    From the looks of it a bypass version is what I...

    From the looks of it a bypass version is what I would need. It would mount on the return duct and then the bypass would feed into the supply through a 6 inch duct.
  2. Replies
    2
    Views
    815

    My house is very dry and I would like to have a...

    My house is very dry and I would like to have a whole house humidifier installed but there is no place to put a unit on the supply side of the duct work due to limited space. I have read on this...
  3. Replies
    13
    Views
    2,409

    Well just got down to 32 degrees with the balance...

    Well just got down to 32 degrees with the balance point set at 30 and both the HP and the furnace kicked on


    170 set to 7 2 heat/1 cool heat pump - ok
    200 set to 1 fossile fuel is back up - ok...
  4. Replies
    13
    Views
    2,409

    It is set for the 10 minute delay.

    It is set for the 10 minute delay.
  5. Replies
    13
    Views
    2,409

    The outdoor sensor is wired separately from the...

    The outdoor sensor is wired separately from the thermostat to the outside of the house. The 8320 has all the setting for a fossil fuel setup.

    No plenum sensor just the outside temp sensor.

    I...
  6. Replies
    13
    Views
    2,409

    it will run 8 to 12 minutes and then the 90...

    it will run 8 to 12 minutes and then the 90 second extended fan

    My Balance point is set to 30

    for instance this morning the HP came on with out side temp 34 degrees ran fine by itself - ok
    ...
  7. Replies
    13
    Views
    2,409

    they installed the VP 8000 TH8320U1008 will...

    they installed the VP 8000 TH8320U1008 will handle 3 heat and 2 cool and the outdoor temp sensor is installed.

    not sure about the first two questions. Its just a heat pump and furnace set up. I...
  8. Replies
    13
    Views
    2,409

    I have a duel fuel set up which has been working...

    I have a duel fuel set up which has been working fine. All of a sudden yesterday the lockout doesn’t work and both the heat pump and the furnace are firing at the same time. The thermostat...
  9. Thread: CFM Question

    by wango
    Replies
    1
    Views
    651

    I have a 3 ton heat pump and I see many postings...

    I have a 3 ton heat pump and I see many postings recomending setting the system to 400 cfm a ton. I have a duel fuel set up and the furnace heating cfm has a high fire of 1300 cfm and a low fire of...
  10. Replies
    5
    Views
    805

    I have it all set up but it is acting real...

    I have it all set up but it is acting real strange. Its been working fine all week with the HP but it wasn't until last night that the temp went below the Balance point that the problem occurred....
  11. Replies
    5
    Views
    805

    When initially installed and tested the HP would...

    When initially installed and tested the HP would fire on Test 3 # 1 – stage 1 heat on and the Furnace would fire on Test 4 # 1 – emergency heat on

    Now when I run the system test it is firing on...
  12. Replies
    5
    Views
    805

    I have a duel fuel set up and last night it got...

    I have a duel fuel set up and last night it got below the balance point of 35 degrees and kicked on the gas. I also noticed that the heat pump was also kicking on at the same time. (I've switched to...
  13. Replies
    3
    Views
    683

    My house is 2 floors with the furnace in the...

    My house is 2 floors with the furnace in the basement and the return going straight up to the top floor. In the basement as it goes up through the ceiling above the return is formed around 3 cross...
  14. Replies
    7
    Views
    977

    Thanks for all the good info - I think i will see...

    Thanks for all the good info - I think i will see how the Automatic Heat Staging Jumper setting works before i go with a differant thermostat.
  15. Replies
    7
    Views
    977

    so the setup should be based on 2 heat 1 cool. ...

    so the setup should be based on 2 heat 1 cool. And on the unit the Automatic Heat Staging Jumper must be set - this will set the first stage heat for either 5 or 10 minutes before it switches to the...
  16. Replies
    7
    Views
    977

    Need a little help here with my Vision-Pro setup?...

    Need a little help here with my Vision-Pro setup? I have a 95 fue two stage variable speed furnace with a heat pump. The Vision Pro is the 3 heat 2 cool version and the outside temp probe has...
  17. So if I have a HP with a two stage furnace with a...

    So if I have a HP with a two stage furnace with a VS motor I would be stuck with the HP and firststage heat only.

    The VP model I have has 3heat and 2 cool.

    Is it the VP that controls the 1st...
  18. Replies
    18
    Views
    5,596

    I had a duel fuel system put in my house over the...

    I had a duel fuel system put in my house over the summer reusing my HP and putting in a furnace. My installer is coming back at the end of the month to fire up the furnace. He didn’t want to do it...
  19. Replies
    8
    Views
    815

    the fireplace has doors on it with an outside...

    the fireplace has doors on it with an outside fresh air intake which I would think would reduce that from happening. However I guess the concern would be the possibility of drawing smoke and carbon...
  20. Replies
    8
    Views
    815

    My home is three stories with the furnace in the...

    My home is three stories with the furnace in the basement and a return on the 1st and 2nd level. I have a fireplace on the 1st floor that I love to use in the winter but it is in the family room ...
  21. Thread: Glass Doors

    by wango
    Replies
    2
    Views
    1,166

    I have a wood burning fireplace insert with glass...

    I have a wood burning fireplace insert with glass doors and was told i can not keep the glass doors closed when I have a fire going. Something about shattering the glass doors. Any truth to that?
  22. Replies
    2
    Views
    704

    In theory this looks good but does anyone have...

    In theory this looks good but does anyone have any practical experience with it? I have just replaced a dying 14 year old system in my house however my upstairs 4 bedrooms are still warm. 3 of...
  23. Replies
    14
    Views
    1,940

    I need to have the installer back to correct it...

    I need to have the installer back to correct it then. Also I need to find where I can get the outdoor sensor since it didn't come with the Thermostat.
  24. Replies
    14
    Views
    1,940

    I was told on this board that using a Honeywell...

    I was told on this board that using a Honeywell TH8000 series i would not need the control board. That it would handle the heating changes.
  25. Replies
    14
    Views
    1,940

    I just had a new furnace and air handler put in. ...

    I just had a new furnace and air handler put in. The furnace is a Armstrong Air 95V 80000 btu (two stage heat) and I have a 3 ton heatpump. The thermostat can handle 3 heat and 2 cool I am using the...