  1. hey man how's that store looking so far. Did they...

    hey man how's that store looking so far. Did they tie a water tower to it or just VSR condensers....
  2. Replies
    16
    Views
    738

    I'm thinking this is a product issue and not a...

    I'm thinking this is a product issue and not a Refri problem....i have graphed these cases for over 5 days and its like clock work they don't hit 50* idk
  3. Replies
    16
    Views
    738

    The fans that are in this case are that ECM motor...

    The fans that are in this case are that ECM motor and blade combo they are black i forgot the exact name of it
  4. Replies
    16
    Views
    738

    yes it does and i don't lose any airflow at all....

    yes it does and i don't lose any airflow at all. At first i thought my coil was frosting up right before defrost but that wasn't the case
  5. Replies
    16
    Views
    738

    not that i have seen or smelled

    not that i have seen or smelled
  6. Replies
    16
    Views
    738

    I have thought of that cause out of all the cases...

    I have thought of that cause out of all the cases in this store this is the only line up with the issue. I have called HP and they have assured me i've got the right motor package
  7. Replies
    16
    Views
    738

    there is a staging area in the stock room where...

    there is a staging area in the stock room where the conditions are good as well
  8. Replies
    16
    Views
    738

    Odd Beer Case issue

    Ok i got a 24ft line up of Beer( Hill O5DM Case) the issue that im having is i'm getting some mold on the Beer packages.
    My case setpoint is 36* my rack is 404a +20SST. I've played with 3 defrost a...
  9. Thread: CPC

    by gatorfan9606
    Replies
    11
    Views
    985

    [QUOTE=Pounds;15435531]Does anyone know the part#...

    [QUOTE=Pounds;15435531]Does anyone know the part# for the ribbon cable that connects the PIB Board to the main processor board?. Can't find # anywhere online.[/QUOTh
    That's for an E2 is that what...
  10. Thread: CPC

    by gatorfan9606
    Replies
    11
    Views
    985

    i use the cpc-637-4801 noise abatement kit

    i use the cpc-637-4801 noise abatement kit
  11. Replies
    98
    Views
    7,836

    (R438a) is been used alot in the A/C conversions...

    (R438a) is been used alot in the A/C conversions down here in the big supermarket chains and 407a for racks it was R422d but that faded quick..
  12. Replies
    5
    Views
    465

    agree with jp its an excellent 3 or 5 day class....

    agree with jp its an excellent 3 or 5 day class. Copeland is always updating there equipment and components
  13. Replies
    16
    Views
    1,588

    Agree 100% there 3ways are not very srvc-able

    Agree 100% there 3ways are not very srvc-able
  14. Replies
    11
    Views
    1,100

    i have found the wires going to the 3 way valve...

    i have found the wires going to the 3 way valve or DDR valve with a short at the connector i have never had a bad control breaker your going to have to chase the common wire and see if you can find...
  15. Replies
    0
    Views
    431

    CX400 & FSD

    i have a cx that is not finding the fsd panel i have a cat 5. cable going to it now should the i.p on the fsd be minus 1 of the i.p prefix or the same as the i.p at the cx
  16. Thread: 404a/507

    by gatorfan9606
    Replies
    10
    Views
    751

    maybe 407-c??

    maybe 407-c??
  17. Thread: 404a/507

    by gatorfan9606
    Replies
    10
    Views
    751

    never heard of 507c i have heard of 507 and i...

    never heard of 507c i have heard of 507 and i have never changed gas on a ice machine if its been running on 507 why change???
  18. i have an 88ao board that does what you have we...

    i have an 88ao board that does what you have we have 2 cond set up's on the E2 one controls the ec motor with 1set of pressures the 2nd controls the standard motors with another pressure control...
  19. Replies
    10
    Views
    1,245

    so we're are using temp control instead of...

    so we're are using temp control instead of pressure?under the set up or are we using differential
  20. Replies
    29
    Views
    2,209

    thx for explaining it might have to try this

    thx for explaining it might have to try this
  21. Replies
    29
    Views
    2,209

    just a question phase.why would you want other...

    just a question phase.why would you want other circuits to run the float while the lead circuit is in defrost?when it comes out of defrost the float would be to high and now the that circuit is going...
  22. Replies
    29
    Views
    2,209

    if i understand you correctly if i set my suction...

    if i understand you correctly if i set my suction stpt to 14# and my min on the float to 16# and my delay every 5mins at 10mins it will start to go up to 16# i think im over thinking this lol
  23. Replies
    29
    Views
    2,209

    i agree with you 100% the min. should match the...

    i agree with you 100% the min. should match the suction setpoint for some reason i don't think the float app will not work if it doesn't match i could be wrong thats why i asked anytime i set one up...
  24. Replies
    11
    Views
    1,137

    we've been dealing with this problem for a very...

    we've been dealing with this problem for a very long time at one point T thought we were full of $*** now they just sent us 200 of those gaskets not fun replacing them either you almost need a troll...
  25. Replies
    29
    Views
    2,209

    ok i got a question that its been explain to me...

    ok i got a question that its been explain to me 10 diff ways:when setting up a float app.on an E2 or RMCC and your suction set point is say 14# now under float set up under min-max do you start your...