    Does anyone know anything about this company, I got a job offer from them? The offer is for a service tech. position. Any info is very appreciated.
  2. If you are asking is there something you can do...

    If you are asking is there something you can do to make your non wifi tstats wifi, I don't know of anything you can do other than buy the wifi stats. We have had customers that have a non wifi and...
  3. Replies
    5
    Views
    998

    Normally if a t stat says its in emergency heat...

    Normally if a t stat says its in emergency heat it has to be set up as a heat pump a straight air with furnace would not have e heat
  4. Thread: im in love

    by Slayer0901
    Replies
    11
    Views
    1,387

    Is the H10pm or the H10g better or is the only...

    Is the H10pm or the H10g better or is the only difference the battery?
  5. Thread: im in love

    by Slayer0901
    Replies
    11
    Views
    1,387

    I have an inficon also it is good for one thing...

    I have an inficon also it is good for one thing in my experience , throwing it at a brick wall when you get pi$$ed because you can't find the leak. I will say that it is a lot better at finding 22...
  6. Replies
    47
    Views
    6,187

    Ok I'll be going back to each one but it will...

    Ok I'll be going back to each one but it will probably be a few days, we are covered up with no air calls right now but I appreciate that.
  7. Replies
    47
    Views
    6,187

    I'm not sure about the dry charge without going...

    I'm not sure about the dry charge without going back and looking at the rating plate. We normally set carrier and Payne units and most do have txv inside, but not all it just depends on the seer...
  8. Replies
    47
    Views
    6,187

    Yes I am using old coils , why put in dry charge...

    Yes I am using old coils , why put in dry charge if you are going to install new coil? When I read SBKold's post that told me why I am having to add refrigerant, he is right I haven't changed the...
  9. Replies
    47
    Views
    6,187

    Thanks I haven't thought about it, and to be...

    Thanks I haven't thought about it, and to be honest all I've worked with has been in cool mode, that's why I like coming on here, always , always more to learn and sometimes things you already know...
  10. Replies
    47
    Views
    6,187

    The dry charge units I have installed has all...

    The dry charge units I have installed has all been Payne all of them have said a weight to charge in to them. I have purged nightrogen in all of them, removed old and installed new liquid line filter...
  11. Replies
    47
    Views
    6,187

    [QUOTE=VTP99;13182431] I don't know what you...

    I don't know what you mean by squillion changed to slayer? I posted a quick reply just like I have before.
  12. Replies
    47
    Views
    6,187

    All I am saying is that in my opinion that is the...

    All I am saying is that in my opinion that is the best way to get the correct amount of charge in the unit, the ones I have installed when I weigh in the amount it calls for it is still under charged.
  13. Replies
    47
    Views
    6,187

    I don't know where you are seeing that I ever...

    I don't know where you are seeing that I ever said that I haven't installed a dry charge unit . I agree with the next poster,I do weigh in amount called for and then switch to superheat charging .
  14. Replies
    47
    Views
    6,187

    In my experience every dry charge unit that I put...

    In my experience every dry charge unit that I put in I had to charge it by superheat, when I weighed in the amount that it says on data plate there still wasn't enough charge in the unit.
  15. Replies
    21
    Views
    2,759

    I caught it while it wasn't lighting and had my...

    I caught it while it wasn't lighting and had my manometer on the outlet side going into burners and I had 3.47"wc.
  16. Replies
    21
    Views
    2,759

    It ohmed out at 52.5

    It ohmed out at 52.5
  17. Replies
    21
    Views
    2,759

    I ohmed out hot surface ignitor I did not amp it...

    I ohmed out hot surface ignitor I did not amp it honestly don't know what amp one should be. It is in a crawl space with fresh air vents on all sides of crawl space,I did get on roof and look at...
  18. Replies
    21
    Views
    2,759

    Need gas furnace help

    Im working on an amanna gas furnace the problem is sometimes furnace will not light when I get there the only thing running is the inducer fan all pressure switches and limits have always been closed...
  19. Replies
    16
    Views
    3,797

    I love the fact that they got the furnace trap...

    I love the fact that they got the furnace trap out of in front of the blower but why not make it clear on both sides instead of just on the inward side and I also like no burner box now u don't have...
  20. Some times when u install a new board or variable...

    Some times when u install a new board or variable speed blower the infinity stat will recognize it and sometimes it will not then u have to go in advanced menu and go to install then manually tell...
  21. Replies
    34
    Views
    4,382

    I agree what u do to one side it will affect the...

    I agree what u do to one side it will affect the other side
  22. Replies
    34
    Views
    4,382

    Your subcool tells you if u have enough...

    Your subcool tells you if u have enough refrigerant in system your superheat tells u if your txv is metering correctly
  23. Thanks for posting this I haven't heard about it...

    Thanks for posting this I haven't heard about it I just signed also
  24. Replies
    47
    Views
    4,397

    We get people that call our office wanting us to...

    We get people that call our office wanting us to install a unit that they bought online and we won't even consider it any more we had a customer that bought a 5ton package unit online to install at...
  25. Replies
    29
    Views
    2,553

    My company installs carrier and Payne units and...

    My company installs carrier and Payne units and their dryers also come with the condensing unit but we put our dryer inside near evaporator I was always taught it was so that the dryer will not rust...
  26. Replies
    14
    Views
    2,268

    I love my sman gauges also I only use them on 410...

    I love my sman gauges also I only use them on 410 units I still use my regular gauges for r-22
  27. Remove temp sensor bulb and warm it up while in...

    Remove temp sensor bulb and warm it up while in cool mode and see if low side pressures go up if not txv is bad sometimes u can just replace bulb and it will be fine
  28. If it works fine in heat mode and then in cool...

    If it works fine in heat mode and then in cool mode low side is low and hige side is fine then u add refrigerant and high sie goes up but low side stays the same indoor txv is not metering correctly.
  29. Replies
    9
    Views
    763

    Defiantly replace line set you willbe going...

    Defiantly replace line set you willbe going fromr-22 to 410- a
  30. Replies
    104
    Views
    24,978

    I always weigh in charge but if just adding to...

    I always weigh in charge but if just adding to system I charge by sub cooling and then check superheat to make sure my metering device is metering correctly but in the real world if not sized...
  31. Replies
    23
    Views
    2,092

    I went to a class on these furnaces last week the...

    I went to a class on these furnaces last week the reason for the screws is for better mixing of the gas and air before ignition:
Results 1 to 31 of 57