    Classroom unit ventilators

    Does anyone have any recommendations regarding unit ventilators? We now have Trane which requires the Rover software to troubleshoot. We would like to get away from anything proprietary. The school...
  2. Replies
    3
    Views
    420

    steam boiler sizing

    I have 400 sq ft of radiation determined by measuring up the steam radiators. I want to install a peerless oil fired steam boiler that puts out 480 sq ft. Is there a rule as to oversizing or...
  3. Thread: Pricing

    by chillwater
    Replies
    5
    Views
    557

    Thanks beenthere. I will apply .

    Thanks beenthere. I will apply .
  4. Thread: Pricing

    by chillwater
    Replies
    5
    Views
    557

    Thanks. Can I assume pricing can be discussed...

    Thanks. Can I assume pricing can be discussed there?
  5. Thread: Pricing

    by chillwater
    Replies
    5
    Views
    557

    Pricing

    Hello . I am a contractor in the northeast. I would like to know if I may ask about pricing. Specifically for residential equipment. Is this allowed on this site and if so what forum?
  6. Thread: Permits

    by chillwater
    Replies
    2
    Views
    374

    LOL

    LOL
  7. Thread: Permits

    by chillwater
    Replies
    2
    Views
    374

    Permits

    Does an HVAC contractor in New Jersey need a permit to replace a Heat Pump condensing unit?
  8. Thanks ControlsDude15, I'll check the site out.

    Thanks ControlsDude15, I'll check the site out.
  9. Fault code for325 Microtech controller in HermanNelson AVS classroom unit ventilator

    This unit is from 2001 and is a face by-pass setup with a hot water coil and DX cooling which is not conected. The unit is not heating the classroom. I found the system in Bypass and the status light...
  10. Replies
    1
    Views
    812

    Lennox/Dunkirk GWB9 or Q90-100

    This boiler is an earlier model installed in 2001. The boiler is going off at 120 degrees F and is always short cycling .
    I checked gas pressure and it was 2.5" wc. I checked all safetys and high...
  11. Thanks Again. Just got off the phone from Carrier...

    Thanks Again. Just got off the phone from Carrier and it looks like it could be a sale, especially when the customer wanted the Acadia system originally when we pulled the plug due to the obvious.
  12. That being advised, what is the number of...

    That being advised, what is the number of control wires from the thermostat to the controller.
  13. Thank You, isuredo.

    Thank You, isuredo.
  14. advice on the best & most efficient air to air heat pump

    Good morning. I am looking for any advice that would help me give my customer the best and most efficient air to air heat pump. The area to be conditioned calls for 2-2.5 tons of cooling. I have...
  15. Replies
    0
    Views
    437

    Burnham ES2-4NI-T toubleshooting

    Any suggestions on troubleshooting a no start complaint. Boiler has power to. No activity on display board. Customer had a power surge hit his home when the transformer on the pole blew up when Sandy...
  16. Replies
    14
    Views
    1,694

    Birmingham, Its a great way to heat a home. You...

    Birmingham,
    Its a great way to heat a home. You feel warmer with lower thermostat settings because the heat is from the floor. The heat pump is used in the spring and the fall when it is more...
  17. Replies
    14
    Views
    1,694

    Thanks for all the good advice. I have a meeting...

    Thanks for all the good advice. I have a meeting with the owners tomorrow. Just re-did load calcs for basement zone as they just added 6" framed walls( not on plans) with future insulation. Total...
  18. Replies
    14
    Views
    1,694

    Thanks. I am not a fan of residential zoning...

    Thanks. I am not a fan of residential zoning either which is why I asked the question. I do plan on using a dump with other controls as suggested. I would rather have them switch the basement to...
  19. Replies
    14
    Views
    1,694

    zoning heat pump system

    Is it practical to put a 2 zone system in new construction when one zone will be calling for 2 tons a/c (1st floor) and the other calling for 3/4 ton ac (basement)? The air handler will be located in...
  20. Replies
    2
    Views
    383

    He has already blocked the return of which I...

    He has already blocked the return of which I suggested also. Doing some homework it seems that running the fan once a day fixes the problem. I am guessing that the cooling of the house down will come...
  21. Replies
    2
    Views
    383

    controlling indoor blower on-off times

    Can anyone recomend a thermostat that I can program to cycle the indoor blower on -off for about an hour each day. I have a customer who has condensation problems in his attic flex ducts during the...
  22. Replies
    5
    Views
    899

    Yes, I am talking about warm air furnaces. Thanks...

    Yes, I am talking about warm air furnaces. Thanks for your response and good advice.
  23. Replies
    5
    Views
    899

    Concentric vents

    What are the reasons for concentric vent kits for 90 plus furnaces being equipment specific? Other than the size ie; 2" & 3" are they not all manufactured the same?
  24. Replies
    0
    Views
    533

    concentric vent kits

    Can an Amana/Goodman concentric vent kit be used on a Trane condensing gas furnace or other furnace's as long as they are sized correctly? Are they all the same?
  25. Replies
    14
    Views
    1,672

    I thought I did. I'll check again. Just printed...

    I thought I did. I'll check again. Just printed off a copy of your link.
    Thanks again. Good nite
  26. Replies
    14
    Views
    1,672

    Where did you find it and how come I could not...

    Where did you find it and how come I could not find it on the comfort site?
  27. Replies
    14
    Views
    1,672

    Thanks JimJ

    Thanks JimJ
  28. Replies
    14
    Views
    1,672

    4TWR3048B1000A

    4TWR3048B1000A
  29. Replies
    14
    Views
    1,672

    I called today only because I could not find...

    I called today only because I could not find there recomended piping application guide SS-APG006-EN on the comfort site. I have a low confidence level as to the person I spoke to because when he got...
  30. Replies
    14
    Views
    1,672

    Refrigerant pipe sizing

    I am installing a trane 4 ton heat pump. Refrigerant R410a. The pipe run is 67 feet plus 7 -elbows. Included in the 67 feet is the 7 ft vertical change ,the evap being lower than the condenser. ...
  31. Matching a First co a/h to a Rheem heat pump

    First co VHXB-HW series variable speed a/h says no.
    Rheem says yes. First co says it is an issue with there board.
    Rheem says just use B term on stat instead of O.
    Rheem reverses in cooling...
  32. Replies
    2
    Views
    565

    Thank you for your response. First co. says no....

    Thank you for your response.
    First co. says no.
    Rheem says yes.
    Clarification would be appreciated.
  33. Replies
    2
    Views
    565

    Rheem Heat pump + First .co A/H

    I want to purchase a Rheem RPQL-048JE2 heat pump to connect to a First.co A/H 48VHBXB-HW. This will allow for the tax credit. I am told by First .CO that because Rheem reverses in the cooling cycle...
  34. Replies
    6
    Views
    1,596

    Its a 520.

    Its a 520.
  35. Replies
    8
    Views
    1,884

    Thanks for the offer BAS-PRO. Its in Northwest...

    Thanks for the offer BAS-PRO. Its in Northwest N.J. $$$$$$$$$ service call.
    So far it has been charity with the exception for parts. The odd thing about this is they have already had trane + the...
  36. Replies
    6
    Views
    1,596

    Thanks JD. That seems to be the general consensus.

    Thanks JD. That seems to be the general consensus.
  37. Replies
    8
    Views
    1,884

    I canget the software which is Rover - Lon Talk &...

    I canget the software which is Rover - Lon Talk & hardware from trane for a price of course. It is expensive but reasonable as much as software goes for . I would tell you the $$$ but I think that is...
  38. Replies
    8
    Views
    1,884

    Thanks for the advice. I was leaning towards that...

    Thanks for the advice. I was leaning towards that direction. My only ? is what's involved in using the software. Is it a load and use or is training required? Thanks.
  39. Replies
    6
    Views
    1,596

    Checked today with no results. Any other...

    Checked today with no results. Any other thoughts. Thanks
  40. Replies
    8
    Views
    1,884

    Tracer ZN 520

    Working on a trane classroom UV with DX cool And hot water heat.System has wall mounted zone sensor + unit mounted fan switch. The system is not responding to a call for heat. The system will not...
  41. Replies
    6
    Views
    1,596

    Trane classroom unit ventilator problem

    I am troubleshooting a DX cool/ Hot water heat system with a ZN510 Board.
    The service call is no heat. The fan runs continously and will not shut off using the built in timer. I can shut the fan off...
  42. Replies
    3
    Views
    756

    rover

    thanks for the reply. how do i go about getting rover.
  43. Replies
    3
    Views
    756

    Trane unit ventilator

    I am an owner/operated hvac business doing some volunteer work for a small christian school that has the trane VUVC units. I have done ok so far doing minor repairs however I was told software and a...
  44. Replies
    2
    Views
    2,587

    Sizing a Buderus GB142

    This new home calls for a heating load of 65,000 btuh @ 0 degrees F outside ambient. Load calcs done using wrightsoft software. There has been 18000 btuh of radiant staple up installed. The entire...
  45. Thread: Test

    by chillwater
    Replies
    4
    Views
    679

    ans

    test
  46. Thread: Test

    by chillwater
    Replies
    4
    Views
    679

    answer

    test:) :( :rolleyes: :mad: :p :o
  47. Replies
    1
    Views
    593

    Best HVAC system for cape cod home

    I am building a 2300 sq ft home and am considering radiant on the 1st floor with a forced air a/c system + hot water coil . Baseboard on the 2nd floor( only 2 beds +1 bath).Undecided on a/c . Any...