Search:

Type: Posts; User: sammy37

Page 1 of 16 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    35
    Views
    3,028

    Looks great. I think I would have mounted the EIM...

    Looks great. I think I would have mounted the EIM somewhere else, at least where it could be better serviced. No worries on the gas flex, thats all we use here.
  2. Replies
    29
    Views
    2,792

    I've got three old 80's Ford diesel trucks, two...

    I've got three old 80's Ford diesel trucks, two with aftermarket turbos and have found that in keeping the fuel cranked down and the timing set right, will give more power as opposed to rolling coal...
  3. Replies
    21
    Views
    2,343

    I know it's not common for most of you guys but...

    I know it's not common for most of you guys but this is why I prefer rooftop units. Rtu's dont get near the dirt or damage that I see on some of these poor cu's.
  4. Replies
    57
    Views
    8,804

    Not a Goodman. By the colors, I was thinking...

    Not a Goodman. By the colors, I was thinking Trane.
  5. Replies
    8
    Views
    2,391

    Thats the era when Goodman had so many HX...

    Thats the era when Goodman had so many HX failures.
  6. Replies
    27
    Views
    6,009

    Dumbest one in the valley also!

    Dumbest one in the valley also!
  7. Thread: NO!

    by sammy37
    Replies
    64
    Views
    11,145

    I'm affraid I dont agree with changing a unit...

    I'm affraid I dont agree with changing a unit around from the factory design. I've seen people here cut holes into package units to compensate for wrong duct locations but I bet when it comes to...
  8. Replies
    10
    Views
    2,253

    Yeah mine is on the roof. Do you remember the...

    Yeah mine is on the roof.

    Do you remember the story a few years back? Goodman had a large run of units that had no UV protection in the paint, they faded to a real ugly chalky light gray in less...
  9. Replies
    10
    Views
    2,253

    Thats the same unit I put on our house, little 3...

    Thats the same unit I put on our house, little 3 ton unit cools our 1835 sq ft quite well. Has a very noisy recip though, had to put a compressor blanket on it.
    The paint still sucks on this...
  10. Replies
    9
    Views
    1,675

    I hope I didnt sound harsh, just learned over the...

    I hope I didnt sound harsh, just learned over the years that hacks do stupid things and quite a few jobs have hidden surprises.
  11. :eek2: I'm speechless!

    :eek2: I'm speechless!
  12. Replies
    9
    Views
    1,675

    Rooftop resi has been the norm out west for many...

    Rooftop resi has been the norm out west for many many years. I really like having one complete package up on the roof and out of the way.
    However, they dont offer too many options for two stage heat...
  13. Replies
    9
    Views
    1,675

    Someone should have noticed the duct arrangement...

    Someone should have noticed the duct arrangement in the attic when the job was bid, then you would know that it was an over/under setup to begin with.
    Dont know why the last installer didnt just...
  14. Replies
    7
    Views
    1,606

    Wow, surprised to see a swamp cooler in Florida....

    Wow, surprised to see a swamp cooler in Florida. I'm sure it must be for just make up air but you definately wouldnt want to hook water up to it in that enviornment.
  15. Replies
    27
    Views
    4,003

    When people do crappy work like this, it's either...

    When people do crappy work like this, it's either because they dont like their job, or they have zero common sense. Usually the latter.
  16. Replies
    40
    Views
    8,337

    Its mounted in the supply. Thats the craziest...

    Its mounted in the supply. Thats the craziest thing I've ever seen and completely useless.
  17. Thats an over/under roof top unit. Kinda scary...

    Thats an over/under roof top unit. Kinda scary when they mount em like that.
  18. Replies
    6
    Views
    1,576

    The old Amana in pic #3, those were great units,...

    The old Amana in pic #3, those were great units, however the slanted evap coil occasionaly would drip down the return duct on downshot setups. All in all, they ran like tanks.
  19. Thread: Package unit

    by sammy37
    Replies
    13
    Views
    2,310

    Thats an awful small supply for that size of...

    Thats an awful small supply for that size of unit, wonder what the return looks like?
  20. Replies
    13
    Views
    3,227

    It was a nice turnout. I took a few moments to...

    It was a nice turnout. I took a few moments to introduce myself to his daughters and listen to them walk down memory lane.

    Marvin talked highly of you Doug and your Digi-cool program. Once in a...
  21. Replies
    13
    Views
    3,227

    His daughter just called me and told me the news....

    His daughter just called me and told me the news. For anyone that lives in the Vegas area, there will be a gathering for him at the Sahara saloon this coming monday evening at 7:00 PM.

    I too will...
  22. Replies
    34
    Views
    5,937

    That GPH Goodman is a non convertible unit,...

    That GPH Goodman is a non convertible unit, horizontal discharge only.
    A double changeover box would have worked fine, used many here and they only require an extra couple feet of space.
  23. Replies
    18
    Views
    3,075

    I would say that is one rock solid unit!:grin2:

    I would say that is one rock solid unit!:grin2:
  24. Replies
    27
    Views
    7,488

    I always hated these units, Goodman coppied the...

    I always hated these units, Goodman coppied the same design on theirs. We still have hundredes of these old Rheem and Goodmans around here.
  25. Replies
    11
    Views
    610

    I thought we couldnt post technical info? I just...

    I thought we couldnt post technical info? I just made simple suggestions to help the homeowner get the best install.
  26. Replies
    16
    Views
    1,307

    Yes, those look nice. I especially like the first...

    Yes, those look nice. I especially like the first one with the non adjustable curb.
    Also, some residential units provide a little less airflow when mounted downshot. The Goodman GPG is the worst for...
  27. Replies
    16
    Views
    1,307

    I dont know what the norm is in Mesa Jason but in...

    I dont know what the norm is in Mesa Jason but in Vegas, the only people using these adjustable curbs are mostly hacks and that is so they can get in and get out quick. Like I said in my last post,...
  28. Replies
    16
    Views
    1,307

    First off, an adjustable store bought roof curb...

    First off, an adjustable store bought roof curb requires no skill from the contractor. A good contractor will measure the pitch of your roof, measure your existing ductwork on the roof and have a...
  29. Replies
    16
    Views
    1,307

    In all of the pics, those roof curbs are sitting...

    In all of the pics, those roof curbs are sitting on top of the shingles. Those adjustable curbs need to be slid under the shingles.

    I'm not a fan of pulling flex duct through the roof and...
  30. Replies
    16
    Views
    1,307

    I've seen his stuff and I think he advertises on...

    I've seen his stuff and I think he advertises on craigslist. Thats what I would consider kind of Hack.
  31. Replies
    16
    Views
    1,307

    I have no problem with a curb adapter on a...

    I have no problem with a curb adapter on a commercial building when it's done right.
    As far as residential, most hacks around here are using adjustable pre made roof curbs and not even properly...
  32. Replies
    16
    Views
    1,307

    Some will argue that mounting the unit downshot...

    Some will argue that mounting the unit downshot is better, maybe I would prefer to do it with a stand and not a roof curb. In the future when someone has to replace that unit, it will be easier to...
  33. I understand doing it right, I wont do a job...

    I understand doing it right, I wont do a job unless it's right. Eventually these units around here that have been put on adjustable curbs are going to need to be replaced, especially since most of...
  34. Funny you mention the railings, because I was...

    Funny you mention the railings, because I was born and raised in the Fresno area and most residential rooftop units over a certain pitch, had a catwalk mounted around them. You definately dont see...
  35. On another note to precison havc, your install...

    On another note to precison havc, your install looks great and it appears that you do nice work. Always nice to see the stat wire protected, I get really annoyed when I see stat wire exposed all over...
  36. I'm afraid after growing up with old timers and...

    I'm afraid after growing up with old timers and doing many rooftop changeouts, I hate residential roof curbs! What happens now when someone comes along and has to replace that unit with a unit that...
  37. Replies
    10
    Views
    653

    The OP is making a little confusion with his...

    The OP is making a little confusion with his terminology. I thought he needed a new compressor also by his wording. I think he is refering to replacing his condensing unit, along with replacing the...
  38. I'm curious as to what size the return duct is?...

    I'm curious as to what size the return duct is? What size is the return grill?
  39. Replies
    4
    Views
    437

    And now that I think about it, Rheem/Ruud may be...

    And now that I think about it, Rheem/Ruud may be the only one that makes a 1.5 ton packaged unit. Someone correct me if I'm wrong.
  40. Replies
    4
    Views
    437

    Dont go bigger. If you want, you can download the...

    Dont go bigger. If you want, you can download the software from this site and run your own load calc to see what your home truly needs. Did the 1.5 ton do its job properly? What shape is your...
  41. Replies
    4
    Views
    437

    Dont raise the unit and vent it downshot, looks...

    Dont raise the unit and vent it downshot, looks like hell sometimes.
    Find a competent shop to build an over/under to side by side transition, it usually doesnt set the unit too far back from the...
  42. Thread: burn out!

    by sammy37
    Replies
    25
    Views
    1,674

    Anythings possible, it may have heated up or...

    Anythings possible, it may have heated up or melted in hidden areas when everything shorted out.
  43. Thread: burn out!

    by sammy37
    Replies
    25
    Views
    1,674

    I would ask for new thermostat wire also

    I would ask for new thermostat wire also
  44. Thread: burn out!

    by sammy37
    Replies
    25
    Views
    1,674

    Thats exactly what I said in the beginning and...

    Thats exactly what I said in the beginning and you're very lucky you only lost a couple boards and thermostat, could have been the whole house.
  45. Thread: burn out!

    by sammy37
    Replies
    25
    Views
    1,674

    That still doesn't explain why things fried,...

    That still doesn't explain why things fried, still gotta be something else screwed up.
  46. Thread: burn out!

    by sammy37
    Replies
    25
    Views
    1,674

    No contractor in his right mind, could honestly...

    No contractor in his right mind, could honestly think that your problem would be caused by a slightly undersized line circuit to a condensor. Sounds to me like a low voltage wire got in contact with...
  47. Kinda makes you wonder how some of these guys...

    Kinda makes you wonder how some of these guys even make it.
  48. Good deal, glad it's fixed.

    Good deal, glad it's fixed.
  49. Replies
    4
    Views
    599

    I think the idea of having a packaged heat pump...

    I think the idea of having a packaged heat pump or gas pack on a mobile home makes sense.
    I find the noise level of having the whole mess outside, is much more tolerable than what usually comes...
  50. Replies
    6
    Views
    1,790

    Any brand package unit, properly sized, installed...

    Any brand package unit, properly sized, installed and maintained, will last at least 15 years.
    Find a good contractor and go for it.
Results 1 to 50 of 755