  1. When using Static Pressure as the target...

    When using Static Pressure as the target measurement for desired volume the formula becomes SP2 = SP1 x (CFM2/CFM1) squared
  2. A calibrated capture hood is the easiest and most...

    A calibrated capture hood is the easiest and most convienient method of measurement since you don't need to use a "correction factor" for the Ak (free area factor) which would be required using a...
  3. Replies
    10
    Views
    4,658

    In keeping with the general "rule of thumb" that...

    In keeping with the general "rule of thumb" that 400 - 500 cfm expected per ton of cooling then, 430 cfm return would be low, or about 21% of the estimated 2,000 total cfm for a 5 ton unit (unless...
  4. Replies
    10
    Views
    4,658

    Depends on if the unit is single fan or dual fan....

    Depends on if the unit is single fan or dual fan. (supply fan only or supply and return fans)
    Also, if dual fan, what minimum OA and minimum EA design is at full mechanical cooling.
    If single fan,...
  5. Replies
    15
    Views
    7,310

    For TRANE VAV's, the K-Factors is actually the...

    For TRANE VAV's, the K-Factors is actually the volume in CFM that the box should deliver at 1.00 inch of pressure drop.
    How-ever, these are based on ideal installed conditions which are not always...
  6. Replies
    10
    Views
    1,567

    say it isn't so.....

    I had a rank odor coming through my house duct system.
    Traced it out and found a dead. half-rotten rat in the main duct.
    The smell would knock a dog off a gut-wagon.
  7. Replies
    45
    Views
    1,624

    I play guitar as a hobby...

    TAB = Testing, Adjusting and Balancing
    (never thought about TAB = music tabulation) good one tho!
  8. Replies
    45
    Views
    1,624

    Check this one out...awesome!!

    Check out this one and reply what cha think.

    http://www.youtube.com/watch?v=O9mEKMz2Pvo
  9. Replies
    22
    Views
    1,405

    you are right...for the most part

    For the most part, adding restriction to the available air flow will also lower the current draw. This also depends on what TYPE of fan wheel you have.
    If "Vaneaxial fans" are used, adding...
  10. Thread: water flow

    by tab-tech
    Replies
    15
    Views
    1,112

    CV value of valves

    CV values of valves are also typically based on straight water without any additives such as glycol or rust inhibitors, etc.
    If additives are used then there is a correction factor required.
    If you...
  11. Thread: water flow

    by tab-tech
    Replies
    15
    Views
    1,112

    CV value of valves

    The CV value of valves are typically the volume of water in (GPM) the valve will provide at a 1.0 psi drop at full open.
  12. Thread: water flow

    by tab-tech
    Replies
    15
    Views
    1,112

    Try burping the system.

    Have you checked the possibility of an air bound coil?
    Air becoming trapped at coil high points can cause water flow to be sluggish.
    Try venting the system at high points until you burp it.
  13. Replies
    2
    Views
    477

    Considered ceiling paddle fans....

    You could put electric strip heat in the ducts but you would have to add in the electrical cost of running the fan. They work like toasters.
    Electric heat is 100% efficient. Only trouble with that...
  14. Thread: Infra Red

    by tab-tech
    Replies
    20
    Views
    2,005

    I/R good for Delta T measurement

    I/R readings are best I find for verifying temperature differentials.
    Even if the actual temperatures tested are "off"...they will be "off" by the same amount of error giving you a good indication...
  15. Replies
    97
    Views
    5,794

    Thats what I'd call.....

    ...dryer than a Popcorn Fart.
  16. Replies
    97
    Views
    5,794

    I live in Maine where economizer cooling...

    ... is the cats meow. I've seen conditions in early mornings where OSA temps are 55 - 60 degrees with RH levels at 90% or higher. (dense fog from dew lifting off the ground and surface water...
  17. Replies
    15
    Views
    7,310

    Sometimes K factors are....

    ....the amount of CFM a box will deliver at 1 inch of differentialpressure.
  18. Replies
    18
    Views
    1,190

    TOUCHE'..........

  19. Replies
    8
    Views
    633

    Ask an Afghanny...

    Iraqi freedom will not give way to the tyranny that once ruled, for they have now tasted the sweetness of freedom.
    Its like their country has just put on a new pair of shoes.... they are gonna have...
  20. Replies
    12
    Views
    1,482

    You are still basing your mixture on a percent of gallons in the system.....

    .....you are just simply using temperature/color shade as the medium of determination.
  21. Replies
    1,030
    Views
    30,037

    Get a grip believers.....

    ScrogDog doesn't care what anyone else thinks...he's just trying to beat the 9mm thread.
    Winds up... he's beating a dead horse.
    As Bootlen stated way back at the beginning of this topic...

    ...
  22. Since all fans (and pumps for that matter).....

    ....work on a differential pressure based curve...I'm thinking that outside air intake ducting will typically offer less resistence then it's return air ducting. There-fore, to move the same amount...
  23. Replies
    12
    Views
    1,482

    I recall reading somewhere.....

    ....that capacity loss will always be found when using glycol in a system.
    The loss when the mixture is above 30 - 40 % is greatly increased.
    Good ol' plain water (no additives like floride,...
  24. Replies
    17
    Views
    886

    Ahhh for the good 'ol days.....

    ....when a persons' word was as good as gold.
    Sorry to hear about you and your Dad...the stuff in between us would bother me more than the incident itself.
    Sometimes we must learn not only by our...
  25. Replies
    17
    Views
    886

    A new WalMart just opened up here.....

    ....and they have several "self-checkout lanes for your convenience" much the same as described by Bootlen / Blockbuster senerio.

    I think "convenience' here means at the collection of payment...
Results 1 to 25 of 114
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event