    And 1570 for cooling.

    And 1570 for cooling.
  2. A bit too much DIY.. Thread closed.

    A bit too much DIY..

    Thread closed.
  3. Replies
    16
    Views
    503

    Which adds up to over 7,290 CFM total. Your...

    Which adds up to over 7,290 CFM total. Your blower is only a 4 ton(1600CFM). So you have the anemometer set up incorrectly. How did you determine the AK/free area of your registers.
  4. Replies
    20
    Views
    398

    Which could be because of a dirty coil, Defective...

    Which could be because of a dirty coil, Defective VS blower motor, or control board. Or some other obstruction to air flow.
  5. Replies
    4
    Views
    174

    1 of the old round ones. 2 tons.

    1 of the old round ones. 2 tons.
  6. Replies
    12
    Views
    361

    No, it only tells you the capacitor's uF under...

    No, it only tells you the capacitor's uF under load. Not what size capacitor to use.
  7. Replies
    16
    Views
    503

    I doubt you had any supply register blowing 850...

    I doubt you had any supply register blowing 850 CFM, let alone over that. Specially considering your furnace's blower is a 4 ton blower(1600CFM). Sounds like you're seeing FPM, and interpreting it as...
  8. They don't make a 17" round duct.

    They don't make a 17" round duct.
  9. Replies
    7
    Views
    142

    How hot is it outside when its takes 4 to 5 hours...

    How hot is it outside when its takes 4 to 5 hours to cool down 5 degrees.
  10. What size is the large flex duct from the air...

    What size is the large flex duct from the air handle to the mix box?
  11. Replies
    10
    Views
    277

    Actually, the single return on the east side, is...

    Actually, the single return on the east side, is probably a bit under sized. And that is why you feel or hear it pulling so hard.
  12. Good chance the return is leaking a lot.

    Good chance the return is leaking a lot.
  13. A larger A/C will recover quicker. Ir will also...

    A larger A/C will recover quicker. Ir will also have short cycles after the homes temp is down, and use more electric to maintain temp at night. And it won't save you any money by having it off...
  14. Replies
    10
    Views
    277

    The west side should take longer to recover when...

    The west side should take longer to recover when its still receiving solar heat.
  15. Replies
    5
    Views
    251

    Moved to Tech to Tech. Based on profile info.

    Moved to Tech to Tech. Based on profile info.
  16. The new returns may be leaking unconditioned air...

    The new returns may be leaking unconditioned air in, and when you close the doors they leave even more unconditioned air into the system..
  17. Replies
    35
    Views
    856

    The compressor still drew LRA after installing...

    The compressor still drew LRA after installing the hard start. Just your meter is not quick enough to measure it.

    The compressor draws LRA everytime it starts.
  18. Replies
    35
    Views
    856

    Thats how we did it before digital meters came...

    Thats how we did it before digital meters came out.
  19. Replies
    3
    Views
    129

    Need to connect it to the hot water line at the...

    Need to connect it to the hot water line at the water heater for it to do anything.
  20. You have to look at the micro climate tables for...

    You have to look at the micro climate tables for many areas. Often way different then the surrounding major area.
  21. Replies
    4
    Views
    243

    Tech may have accidentally set it to more then...

    Tech may have accidentally set it to more then 1200 CFM.

    If your duct work is exposed, they may be able to install balancing dampers.
  22. Replies
    5
    Views
    215

    Yes, its after the metering device.

    Yes, its after the metering device.
  23. Replies
    5
    Views
    215

    Good chance you got a leak in your system. The...

    Good chance you got a leak in your system. The small line isn't a liquid line on a mini.
  24. They are more afraid of you complaining about it...

    They are more afraid of you complaining about it not cooling your house, then you complaining that your electric bill is high.
  25. Well, since 10% of your air was going out the...

    Well, since 10% of your air was going out the evap cooler, and your ducts needed insulated, along with a return needing to be rerouted. You probably didn't need a 4 ton that short cycles(which...
Results 1 to 25 of 500