Search:

Type: Posts; User: markwolf

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. If everything was the same size & configuration...

    If everything was the same size & configuration an install can go amazingly fast.
  2. good advice! evap is junk & where is the gas...

    good advice! evap is junk & where is the gas going?likely the cond is leaking.
  3. good advice! evap is junk & where is the gas...

    good advice! evap is junk & where is the gas going?likely the cond is leaking.
  4. Replies
    10
    Views
    383

    Ask the contractor how much more he charges for a...

    Ask the contractor how much more he charges for a new lineset.Only he can give you his prices.
  5. Replies
    10
    Views
    383

    In some areas a fused disconnect is required.The...

    In some areas a fused disconnect is required.The circuit breaker is sized for the branch & fused down to protect the unit.Changing the breaker would be a waste of time & money if this is the case.
  6. File a complaint with the public housing...

    File a complaint with the public housing authority.
  7. Replies
    28
    Views
    945

    Anytime a system is open the drier should be...

    Anytime a system is open the drier should be replaced.Arguing otherwise with the guy that signs your check is not very smart.imo
  8. Leave the transformer in place.It is not uncommon...

    Leave the transformer in place.It is not uncommon on large facilities to have voltage drops on peak hours,the buck n boost is there to protect from brown outs.I know of one mall with one on every...
  9. Replies
    12
    Views
    300

    arzel is top of the line stuff imo.

    arzel is top of the line stuff imo.
  10. Replies
    12
    Views
    494

    A little teflon tape on the threads lets it get a...

    A little teflon tape on the threads lets it get a bit tighter.oil the seal on the cap & tighten it down.The cap is made to seal.1/12 of a turn after tight should be good.I have seen guys goober them...
  11. Replies
    10
    Views
    259

    If I remember right there are a few short screws...

    If I remember right there are a few short screws here n there.put them back where they came out & it should be easy.
  12. hmmm insane people don't belong in the service.I...

    hmmm insane people don't belong in the service.I guess the guy in panama that thought he was back in vietnam or what ever didn't belong there.
    He did his job evidently because the sicko had at least...
  13. I would be proud to let a chick with a d!ck save...

    I would be proud to let a chick with a d!ck save my life!
    Seriously why would anyone care about the sexual orientation of someone as long as they pulled their weight when the stuff hit the fan?
    I...
  14. Replies
    4
    Views
    325

    I think the supplier sold him the stuff to do...

    I think the supplier sold him the stuff to do it.seems they would have told him to leave if they didn't
  15. A bag of towels a shop vac & a steam cleaner like...

    A bag of towels a shop vac & a steam cleaner like a shark or comparable.
    If you use a degreaser chemical better read to make sure it is aluminum safe first.
    had some pretty good luck with no rinse...
  16. Replies
    8
    Views
    369

    5 tons on 7/8? sounds like the supplier is a...

    5 tons on 7/8?
    sounds like the supplier is a goof.
    since when does a supplier have more weight than the manufacturer that paid pile of cash out to have the unit ari tested at their specs?
    1 1/8 x...
  17. It's not hard to be a tool junkie!I have five...

    It's not hard to be a tool junkie!I have five different meters just on my truck.probably six manifold sets another six in the garage etc.
    I think if I looked hard enough I can find the widget that...
  18. Replies
    3
    Views
    212

    why not calibrate with a standard coupler & check...

    why not calibrate with a standard coupler & check it for consistancy on any pipe?
  19. I would think 2" wall armaflex sealed & covered...

    I would think 2" wall armaflex sealed & covered should do it.
  20. Replies
    51
    Views
    2,309

    Best of luck I just turned an app in for a dream...

    Best of luck I just turned an app in for a dream job myself.
  21. Replies
    15
    Views
    605

    My guess on the mold would be extended runtime...

    My guess on the mold would be extended runtime with reduced airflow/dirty filters.
    have fun cleaning them it is a pita.
  22. Replies
    10
    Views
    493

    This is the slow time of year.It took me three...

    This is the slow time of year.It took me three months to get my first apprenticeship.
    Wait till spring warms things up it will change.
    Just keep filling out apps .
  23. Replies
    7
    Views
    389

    oh sorry that one throttles the dampers.That's...

    oh sorry that one throttles the dampers.That's what I mean about referring to the books haha
  24. Replies
    7
    Views
    389

    carrier specs txv for zones never saw one...

    carrier specs txv for zones never saw one without.
    Sorry we deal with so many zone systems I pull the manuals when I work on them.
    Is there a dump damper or barometric bypass installed that could...
  25. Sounds like the tech had no adapter to test the...

    Sounds like the tech had no adapter to test the flame signal for the smart valve & was guessing what was going wrong.
    I would call a heil or tempstar dealer to check it out.
    If it was never cleaned...