Search:

Type: Posts; User: dunkman

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    17
    Views
    2,046

    Oh YES! My favorite! Now that'll keep you busy...

    Oh YES! My favorite! Now that'll keep you busy for while.
  2. Replies
    13
    Views
    1,060

    Don't worry about it. Those were superceded to...

    Don't worry about it. Those were superceded to the new .10" rating months ago. Some of the old ones were .18" some were .15" they all get a .10" now.
  3. Thread: Trusteam!!!

    by dunkman
    Replies
    16
    Views
    979

    Why not 12 gallon units?

    Why not 12 gallon units?
  4. Try having 3 new Hydron units in the same job...

    Try having 3 new Hydron units in the same job that had bad reversing valves. They sent 3 new valves, all of which also failed within days. We had to build up sil-fos on the reversing valve pilot...
  5. Replies
    13
    Views
    1,926

    I've seen this happen when the wires going to the...

    I've seen this happen when the wires going to the economizer plug were squished between the blower housing and the top of the unit, rubbing through the common 24v wire. That'll make all the...
  6. Replies
    51
    Views
    6,072

    Ha! Aren't they all???

    Ha! Aren't they all???
  7. LIEBERTS! Why didn't somebody say that before?...

    LIEBERTS! Why didn't somebody say that before? Now I just feel silly. We have a bunch of those around here, none are ducted units though.

    Total of 15 tons, I wonder if you're short on capacity....
  8. Forgive me, I'm trying to understand. Do you mean...

    Forgive me, I'm trying to understand. Do you mean the sensor is in the exhaust of the servers, or by "exhaust ducts" do you mean the cold air supplies?

    BTW, what's a Challenger?
  9. Replies
    51
    Views
    6,072

    Thank you for this thread, it's been educational.

    Thank you for this thread, it's been educational.
  10. Actually the new cabinets are pretty tight. Also...

    Actually the new cabinets are pretty tight. Also insulated better than the old metal ones, less problems with condensation on the cabinet.
  11. So it senses the same temperature that operates...

    So it senses the same temperature that operates the cooling equipment.

    Where is the thermostat now?
  12. I would have the sensor next to the cooling...

    I would have the sensor next to the cooling thermostat.
  13. Replies
    49
    Views
    7,090

    All I've ever done with these systems is connect...

    All I've ever done with these systems is connect with hyperterminal through the N30 to manage settings, check sensors, etc. I wouldn't mind knowing how to fix program issues on the UNT controllers.
  14. You talking about a City Multi? Try a search on...

    You talking about a City Multi? Try a search on that.
  15. Replies
    23
    Views
    1,918

    I just checked with myself, and myself concurs...

    I just checked with myself, and myself concurs that i use the same manifold on everything. Just be sure to purge the liquid from your high side hose back into each system before removing.

    Then...
  16. Replies
    13
    Views
    2,336

    What does it do if you plug your hoses and hook...

    What does it do if you plug your hoses and hook it up to the vac pump?

    With both hi & lo side open pressure up with some nitrogen and watch to see if both transducers read the same as you fill it...
  17. Your tech needs to focus on the indoor blower...

    Your tech needs to focus on the indoor blower motor and low voltage wire connections .
  18. Replies
    9
    Views
    1,461

    Those numbers seem kindof weird, maybe get an...

    Those numbers seem kindof weird, maybe get an opinion from another meter? You should also check the CC heater to ground, if it has one. Also check each winding to ground.

    BTW to address your...
  19. Replies
    13
    Views
    1,489

    I would definately have a blower door test done...

    I would definately have a blower door test done on this house to see how leaky it is.
  20. It's a ball valve.

    It's a ball valve.
  21. Replies
    12
    Views
    2,513

    Maybe dirty? Or maybe it could possibly be...

    Maybe dirty?


    Or maybe it could possibly be slightly miss matched all to hell!
  22. 10 deg delta is too low on 1st stage. I wonder if...

    10 deg delta is too low on 1st stage. I wonder if your fan is set up right? WHen you set the stat to fan on, then put on 1st stage cooling, is there a difference in the fan speed? It should remain at...
  23. Thread: Manifold hoses

    by dunkman
    Replies
    24
    Views
    2,053

    I do a lot of 410a. I just blew another lowloss...

    I do a lot of 410a. I just blew another lowloss on the high side. Just have to rebuild em every 2 months in the summer. Oh yeah, summer's only 3 months here anyway... I like the lowloss, they don't...
  24. Personally, I have an TUH2B060 with a 2 ton a/c....

    Personally, I have an TUH2B060 with a 2 ton a/c. I run it at 50% continuous, 2.5 ton airflow, comfort-R on. I do it that way to get a little more sensible cooling, since I have to run a stand alone...
  25. Replies
    21
    Views
    2,213

    I didn't mean that you were necessarily...

    I didn't mean that you were necessarily undercharged in your case. Just sharing general knowledge. You can tell what your condensor efficiency is by the liq line temp-oat (approach temp)