  1. Replies
    4
    Views
    185

    So you have had luck adding custom enum to Bacnet...

    So you have had luck adding custom enum to Bacnet Spyders input/outputs? Anytime I try to use custom enums to network inputs/outputs on Bacnet spyders.....I get the following error.

    482611

    I...
  2. What version of DX9100's? On higher versions you...

    What version of DX9100's? On higher versions you can do this via network inputs and outputs.
  3. Thread: Carrier Ivu

    by ascj
    Replies
    10
    Views
    1,217

    Are you saying that I can't modified equipment...

    Are you saying that I can't modified equipment files with 6.0 and dump them into a 4.2 Ivu? Or I can after I get the lastest updates?

    I'm going to pissed if I can't. My rep swore I could modify...
  4. Thread: Carrier Ivu

    by ascj
    Replies
    10
    Views
    1,217

    So I'm back at it, again. I had to change alot...

    So I'm back at it, again.

    I had to change alot of the programming in a 6400. So I need to remap the points for Ivu. So I discussed getting 4.2 software from our rep. He tells me I should get...
  5. Replies
    4
    Views
    185

    Sorry....I should explain myself better. I...

    Sorry....I should explain myself better.

    I know how Bacnet MSV points work. My issue is with existing programming that I have. Most of my existing programming was done with Lon Spyders. Bacnet...
  6. Replies
    4
    Views
    185

    Honeywell Bacnet Spyder

    How do you pull in enumerated points in from Bacnet Spyder? I see that the Venom apps have them, but I can't seem to figure out how to do it.

    The Bacnet object is an AV and the only options I get...
  7. May I add if you are writing to the Discharge Air...

    May I add if you are writing to the Discharge Air Cooling Setpoint and have the machine setup to reset DA locally..........it will add the reset to what ever setpoint you are writing. If you are...
  8. Replies
    5
    Views
    347

    What's the problem?

    What's the problem?
  9. Thread: Niagara Facets

    by ascj
    Replies
    1
    Views
    241

    Niagara Facets

    I am doing a job now, where we are developing a user interface to lay on top of existing digester systems. The PLC's have a option to go to metric or imperial. I'm trying to figure out a way to...
  10. Thread: Rover Cables

    by ascj
    Replies
    4
    Views
    256

    Yes it is......Rover just comes with a fancy RJ12...

    Yes it is......Rover just comes with a fancy RJ12 to Terminal block wire. But you can easily make that yourself.
  11. Thread: Rover Cables

    by ascj
    Replies
    4
    Views
    256

    You are better off just buying the adapters...

    You are better off just buying the adapters elsewhere and making your own cables.

    These are the same exact adapters you would get with Rover.....

    Comm4-...
  12. The way I read it- Slope is your scale. So...

    The way I read it-

    Slope is your scale. So you need to figure out what every 4mA needs to read. Your sensor is 30-95 degrees at 4-20mA. (95-30)/4 So your slope should be 16.25

    Intercept is...
  13. Replies
    17
    Views
    595

    Yes....it's called the enhanced driver. It was...

    Yes....it's called the enhanced driver. It was suppose to be available at some point(don't see it ever happening).......but only Carrier has access to it. Carrier also has a Ivu Integrator. It...
  14. Replies
    17
    Views
    595

    If you can get an enhanced driver from...

    If you can get an enhanced driver from Carrier......let me know. I myself have hit nothing but a steel wall.

    What's the original Ivu? Is it a plus or standard? If it's a plus with a Ivu...
  15. Thread: Ax Supervisor ?

    by ascj
    Replies
    7
    Views
    344

    You only have one platform....so only one port. ...

    You only have one platform....so only one port. If you want to run two separate web services, then yes you would have to change the webservice ports. But the sites we setup run just one web service...
  16. Replies
    17
    Views
    595

    Well you found out the big draw back of the...

    Well you found out the big draw back of the Tridium CCN driver. Maintenance and Configuration point table are not discoverable and they don't allow for manual point adding. Even though the original...
  17. Replies
    16
    Views
    645

    Whats a VUV? Variable Unit Ventilator?

    Whats a VUV? Variable Unit Ventilator?
  18. Replies
    17
    Views
    595

    How are you integrating the system? Jace with...

    How are you integrating the system? Jace with CCN driver, directly on the CCN network.........or you utilizing a Ivu Link and bringing in points via BacNet?
  19. Thread: Ax Supervisor ?

    by ascj
    Replies
    7
    Views
    344

    Why are you running two stations.......one with...

    Why are you running two stations.......one with trending/reports and one with alarms?

    You can run as many stations as you want........they just need different ports setup for each fox service.
    ...
  20. Thread: New laptop

    by ascj
    Replies
    9
    Views
    519

    I'll give you a call on Wednesday. I have to...

    I'll give you a call on Wednesday. I have to hang with you boy Mr Snyder, tomorrow.
  21. The CCN driver is licensed to a Jace and can only...

    The CCN driver is licensed to a Jace and can only be used on one port.
  22. Thread: New laptop

    by ascj
    Replies
    9
    Views
    519

    You can still get any Dell Laptop with Windows 7...

    You can still get any Dell Laptop with Windows 7 Pro. But Windows Virtual XP mode is garbage. The best thing I ever did, is buy VMWare.

    You going to Broudy for your AX Cert? Let me know if you...
  23. Thread: Modbus Help

    by ascj
    Replies
    11
    Views
    491

    Thanks.......I think I'm just going to bring them...

    Thanks.......I think I'm just going to bring them in as 4 separate proxy points. It seems the easiest way to handle them.

    I was worried about resources, since this was suppose to go on a...
  24. In what way?

    In what way?
  25. Yes it's done all the time. Just make sure you...

    Yes it's done all the time. Just make sure you set the stops on the Belimo to stall the actuator. The Envirotecs are only a 45 degree damper stroke.