  1. Thread: JCI

    by just_opinion
    Replies
    8
    Views
    830

    JCI

    We have a customer, who has NC350 with OSW and DX9100, UNT, etc.. This site is 15 or so years old.
    I my question is if the OSW dies, do we have to change all UNT, DX9100, etc.. out?
  2. Replies
    5
    Views
    366

    Yes, of course Don't measure, don't care....

    Yes, of course



    Don't measure, don't care. These boxes temperatures NEVER rise to -37 degrees in the past 2 years that I work on them. Stay around -40 to -41
  3. Replies
    5
    Views
    366

    2 stage Extended Low Temp

    I pulled out 4 set of these to install Scroll compressor and evaporators with electric defrost. Don't ask me why. I am just a worker and not the owner. I work on these since these electronic stuffs...
  4. Replies
    3
    Views
    443

    EXV and more

    I posted it in the Pro thinking there is only 1 Refrigeration Site. But I want to post it here for more people to see. Sorry Administrator.

    Let me know if you are interest in purchasing these....
  5. Old YT york chiller with e-link board.

    Is there a way to reconfigure the chiller processor board so that it will not follow the E-link ENABLE variable? That way we can use conventional relay to S/S the chiller via point 1,7,8.
    The e-link...
  6. Replies
    3
    Views
    291

    Thanks

    Thanks
  7. Replies
    3
    Views
    291

    DX 9100 version 2.4

    I direct-connect to this controller and uploaded all points. My question is "I cannot override the analog input value such as Outdoor Temp so I can see if my logic is working".
    It stated "override...
  8. Replies
    5
    Views
    467

    This customer has multiple site that have CCN. I...

    This customer has multiple site that have CCN. I remember I connected to one site. But some how some way I managed to see and to change some of the logics. Example: I managed to change the...
  9. Replies
    5
    Views
    467

    Carrier ccn

    I got several controller 6400-Rev 4 that I cannot pull the program logics using network service tool V 2.2. I can pull all data and setpoints and I can change setpoint. Also do force On and sensor...
  10. Replies
    2
    Views
    417

    Try it next week. Thanks

    Try it next week. Thanks
  11. Replies
    2
    Views
    417

    direct connect to N30

    I have seen several threads regarding to direct connecting the laptop to the JCI N30 via VT100 or hyper terminal. But...
    I have a customer with Metassys. Each time they have control issue, I brought...
  12. Thanks Kenneth

    Thanks Kenneth
  13. We has a customer with this ccn network, which I...

    We has a customer with this ccn network, which I rarely deal with. I just want a literature to refresh me. I have issue with this site that our tech was. This site has only 2 IO controllers. But from...
  14. Carrier network service tool V user's manual.

    Does anyone have it in the pdf.file ? I google the web and could not find any where.
    Found the version IV though, which is running in the DOS

    Thanks
  15. I do appriciate you all. I got the patch for my...

    I do appriciate you all. I got the patch for my older version 8.04b. And it works.
    I rarely use CCT and JCI. Except couple job sites, where the owners despise JCI, who is ...
    Thanks
  16. Thanks for the info memo. Now, where can I get...

    Thanks for the info memo.
    Now, where can I get that patch files? Does anyone has that HVACpro804patch.zip
  17. JCI AP-Vma14200-0 controller upload issues via HVAC Pro version 8.04

    I already posted it in the Pro forum. But, I want to post it in the open forum, where more people encounter this issue.

    Come across this school having these. I use laptop with HVACpro 8.04 and USB...
  18. Replies
    9
    Views
    1,447

    After 22 years living with that goodman...

    After 22 years living with that goodman equipment, how was the comfort level in your house?

    If the answer is "comfortable and no complaint" then go with that size. After all, experience always...
  19. Manufacture (I dont think) give SEER on the low...

    Manufacture (I dont think) give SEER on the low stage cooling. But according to the unit performance data, it get a lot more bang for a buck.
    It makes sense if we think about it - much larger...
  20. I forgot to mention that one of those controllers...

    I forgot to mention that one of those controllers is controlling the chilled water pump VFD. This is of course the Johnson Control VFD too. And it is "an upgraded". The old honeywell system did not...
  21. Harmony zone from Lennox is great system. But...

    Harmony zone from Lennox is great system.
    But
    1) if you ONLY do 2 zones in your house. I go with 2 stages, which csn give you the comfort for less $$
    2) That saleman should do MJ and offers you a...
  22. Replies
    1
    Views
    566

    2 carrier package units ccn lead/lag

    Wonder in the ccn, if we can tie them together and do lead/lag?

    I knowthe chillers have the lead/lag logic in their ccn.

    Wonder if it is in package units.

    Thanks
  23. Replies
    3
    Views
    1,414

    Yellow book. Oh! That't right. I forgot that You...

    Yellow book.
    Oh! That't right. I forgot that You said your company dont want to spend the money to get the problem fix.
  24. Poll: Can't have GAS FURNACE and cooling run at the...

    Can't have GAS FURNACE and cooling run at the same time for dehumidification.

    When a tech tell you "I have 30 years experience in HVAC" and does this stuff.

    Just walk away.

    What is 30 x 0 =...
  25. When you say "high humidity" - how high? Please...

    When you say "high humidity" - how high? Please provide dry buld and relative humidity %.

    When you say contractor give you option for unit sizes - Did they do the load calculation. Cuz without it,...
  26. Replies
    3
    Views
    1,760

    That's a thing of beauty

    You can't touch this!
  27. Replies
    38
    Views
    4,730

    I find it hard to believe that Aaon unit does not...

    I find it hard to believe that Aaon unit does not have any control module in it. You meant this unit has nothing but bare contractor and safety switches. I've seen my share of this unit.

    And if it...
  28. Replies
    20
    Views
    2,386

    When do zoning, which is best in your case, go...

    When do zoning, which is best in your case, go with variable speed inside and outside with no bypass damper.
    One more note: earth grounding on all your electrical components is the MUST. They are...
  29. Jci took out the old honeywell control. That is...

    Jci took out the old honeywell control. That is an old hw box, old hw wires. The only new wires they ran was the comm wires. The old hw comm wires are not shielded.
  30. JCI team in Beaumont TX with another "world class service"

    8 months old at a nice Hamshire Fannett High School Texas.

    JCI world class of service.
  31. Replies
    7
    Views
    920

    They replace the existing Honeywell control for...

    They replace the existing Honeywell control for this JCI for energy saving bond.

    JCI team in Beaumont TX branch. Picture worth one word.
    I spent 45 minutes on that site and speechless.
    There is...
  32. Replies
    7
    Views
    920

    Rev 6.1 This site is only 8 months old. Wish I...

    Rev 6.1
    This site is only 8 months old. Wish I can post the picture showing the workmanship from world class JCI branch in Beaumont TX.
  33. Replies
    7
    Views
    920

    How do I find if the site is set as ADMIN rights?

    How do I find if the site is set as ADMIN rights?
  34. Replies
    7
    Views
    920

    What about schedule and setpoints from this front...

    What about schedule and setpoints from this front end to the Fx? Don't I need SCT to program them?
  35. Replies
    7
    Views
    920

    Fx PCG marrying with Metassys

    I am not too familiar with metassys. Worked with Fx Explorer on couple jobs few years back. Bottom line is I am rusty and novice.
    We are to in stall 2 Carrier package units to this site that has...
  36. Replies
    12
    Views
    2,266

    Your problem cannot be changed easily via PGD...

    Your problem cannot be changed easily via PGD interface. Typically, the setpoint is assigned as permanent memory type of variable. In your case, the programmer himself tried to be cute and upload all...
  37. Just be very careful when you do zoning....

    Just be very careful when you do zoning. Especially with the less-technological package unit, which only have fixed metering device.

    NOT every case is the same. NOT every air condition is the...
  38. No, it cannot be done.

    No, it cannot be done.
  39. Replies
    3
    Views
    885

    Have you changed the thermostat

    Have you changed the thermostat
  40. Replies
    40
    Views
    4,757

    Jesus was perfect too (according to who...

    Jesus was perfect too (according to who believes). But he got criticized all the time. So don't ask. Enjoy it if you think it is best for you.
  41. Od temp has nothing to do with your issue....

    Od temp has nothing to do with your issue. Service call
  42. Replies
    15
    Views
    2,449

    Must use OEM motor. Don't ask me why. Otherwise,...

    Must use OEM motor. Don't ask me why. Otherwise, you will keep replacing it yearly.
  43. That is a 5 tons blower. It is capable of moving...

    That is a 5 tons blower. It is capable of moving more than 2000 cfm. Make sure you ask the contractor to configure it to run less than 1400 cfm in your case (I like 1250 max on your case even though...
  44. By the way, according to Lennox, use approach...

    By the way, according to Lennox, use approach when ambient is warm above 65 degrees; use sub cool during cool weather belie 65 degrees AND also artificially raise the head pressure above 105...
  45. Replies
    20
    Views
    2,661

    I thought NO DIY site

    I thought NO DIY site
  46. You are correct. Today Lennox systems, you will...

    You are correct. Today Lennox systems, you will see that they don't have much of an subcool. Sometimes, it will surprise you.
    But, think about it a little bit. These system run at lower saturated...
  47. You don't need to have llsv on your setup. In...

    You don't need to have llsv on your setup. In facts, it is not good to gave them since it create more issues than help.

    Run the system at lower cfm than 400 since you bring in OSA.

    Try not yo...
  48. Replies
    9
    Views
    899

    If you open the wall up, have same contractor out...

    If you open the wall up, have same contractor out to fix the kink cause it is not good to have it.
    $$$ is between you and your contractor.
  49. With my experience dealing with these trane...

    With my experience dealing with these trane climatuff, you MUST use trane start components. I don't know why but other start kit won't work well with it.
    2nd run your system in a/c mode normally for...
  50. Replies
    8
    Views
    874

    90% of the time, it is the duct works in the...

    90% of the time, it is the duct works in the attic not properly sealed. Especially, when it is 130 degrees up there. I am sure the installers want to get the heck out of there QUICK.