
    Views
    533

    Hahahahahahaha! Seriously, 20 TD across coil and...

    Hahahahahahaha! Seriously, 20 TD across coil and pulling untreated air from everywhere? Think about it!
  8. Replies
    16
    Views
    1,802

    Never had one come back! How long has that shop...

    Never had one come back! How long has that shop been open, one hour? They may say that but most places have had hundreds of motors, boards, caps, and all around parts come back. With all the parts...
  9. Replies
    28
    Views
    5,285

    In my area many of the HVAC companies want only...

    In my area many of the HVAC companies want only techs that are NATE certified. IN MY OPINION, I think NATE is like a big shiny button people wear to show off. At least 50% of the techs that are NATE...
  10. Replies
    12
    Views
    905

    A week to ten days?

    A week to ten days?
  11. Replies
    51
    Views
    11,906

    Based on your info, with an ODT of about 80, IDT...

    Based on your info, with an ODT of about 80, IDT of about 74, your unit sounds about right. Was there a problem with it? What was the T/D?
  12. Replies
    22
    Views
    2,458

    GE also.

    GE also.
  13. I'm there with you. Body hurts in places a body...

    I'm there with you. Body hurts in places a body should not have.
  14. Thread: R 22 dry unit

    by mikeybow
    Replies
    47
    Views
    6,213

    I seems to me we have heard from this individual...

    I seems to me we have heard from this individual before. GM?
  15. Replies
    16
    Views
    1,428

    Only the people that intend to work on the...

    Only the people that intend to work on the equipment install the equipment to make it easier to work on at a later date. This is true in all trades and facilities. I have spent countless hours in...
  16. Replies
    6
    Views
    1,366

    To answer your question, most hospitals use...

    To answer your question, most hospitals use residential, commercial, and specialty refridgeraters and freezers designed for what ever product their storing. About a year ago, I spent 6 months...
  17. Replies
    10
    Views
    1,055

    Need SOME info!

    Need SOME info!
  18. Thread: my luck

    by mikeybow
    Replies
    9
    Views
    757

    That and hooks, ladders, nails, electricity and...

    That and hooks, ladders, nails, electricity and millions of other sharp things are why I don't wear jewlery (especially rings) to work. I've seen too many burnt, cut and cut off fingers to take...
  19. Replies
    15
    Views
    1,943

    I started in hotels for 8 bucks an hour. I...

    I started in hotels for 8 bucks an hour. I learned a lot fast working on residental and commercial equipment. rough work for small pay but a good way to get experiance fast and almost always one out...
  20. Replies
    6
    Views
    1,052

    Have you ohmd it out? Checked voltages?

    Have you ohmd it out? Checked voltages?
  21. Replies
    16
    Views
    2,143

    Check the programming to make sure the...

    Check the programming to make sure the differantial set point between heat and cool is set correctly if t-stat has auto heat-cool capability. This time of year there is a fine line on temperture in...
  22. Replies
    20
    Views
    2,171

    The T-stat only directs the 24 vac. the system...

    The T-stat only directs the 24 vac. the system still has 24volts on it unless the T-stat is fried.
  23. Replies
    20
    Views
    2,171

    contacter, sequencer, relay(whatever gives the...

    contacter, sequencer, relay(whatever gives the fan it's power) corroded, welded, shorted in the closed position? Take the 24 vac off the system and see if the blower still runs. If it does then kill...
  24. Thread: cold weather

    by mikeybow
    Replies
    13
    Views
    908

    Unless I feel there is a problem with the temps...

    Unless I feel there is a problem with the temps after cleaning the coils and checking the voltages and the amps of all the motors I do not hook my gages to the system. You can never get 100% of the...
  25. Thread: michaelg55

    by mikeybow
    Replies
    30
    Views
    2,836

    Not sure about the new rules but when I recieved...

    Not sure about the new rules but when I recieved my universal a type 1 could only work on small appliances with less than 5 lbs. of refer. Most new 410-A H/Ps hold more than 5 lbs. Under those...
  26. Replies
    32
    Views
    2,383

    Every one is paying attention! That's how we...

    Every one is paying attention! That's how we disect a problem and determine wether or not it's a DIYer or a tech with a real dilema.
  27. Thread: Frozen coil

    by mikeybow
    Replies
    4
    Views
    577

    What brand is unit? what kind of compressor?...

    What brand is unit?
    what kind of compressor?
    What was indoor temp?
    Bad txv, restriction, bad suction valve, I/D airflow restriction?
  28. Replies
    7
    Views
    748

    I had a call about a bad smell one time. As soon...

    I had a call about a bad smell one time. As soon as i walked in the door you knew something was dead. Pulled the frige out and a rat had tried to climb behind the condenser coil and got stuck. That...
  29. Replies
    18
    Views
    1,892

    I should have said useing a filter dryer can't...

    I should have said useing a filter dryer can't hurt and can only help. a dryer will not reclaim the refrigerant to new status. It is up to the tech and h/o (old versus new cost wise) to determine to...
  30. Replies
    7
    Views
    748

    Many GEs and other brands have condensate catch...

    Many GEs and other brands have condensate catch pans underneath the refrigerater that can smell pretty bad if they haven't been cleaned in awhile. Most can be acessed from the front of the frige at...
  31. Replies
    18
    Views
    1,892

    As long as there was not a burnout it should be...

    As long as there was not a burnout it should be safe to put it back into the machine it came out of. If you suspect theres something wrong with it use an acid test kit. If you think there might be...
  32. Replies
    11
    Views
    973

    I'm in the process of installing a carrier...

    I'm in the process of installing a carrier infinity green speed system in my house. All motors (blower, odf and compressor) are variable speed. The ui communicates constantly with i/d, o/d units to...
  33. Please don't kill the pink slime! The meat...

    Please don't kill the pink slime! The meat markets would go out of busness.
  34. Replies
    24
    Views
    2,875

    G is not normally common. It is in most...

    G is not normally common. It is in most applications what the t-stat uses to communicate with the fan control. common is connected to the common side of the x-former. If it comes into contact with...
  35. Thread: TXV ISSUE

    by mikeybow
    Replies
    19
    Views
    1,231

    first, make sure the txv bulb is in the right...

    first, make sure the txv bulb is in the right position and firmly attached . If it still hunts try removing the bulb and add heat and cold. if it still hunts after checking charge, super heat and...
  36. Replies
    148
    Views
    10,766

    Have the customer pay for the equipment up front....

    Have the customer pay for the equipment up front. That's what I do and if they won't pay the balance all your out is the labor. Easier to get that back or at least won't hurt as much.
  37. Replies
    16
    Views
    1,685

    if conditions warrent flux, use silver solder....

    if conditions warrent flux, use silver solder. more expensive but stronger joint and less prone to o/d conditions.
  38. Is the gas primary or aux. heat? If primary, need...

    Is the gas primary or aux. heat? If primary, need to ck. all aspects of furnace. If they have hp, maybe problem with hp makeing gas run more. had that happen with a ho. hp quit and they didnt notice...
  39. Replies
    34
    Views
    3,080

    I agree. With the temps and psi you describe,...

    I agree. With the temps and psi you describe, maybe low charge. did you weigh in charge?how long did it run? on a new startup give it time for the system to equilize then take your readings. if...
  40. Replies
    9
    Views
    964

    ck. incoming voltage. should have 120-124vac....

    ck. incoming voltage. should have 120-124vac. min. 118.
  41. Replies
    16
    Views
    3,800

    If the refrigerant in the system gets too hot,...

    If the refrigerant in the system gets too hot, the compounds will begin to break down forming acids that will mix with the oil. If the system does not get hot enough to cause a burnout the acid stays...
  42. Replies
    31
    Views
    2,483

    Keep it in perspective. As you gain experiance,...

    Keep it in perspective. As you gain experiance, knowledge, and money you you will discover many new gadgets, tools and time savers to assit you in your trade. Just starting out, I believe a new 4...
  43. Replies
    31
    Views
    2,483

    Indeed. Not to mention time saved between evac....

    Indeed. Not to mention time saved between evac. and charge.
  44. Thread: Air Condition

    by mikeybow
    Replies
    18
    Views
    1,254

    If that were true, there would be no one left to...

    If that were true, there would be no one left to post. the being weird part. might be just me though?
  45. Replies
    11
    Views
    666

    Replace cap. If fan has been trying to run with...

    Replace cap. If fan has been trying to run with only run windings and has kicked off on overload several times it will remain hot for a long time. If fan has had time to cool, energize unit and try...
  46. Replies
    14
    Views
    1,624

    Hey, that's what bosses are for. Those who can't...

    Hey, that's what bosses are for. Those who can't boss those who can!
  47. Replies
    1
    Views
    442

    Wireing diagram for comfortmaker

    I got a call on a comfortmaker heat pump. 3.5 ton, mod. #YF042G, ser. #R915100225. HO said he had an oil furnace installed and the heat pump would not work. Got there and wires hanging everywhere. no...
  48. Replies
    9
    Views
    730

    If the bearings were seizing up, they might have...

    If the bearings were seizing up, they might have forgotten to switch the drain plugs. (pluged on top, removed on bottem).Does sound like wrong rpms for that unit.
  49. Replies
    15
    Views
    1,507

    H.D. bucket head

    I bought a home depot bucket head wet/dry vac. 6 months ago to carry in vechicle for $20 bucks. Fits on any 5 gal. bucket. Compact, med. power, easy to move around and tough. Very good for the price.
  50. Replies
    43
    Views
    3,719

    You should also consider the time frame involved...

    You should also consider the time frame involved with refrig. v residential. With resid., you might be able to wait a day. With refrig., it has to be done NOW due to the product liability. If you...