  1. Replies
    19
    Views
    2,427

    YOUR customers probably call it that because they...

    YOUR customers probably call it that because they are just as misinformed as you are. (No offense)
    I thought you were referring to Carrier also.
  2. Replies
    17
    Views
    2,144

    There are several things that will give you that...

    There are several things that will give you that alarm. High pressure switch, winding stats, and the auxillarys on the compressor circuit breakers. Try tattle tales across the safeties just to verify...
  3. Replies
    3
    Views
    504

    Your information is not making sense. It's 98...

    Your information is not making sense. It's 98 degrees outside, 72 degrees inside. And your units are producing 67 degree air?
    Im guessing that's physically impossible.
  4. Replies
    14
    Views
    3,513

    Are the crankcase heaters working? Does the unit...

    Are the crankcase heaters working?
    Does the unit have l.l. soelnoids?
    Could liquid refrigerant be migrating back through the suction line?
    Those scrolls will trip the breaker if they slug.
  5. Replies
    27
    Views
    1,903

    It has been figured out, replace the fan proving...

    It has been figured out, replace the fan proving switch.
    It is not a Summit issue. It works fine in stand alone mode because the units not switching between occupied/unoccupied.
    It's possible the...
  6. Replies
    3
    Views
    641

    If your replacing just the LLID, that's easy. It...

    If your replacing just the LLID, that's easy. It unscrews from the bottom. I have never replaced the entire float chamber so I am not sure what exactly it entails.
  7. What size Voyager is it? The "delivered VAV...

    What size Voyager is it? The "delivered VAV system" is for the 25 to 50 tons only, not the smaller ones.
  8. Replies
    21
    Views
    17,732

    Your asking the supply house counter guys how to...

    Your asking the supply house counter guys how to install your equipment?
  9. This may be a dumb question but does it require a...

    This may be a dumb question but does it require a full blown freq drive or would a speed control knob suffice. Similar to what you see on FTU boxes. That is technically variable speed.
  10. Replies
    2
    Views
    910

    Just as a test, get a smaller belt, put it on...

    Just as a test, get a smaller belt, put it on just the motor and blower pulleys. That will determine if the noise is coming from the idler pulley.
  11. Replies
    3
    Views
    508

    Two words of advice,"auto local".

    Two words of advice,"auto local".
  12. Replies
    4
    Views
    646

    I use a heat gun to heat the oil and bottle. You...

    I use a heat gun to heat the oil and bottle. You still get the foam but it goes away much quicker.
  13. Replies
    16
    Views
    1,878

    Use the "bird feeder". Use plenty of tubing to...

    Use the "bird feeder". Use plenty of tubing to absorb any erratic readings. These are being used without any problems all over the world. Is there something special about your application?
  14. Replies
    15
    Views
    1,515

    No, it's the only one.

    No, it's the only one.
  15. Replies
    15
    Views
    1,515

    I talked to Clarksville about this. They said the...

    I talked to Clarksville about this. They said the problem is with the plastic insulators on the ring terminals. They actually emit chlorine and corrode the wire. It's not a sizing issue. Once they...
  16. Replies
    4
    Views
    453

    huh?

    huh?
  17. Replies
    11
    Views
    679

    Trane CCP with a touch screen!

    Trane CCP with a touch screen!
  18. Thread: Tower Tech

    by wisecracker
    Replies
    9
    Views
    1,164

    One of our sites has two large Tower Techs. I...

    One of our sites has two large Tower Techs. I dont know anything about them except everytime I go to the site, it looks like it's raining underneath the towers. They loose alot of water. It may be...
  19. Replies
    5
    Views
    790

    Is the unit connected to Summit? The economizer...

    Is the unit connected to Summit? The economizer could be disabled in the Summit editor.
  20. Emerson is putting on a class on scroll...

    Emerson is putting on a class on scroll compressors, I believe in Orlando or Jax. I saw a flyer in Johnstone at the Jax office the other day. You can call them for more info.
  21. Replies
    15
    Views
    2,896

    I thought it was a lip seal problem originally...

    I thought it was a lip seal problem originally but in a conversation that I had with tech support prior to this service call, he said the lip seal failures were "extremely rare". And that alot of...
  22. Replies
    40
    Views
    4,706

    [First thing I do to them is convert them to a...

    [First thing I do to them is convert them to a conventional 24v system with a IFC board and tstat...that being said, my crystal ball says...bad board.

    Not sure what an "IFC" board is but I do...
  23. Replies
    15
    Views
    2,896

    Or visa-versa. Ask me how I know.

    Or visa-versa. Ask me how I know.
  24. Replies
    15
    Views
    2,896

    According to the service bulletin that I have....

    According to the service bulletin that I have. The lip seal failures only occured on the 100 ton compressors.
  25. Replies
    4
    Views
    701

    Try Trane.com

    Try Trane.com