  1. I recently had a site that had this issue, but...

    I recently had a site that had this issue, but JCI couldn't auto discover the devices. I had to go to each TEC and make them all masters on the PXC. This was the only way that JCI could see them.
  2. Here is a very basic air handler that I used in a...

    Here is a very basic air handler that I used in a class. 464071
  3. Replies
    2
    Views
    277

    From what you have said you had the software...

    From what you have said you had the software installed so you should have it still. In your title the first thing that you mention is the DX-9100. The software that you want doesn't really do...
  4. Thread: NAE Problem

    by NickDeal
    Replies
    14
    Views
    789

    I think I remember a flash sheet from many years...

    I think I remember a flash sheet from many years ago saying there was an issue with the SecurityDB xml file getting deleted. You should be able to copy the securityDB from your laptop if you have SCT...
  5. Replies
    4
    Views
    336

    It could be from anything. Writing to a read only...

    It could be from anything. Writing to a read only attribute is only one cause of errors. You could be getting bad CRC headers on the token frames. I would run a diagnostic on the bus. If that comes...
  6. Thread: JCI CCT

    by NickDeal
    Replies
    6
    Views
    414

    It sounds like there should be a sequencer in the...

    It sounds like there should be a sequencer in the program to stage the compressors on with the ramping of the PID loop. Check to see if there is such a block. If the tech that installed the system...
  7. Replies
    4
    Views
    336

    This references the number of error that the NAE...

    This references the number of error that the NAE has received. There could be many reasons for this an example is trying to write to a read only attribute. I doubt you will have an issue with the NAE...
  8. Replies
    29
    Views
    2,508

    I don't really think this is an issue with the...

    I don't really think this is an issue with the NAE itself. Looking at your screenshots you don't have that many graphics or objects. The main problem is the software version that you are using. 2.0...
  9. Replies
    10
    Views
    754

    You cannot setup the lon bus in the NAE. JCI uses...

    You cannot setup the lon bus in the NAE. JCI uses LN Builder to build the lon trunk with the NAE on it. You have to commission the NAE into LN Builder to get it read the other devices on the trunk....
  10. Replies
    6
    Views
    551

    You are correct. The NAEs talk using SOAP...

    You are correct. The NAEs talk using SOAP connections to the ADX. Depending on how many NAEs you have you can change the site to output BACnet points that can be integrated to Tridium. However I...
  11. Replies
    3
    Views
    693

    If you have different versions of SQL Server on...

    If you have different versions of SQL Server on the machines you will get this error. For instance if on the server you have SQL 2008 and on your machine you have SQL 2005 you won't be able to...
  12. Replies
    3
    Views
    407

    If you are online to the NAE you just save and...

    If you are online to the NAE you just save and it'll activate. If you are in SCT you will have to download.
  13. Replies
    3
    Views
    407

    Those are for using a Control System within a...

    Those are for using a Control System within a control system. You can insert a LCT object into another LCT object to segregate some of the process. The arrows are for the inputs and outputs of those...
  14. Replies
    7
    Views
    1,130

    You can change calibration offsets using the...

    You can change calibration offsets using the Engineering view on the Metasys frontend. If you login and double click an NAE under the Engineering tab you can discover all the points in the controller...
  15. Replies
    4
    Views
    1,372

    Do input is less than 90 and input is greater...

    Do input is less than 90 and input is greater than 55.

    So you would use X<Y where X is your input and Y is a constant of 90.
    Then use X>Y where Xis the input and Y is a constant of 55.
    Then add...
  16. Replies
    10
    Views
    1,597

    You need to have SCT installed on your laptop to...

    You need to have SCT installed on your laptop to do passthru.
  17. Replies
    9
    Views
    1,265

    These are not generally available to the public....

    These are not generally available to the public. They are almost always issues as a flash sheet to JCI personnel. I'm not sure if the ABCS get the flash sheets.
  18. Replies
    9
    Views
    1,265

    What version are you working with? There are...

    What version are you working with? There are several versions of Metasys that have memory leak problems that will cause the NAEs to reboot. Also at v4 there was a patch that was required to NAE35/45s...
  19. Replies
    15
    Views
    1,645

    It might get complicated if you are not able get...

    It might get complicated if you are not able get a hold of LN-Builder or something similar. You would have to weigh cost ratios. It might be cheaper to get LN-Builder and do the integration directly....
  20. Replies
    15
    Views
    1,645

    In addition to the device specific resource...

    In addition to the device specific resource files, the LONWORKS Integration object
    requires the STANDARD.TYP and STANDARD.FPT resource files, and a
    NVConfig.dat file. This NVConfig.dat file is...
  21. Replies
    15
    Views
    1,645

    You will need LN-Builder to put the Trane units...

    You will need LN-Builder to put the Trane units on the same subsystem as the other units and the NAE. I have integrated these units to NAEs before and was unable to to it without LN-Builder or some...
  22. Replies
    15
    Views
    1,645

    In my opinion they are a real pain in the butt....

    In my opinion they are a real pain in the butt. First make sure you have the original LN-Builder database. Assuming JCI installed the first set. If you don't you will need to build one with all the...
  23. Replies
    30
    Views
    3,579

    They have never been synced. They are supposed to...

    They have never been synced. They are supposed to sync every hour using windows time sync, but they never have been on time. This causes issues with the time stamps for the trends. I am going to test...
  24. Replies
    30
    Views
    3,579

    This program runs great. I have a site with over...

    This program runs great. I have a site with over 40 JCI NAEs that have time sync issues and this works great. Is there a way to get your source code or make it get the time on the system that it is...
  25. Ok, so I am confused. Are you trying to send...

    Ok, so I am confused. Are you trying to send trend data to an NAE or get trend data from an NAE? If your NAE is a supervisory device then it really shouldn't be receiving a lot of data from other...
Results 1 to 25 of 122
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event