  1. This is about the user access level, check the UA...

    This is about the user access level, check the UA point for your login,
    you may be able to modify the UA point to get 'access' to the point type there.
    If you cannot modify it then you will need a...
  2. Try logging in with newpanel/setup . No, any of...

    Try logging in with newpanel/setup . No, any of those models have not been available for some years.
  3. Replies
    20
    Views
    4,282

    Have 400+ installed, work great, good tech...

    Have 400+ installed, work great, good tech support, continuing development,
    and has all the bells and whistles i wanted..
  4. Replies
    18
    Views
    2,620

    autocad and excel !

    autocad and excel !
  5. yes, this is the typical vav SOO(sequence of...

    yes, this is the typical vav SOO(sequence of operation) ,use for the last 100 years, calls for delivering constant temp air to all the zones,, all the time
    hehe

    sounds like a vav single zone with...
  6. wireless or wired?

    wireless or wired?
  7. Replies
    10
    Views
    1,074

    Yes thats a typical method that has been used....

    Yes thats a typical method that has been used.
    but 1.5"wc return plenum static seems high to me
    more like 0.5"wc unless there is considerable distance between the fans..

    you control the relief...
  8. Replies
    3
    Views
    1,825

    Energy savings from 10% to 30% are usual from a...

    Energy savings from 10% to 30% are usual from a DDC install. Setpoint control (better Source-Load matching), reduction of simultaneious heating and cooling and scheduling gives you most of the bang,...
  9. Replies
    2
    Views
    765

    i may be able to help you. Drop me an email, in...

    i may be able to help you. Drop me an email, in profile.
  10. Replies
    9
    Views
    1,943

    yep, you need to flag each point you want to have...

    yep, you need to flag each point you want to have visible on the IP network...
    but you need the controller configuration software, Edifice to do so.
    its on the second tab marked setup... :)
    the...
  11. Replies
    20
    Views
    4,282

    If they are older than 2 years than not likely...

    If they are older than 2 years than not likely Bacnet.
    Firmware has to be specifically Bacnet version.. is upgradeable depending on hardware version of course..
    configuration software is doggled...
  12. Replies
    27
    Views
    2,265

    Pick one of the good guys, like Delta or Alerton...

    Pick one of the good guys, like Delta or Alerton or xxxxxxx (can i say that ! :angel:)
    someone with a nice Bacnet OWS front end that you can live with..
    get one of their smallest system controllers...
  13. Replies
    11
    Views
    2,801

    Floating/digital is the poor mans option. Use...

    Floating/digital is the poor mans option.
    Use the Mod/Analog if you can.
    Get the position feedback option too if you can use/see it.

    it often is more of a function of what your connecting it too...
  14. Replies
    15
    Views
    1,203

    so if they did burn the house down.. could they...

    so if they did burn the house down..
    could they sue you for malpractice?
  15. Replies
    14
    Views
    1,763

    I remember using N to pressurize lines while...

    I remember using N to pressurize lines while brazing to prohibit scale and oxidation of the copper during brazing. not sure what moisture has to do with it. Its the O thats corrosive..
    as far as...
  16. I sold Adam and Eve the first Rheem! :hijacked:...

    I sold Adam and Eve the first Rheem!
    :hijacked:
    :cheers:
  17. Replies
    10
    Views
    858

    There are a few settings in the DSC that could be...

    There are a few settings in the DSC that could be impacting things..
    You can set the APDU timeout and retries, mstp max masters, and the type
    of data exchange for each point. Could be something...
  18. Replies
    8
    Views
    1,769

    The concept is intriguing though. an algorithm...

    The concept is intriguing though.
    an algorithm to adjust the algorithm that adjusts the ,, algorithm.

    adaptive....
    at some point in time, it became apparent that 'normal or constant' control...
  19. Replies
    3
    Views
    1,426

    its all over the net, just search for it. ...

    its all over the net, just search for it.

    Logical Analog Input (LAI)
    Logical Analog Output (LAO)
    Logical Digital Input (LDI)
    Logical Digital Output (LDO)
    Logical Fast/Slow/Stop Latched...
  20. Replies
    7
    Views
    1,356

    Doesn't sound like you missed anything, you...

    Doesn't sound like you missed anything,
    you likely just have a doggle that no do Illustrator.
    321-E early ethenet key..

    i'v got a keychecker progm that might help if you could update your...
  21. so you fixed it. obviously the velocity...

    so you fixed it.

    obviously the velocity controller..
    many of those must have a velociy pressure of some sort to function at all.
    check the vp probe with a mag or water gage, also check the...
  22. Teletrol- GPL & XML line code Cylon- GPL ...

    Teletrol- GPL & XML line code

    Cylon- GPL


    imho, they all should have just stuck with Basic
    its the easiest to understand and has enough flexiblity to do just about anything one would want in...
  23. Replies
    14
    Views
    2,437

    it is all about power eventually it has to be...

    it is all about power

    eventually it has to be a lower cost vav controller and room sensor.
    one would think that someone would have a one wire solution already, power + comm .. i mean we've had...
  24. Replies
    17
    Views
    1,700

    yep, it is about our freedoms. she got it right,...

    yep, it is about our freedoms. she got it right, we are being reamed.
    must of been a subconcious slipup thing..
  25. Whynot.. yes i would agree, all energy efficient...

    Whynot..
    yes i would agree, all energy efficient control strategies use some kind of realtime reset to accomplish increased comfort and energy reduction.

    the original question was



    so...
  26. Replies
    5
    Views
    1,207

    VAV4 V5.1, is the firmware, and was the last...

    VAV4 V5.1, is the firmware, and was the last version made for the proprietary V2 VAV controllers, 1999, was likely an IZ (Intellizone) product which ended in 98-99 when they released the bacnet...
  27. Replies
    74
    Views
    7,531

    A:det: Must be an excellent control system!! lol...

    A:det:
    Must be an excellent control system!! lol
    Was offline,default values..

    B:det:
    Yes, Roof top units. that was/is the entire bulding, and agreed, i try to use
    keys for a piece that is...
  28. I'm not sure either, i do recall some central...

    I'm not sure either,
    i do recall some central plant awhile back.
    they would start up the cooling early depending on what the load looked like it would be that day. it was an undersized system and...
  29. It sounds like he is expecting the optimization...

    It sounds like he is expecting the optimization of equipment start and stop. So if you can get advanced temperature or 'forecast' data you can determin if one may stop the cooling a little earlier...
  30. Replies
    19
    Views
    1,710

    :eek2: It sounds like you are saying the range...

    :eek2:

    It sounds like you are saying the range is off when you calibrate the sensor..
    which may be true, part of calibration would be adjusting the curve..
    even if it is likely sensor placement...
  31. Replies
    74
    Views
    7,531

    flrpln/mouseovr/w/znoffset One of my...

    flrpln/mouseovr/w/znoffset


    One of my favorites i think,

    Mouseover highligts the Zone 'area' served

    Zone temp is in box

    Zone temp offset is color in box
  32. Replies
    74
    Views
    7,531

    Floor plans have a purpose to show the zones...

    Floor plans have a purpose
    to show the zones
    this is essentially its only use,
    but there is no other better way to represent this data, that i can think of.
    it is usually the last thing done on a...
  33. Replies
    17
    Views
    1,076

    in colder climates this design would be...

    in colder climates this design would be difficult. it is likely even with minimum air for ventilation that the mixed air to the boxes is below what can be reheated to the space. and the interior/core...
  34. Replies
    17
    Views
    1,076

    yea, the filter should help. you'll get more air...

    yea, the filter should help. you'll get more air from the primary ducting.
    but have him add a speed control for the fan in the box too. then you
    can give the control guy another output and the...
  35. Replies
    3
    Views
    888

    CTL Temp would be the calculated setpoint , room...

    CTL Temp would be the calculated setpoint , room temp is obviously the phsical point.
    DualDuct, heating and cooling, two setpoints, some sort of deadband and the control
    point lives in the middle..
  36. Replies
    14
    Views
    2,827

    why independent is better. There is no better...

    why independent is better.

    There is no better in this comparison.

    It isn't a Chevy vs. Ford thing..

    more like a Mercedes vs. Kia thing,..

    There is only proper application and improper...
  37. Replies
    12
    Views
    769

    errrs..... should be.. substitute a var...

    errrs.....

    should be..
    substitute a var FireRate for the Boiler 1 Fire Rate in the Scale statement..

    var FireRate

    Do Every 30s
    If FireRate>Boiler 1 Fire Rate +0.2 then
    Boiler 1 Fire...
  38. Replies
    12
    Views
    769

    Cold Start: Depends on what other sensors or...

    Cold Start:
    Depends on what other sensors or control you may have.
    and what the problems on startup may be, type of equipment, type of load,

    Often on start a boiler will be cold and have only...
  39. Replies
    12
    Views
    769

    yes it was just an arbitrary choice, which from a...

    yes it was just an arbitrary choice, which from a user standpoint probably not
    a good idea, as they wouldn't know... just one STPT may be a good idea..
    add
    Boiler 1 Modulating STPT = Boiler 1 STPT...
  40. Replies
    12
    Views
    769

    And as long as we don't have any thing to do...

    And as long as we don't have any thing to do today, why not just use 2 lines... ;)

    'Boiler 1 Fire rate' = Scale ( 'WK Boiler 1 Pressure' ,0,1,100,'Boiler 1 Modulating STPT',45)
    Switch( 'Boiler 1...
  41. Replies
    12
    Views
    769

    There is of course, a better way ;) 'Boiler 1...

    There is of course, a better way ;)

    'Boiler 1 Fire rate' = Scale ( 'WK Boiler 1 Pressure' ,0,1,100,'Boiler 1 Modulating STPT',45)
    If ('WK Boiler 1 Pressure' < 'Boiler 1 Cycling STPT'-1) Then
    ...
  42. Replies
    12
    Views
    769

    On further look the logic isn't quite right, I...

    On further look the logic isn't quite right,
    I think you want the Boiler 1 Modulating STPT' to be the fire rate control..
    not the 'Boiler 1 Cycling STPT'
    And the order of the ElseIf is incorrect....
  43. Replies
    12
    Views
    769

    Hi, Loaded your pg and it didn't show a fault....

    Hi,

    Loaded your pg and it didn't show a fault.
    Logic looks ok, ..
    Tested it and it worked!
    What you see as the problem Z?