  1. Replies
    0
    Views
    76

    OS2 ULTIVIST UPGRADING

    We have one old site with ULTIVIST on OS/2,Owner want to upgrade their system.There are DMS 350 Controllers. So which software and controllers are most suitable to upgrade this system.Thanks.
  2. Replies
    8
    Views
    308

    Hi Dan

    I will check about backup file,I am not at same site at this time Ithink front end is EBI,let me check it tomorrow
    if you can give me hint about backup file name.Thanks.
  3. Replies
    8
    Views
    308

    Very nice information, We are AC service...

    Very nice information, We are AC service co.Honeywell don't sell us Care software is there any other source from where to buy Care software.Thanks.
  4. Replies
    8
    Views
    308

    SKWSPROUL

    I am thankful to your reply
  5. Replies
    8
    Views
    308

    Honeywell XCL5010 Question

    We have one faulty XCL5010 Controller,When we will replace it with new one is there any programming required or it will upload itself.Thanks.
  6. Replies
    1
    Views
    317

    Tac i/net Seven CD Key

    We have HVAC System with Tac i/net Seven 2.21 installed,There is virus in PC and we want to Format it.We have original CD but Key is not written on it,the person who install it long back left company...
  7. Replies
    0
    Views
    200

    Telemecanicque LT6 Motor Controller

    I have one new site with Telemecanicque LT6 Motor
    control Modules,One Module is not working and other
    has very small Star to Delta transition time,to check
    the problems LA9PA620 Software...
  8. Replies
    0
    Views
    168

    Mcquay Microtech ll Code

    Anybody have idea what is meaning of Microtech code like
    PCO2 MQ3BL0
    PCO2 000BM0
    PCO2 000BL0
    PCO3 MQ0BM0
    Or any refrence litraure to understand these codes.Thanks.
  9. Replies
    4
    Views
    526

    Thanks for reply.I think revision is for...

    Thanks for reply.I think revision is for controller and serial card for communication can be same to work with both controllers.
  10. Replies
    4
    Views
    526

    McQuay MicroTech II

    What is difference between PCO3MQ0BS0 and
    PCO3MQ0BM0.We have one faulty Lon Serial Card in PCO3MQ0BS0.Can we replace it from
    spare controller PCO3MQ0BM0.Are both cards
    compatible.Thanks.
  11. Replies
    5
    Views
    834

    will you tell me what Data points you...

    will you tell me what Data points you required.Thanks.
  12. Replies
    5
    Views
    834

    York YK Centrifugal Chiller

    We have 3 YK series york chillers R134a cooling capacity 1500 Tons.One of the chiller is surging too much condenser Sub cooling is around 10 Deg F.Its motor is 3.3Kv,Ampares are are fluctuating...
  13. Replies
    2
    Views
    400

    AHU reverse connections

    Normally Ahu Water supply is from down and return from up,but at one site contractor connect Supply from Up so what can be effect on performance of Ahu.This Ahu is 948 MBH capacity.Thanks.
  14. Replies
    1
    Views
    337

    Invensys MN 620

    Where can I get Invensys MN 620 Application Template.Thanks.
  15. Replies
    9
    Views
    654

    Model LD 100 Dual Source Made in Ireland

    Model LD 100 Dual Source
    Made in Ireland
  16. Replies
    9
    Views
    654

    how to reach Sub menu?

    how to reach Sub menu?
  17. Replies
    9
    Views
    654

    Humidity is 52 and Humidity set point was 26, I...

    Humidity is 52 and Humidity set point was 26, I change it to 52 but compressor contactors are remain energized.Room Temp is 17 and setpoint is 19 C.Is there some software programming problem.
  18. Replies
    9
    Views
    654

    It is Air cool system but dual coils Evaporator...

    It is Air cool system but dual coils Evaporator coils for compressors and other coils for chilled water.There are two set of heaters with two separate contactors
    Thanks for reply.
  19. Replies
    9
    Views
    654

    Thanks for your reply let me check and I will...

    Thanks for your reply let me check and I will write.
  20. Replies
    9
    Views
    654

    LIEBERT EXPERTS

    We have Liebert Unit System4 Level5.It is down flow type.Temperature setpoint is 19 C , It is working on chilled water,In display screen Temperature is showing 17 C.Both compressor contactors are...
  21. Replies
    5
    Views
    439

    It is 1095 not 109s.Thanks.

    It is 1095 not 109s.Thanks.
  22. Replies
    5
    Views
    439

    York Screw Chiller

    Hi,Anybody knows where to buy Motherboard 031-0109SE000 for York Screw Chiller.Thanks.
  23. Thread: EUROTHERM VFD

    by coldrig
    Replies
    0
    Views
    191

    EUROTHERM VFD

    EUROTHERM VSD Model No : 650VD Password is lost anybody have idea of backdoor Password.Thanks.
  24. Thread: McQuay Expert

    by coldrig
    Replies
    4
    Views
    387

    Hi,How to know if it is Bacnet or Modbus.I think...

    Hi,How to know if it is Bacnet or Modbus.I think it is Lon,Because it is connected with Honeywell BAS System and Honeywell is Lon.You think any version of Communication card can work or there are...
  25. Replies
    1
    Views
    711

    McQuay AGS Chiller MicroTech ll

    We have two McQuay AGS chillers one of the chiller not communicating with BAS so when we swap Lonworks Communication Module from MicroTech ll,it
    start communicating and we receive data from...