    kfc

    well I have been getting a lot of everythings,, mostly cooler this past week, the owners of of franchase want a pm program but,, I don't have time. as for Micro-waves my boss always tells me just...
  2. Replies
    4
    Views
    775

    well I haven't had any more problems with the...

    well I haven't had any more problems with the ignition module, I did addd the flue extension as per the factory, but I also had found out from other contractors that they were having problems with...
  3. Replies
    13
    Views
    2,378

    KFC microwaves

    yep got to love those Amanas, KFC use's 3 the KFC1 , KFC 2 and the RPSk9, I work for the KFC so Iget to see them lots, but they really don't break down all to often,, have more problems with deep...
  4. Replies
    4
    Views
    775

    yep appox 26 volts to the ignition module and 26...

    yep appox 26 volts to the ignition module and 26 volts out to the gas vale, it just isn't sparking, replace module and its fine for a while and then same problem all over, I will discuss itwith...
  5. Replies
    4
    Views
    775

    Ignition problems

    I am looking to see if any one else is having a problem with ignition modues.
    I am working on a Carrier 48DJE009520, serial number 4491G4300. The problem is it has gone through 4 ignition modules in...
  6. Replies
    12
    Views
    1,798

    I found a new web site today lots of help,...

    I found a new web site today lots of help, amnuals and such
    WWW.ckps.com
  7. Replies
    12
    Views
    1,798

    Ice makers

    I have een to my wholesalers for the Manitowoc and to the Hoshizaki one day, both helped some.
  8. Replies
    12
    Views
    1,798

    training

    I have been to the Frymaster one day training it was presented by a local supplier, I have been to a Amana 1/2 day seminar, most of those can be found buy calling appliance wholesalers, I also went...
  9. I ran a service company for 3 and halfs years,...

    I ran a service company for 3 and halfs years, worked on all kitchen equipment, it is greaasy messy, but I enjoy the challenge. I left that and now work for KFC, I do all the HVAC/r and kitchen...
  10. Thread: Cheap

    by dmp3_16hvac/r
    Replies
    2
    Views
    1,274

    if the gas valve does not repond and close and...

    if the gas valve does not repond and close and they have had problems with the knob replace the valve the next thing that can happen is for the gas valve to start on fire or bolw up.
  11. Replies
    15
    Views
    1,713

    those flakers need to be cleaned every couple of...

    those flakers need to be cleaned every couple of months, they do not like any build up in the ice barrel or water system
  12. Carrier

    or you try Auer steel in MIlwaukee they may have someone they can reccomend in the Mad town area
  13. Replies
    2
    Views
    811

    more information

    the unit is a Trane YCD120B3H0AA, I returned today and it is running fine,,
    stil have no idea, neither does Trane as to why the other board blew up.
  14. Replies
    2
    Views
    811

    A question for all you out there I was working on...

    A question for all you out there I was working on a trane rooftop,, the main board which contorls everything had the corner where the heat relay totally blown out,, checked everything couldn't find a...
  15. Thread: parts

    by dmp3_16hvac/r
    Replies
    6
    Views
    1,514

    FMP is good for parts, there is also PArts Town,...

    FMP is good for parts, there is also PArts Town, COnsolidated only sells to repair contractors who resell them them,
  16. Replies
    12
    Views
    2,370

    I work for KFC,, we have started using DUKE...

    I work for KFC,, we have started using DUKE holding trays, I have done work on them before didn't care for the way you have to disassemdle them to replace the heater, would like to be able to use the...
  17. Replies
    6
    Views
    1,275

    yes you have to love all the grease in the Henny...

    yes you have to love all the grease in the Henny Penny fryers, it just hangs and waits for the right moment to drop on your head, the steam works pretty good but it does make a drippy mess under it.
  18. Replies
    21
    Views
    2,931

    is the motor turning in the right direction if it...

    is the motor turning in the right direction if it is running wrong you can draw high amps, but move little air, you need to know direction of fan.
  19. Replies
    3
    Views
    1,481

    one thing I have found the terminals will burn...

    one thing I have found the terminals will burn off if they are not crimped tight, and the wire has to be clean before you crimp it.
  20. I think it is great as I have 10 years doing...

    I think it is great as I have 10 years doing commerical cooking equipment and 20 doing HVAC, they do get put togather sometimes
  21. Thread: carrier

    by dmp3_16hvac/r
    Replies
    11
    Views
    993

    I have had some units due that, i found that the...

    I have had some units due that, i found that the contact was drawing excessive amps,, in my case the fuse was 3 amps and it draw 3.7 causing it to trip.
  22. Replies
    8
    Views
    1,151

    removal of R410a needs to be done in a liquid...

    removal of R410a needs to be done in a liquid state, R22 can be done as a gas. most of the new compound refrigerants need to be removed in a liquis stae as much as you can, otherwise you change the...
  23. Replies
    10
    Views
    907

    Good Luck in your new direction, as someone who...

    Good Luck in your new direction, as someone who has been my own boss, I gave it up. Family meant more to me. I Ran 24/7/365 for 15 years, missed a lot of family time, every holiday you have calls,...
  24. Replies
    10
    Views
    757

    check the rotation of the blower, if the unit is...

    check the rotation of the blower, if the unit is running wrong it will have high amp draw, it will still move a little air. is this a circle type up draf exhaust? if it is the direction is usually...
  25. Replies
    15
    Views
    3,515

    those fryers are always fun to work on once the...

    those fryers are always fun to work on once the grease gells, exspecially around switchs, we have them where there is 2-3 inches of grease, that once you touch it sticks to everything. got to love...
  26. Replies
    11
    Views
    1,702

    I think it is ood, if you ecover the freon with a...

    I think it is ood, if you ecover the freon with a filter before your recovery machine, and install new filter/driers you should be able to use the freon again unless there was a major burnout. in...
  27. Drain blaster

    Hey payson
    you had said in a post a whie ago that you made a nozzle for cleaning coils, could you post a picture of it. the drain blaster works great, but a nozzle to spray yellow death would be...
  28. Replies
    6
    Views
    2,042

    looks like some of my roofs, except for I didn't...

    looks like some of my roofs, except for I didn't see any chicken bones.
  29. Replies
    13
    Views
    1,726

    How about Jackson Browne,,,,,, saw him live at a...

    How about Jackson Browne,,,,,, saw him live at a benifit concert last year, it was great, going back again, got some pics of him from the foot of the stage.
  30. Replies
    11
    Views
    1,748

    It sounds like the compressor may have died, and...

    It sounds like the compressor may have died, and shirted out, hard to really tel unless you see it inperson, and trace the wires around.
  31. Replies
    2
    Views
    694

    I have worked in serveral different areas, you...

    I have worked in serveral different areas, you can always look to the chain type resturants, in the Milwaukee area they have started to go to hiring a tech to do there work, you can gain lots of...
  32. in the resturant chain I work for I have t-stats...

    in the resturant chain I work for I have t-stats mounted in the open for the employees to change they think they are doing something when it isn't even hooked up. its the mind thing if they think...
  33. Thread: Gas Leak

    by dmp3_16hvac/r
    Replies
    27
    Views
    6,751

    need to get a cordless sawzall it is the best

    need to get a cordless sawzall it is the best
  34. good luck with the new oppuntunity, I left my...

    good luck with the new oppuntunity, I left my last job with no notice, actually while i was in a disciplanry meeting I called my currrent employer, and had the the job before they had fired me. they...
  35. Well at least the guy made sure the gas pipes...

    Well at least the guy made sure the gas pipes won't leak, must be enough dope on there for 10 units, is the gas line designed to be moveable when ever you service the unit, is there any kind of...
  36. Replies
    24
    Views
    1,852

    the system holds appox 9 lbs, but when it gts to...

    the system holds appox 9 lbs, but when it gts to 4 to 5 lbs it starts to effect the freeze, I am not to impressed with the dye to locate leaks. the one didn't have any dye to it, as I was informed...
  37. Hey Payson,, not really about this thread,,...

    Hey Payson,,


    not really about this thread,, but I was trying to find the directions to build your air powered sprayer gun,,

    thanks, so hows the new company better then the last,, hope so
  38. Replies
    24
    Views
    1,852

    Hello to all well I took the day to work on...

    Hello to all

    well I took the day to work on the freezer, lots of good ideas, I rechecked with the dye, and bubbles and electronic. I looked at the low pressure switch, and it sen the electronic...
  39. Replies
    24
    Views
    1,852

    I added the dye last Friday and went to check on...

    I added the dye last Friday and went to check on Tuesday following, I a going back tomorrow, I am going to check all the tubing, remove all the insulation, if i don't find the dye then I guess I...
  40. Replies
    24
    Views
    1,852

    I am working on a International Cold storage walk...

    I am working on a International Cold storage walk in frezzer, it has HP-80, the line set is about 10 feet long, the problem is it has a leak, I have used a electronic detector, bubble, and recently I...
  41. Replies
    19
    Views
    6,357

    Hosi makes a really good ice machine cleaner, but...

    Hosi makes a really good ice machine cleaner, but it is not safe on Manito's, unless you use lots of care and rense it real quick, it makes quick work of all the slime on the tube. but it can eat...
  42. Replies
    6
    Views
    1,437

    WOW that is pretty clean compared to the ones by...

    WOW that is pretty clean compared to the ones by me, ours get caked up with flour and grease, and then they want me to do PM's on them 35 as of now, along with 35 RTU's,, maybe I need some help.
  43. Replies
    8
    Views
    1,960

    thats not to bad, I work for a resturant chain...

    thats not to bad, I work for a resturant chain and you would be amased on so of the stuff that is on equipment,
  44. Replies
    25
    Views
    2,293

    Those are the test pressures, you should be...

    Those are the test pressures, you should be looking for about 45 to 60 suction and discharge depends on if it is water cooled, or air, air should be around 150 to 175
  45. Is it for the better

    Well Payson

    its good to see you have decieded to better your self the best of good luck to you. I will miss your posting, but hopefully you will still have some fun adventures to come. Good Luck...
  46. Replies
    10
    Views
    8,364

    the octopus is a convert,,, I had to remove one...

    the octopus is a convert,,, I had to remove one of those once burned out my sawzall cutting it up
  47. I like the picture with him bending over at the...

    I like the picture with him bending over at the stairs,, nice sharp corner to bite you in the back.
  48. Replies
    16
    Views
    3,157

    well it is only worth any thing when someone...

    well it is only worth any thing when someone wnats to buy it, I do have serveral 30lb drums of R12 from when it was .07 a pound,,,,
  49. Replies
    15
    Views
    3,028

    Well at least it is coiled nicely, really smooth...

    Well at least it is coiled nicely, really smooth radis
  50. Thread: 3

    by dmp3_16hvac/r
    Replies
    16
    Views
    2,396

    I looked at one of those too replace our...

    I looked at one of those too replace our Chev3500, but if you short it is hard to getb the ladders off the roof