  1. Don't know yet on if Break Even point is 5 years...

    Don't know yet on if Break Even point is 5 years or less. That's the purpose of my efforts to design and implement the measurement & verification system to obtain factual data to show if there is...
  2. Summary of what I've heard / learned so far...

    Summary of what I've heard / learned so far (recommendations):

    1. Install hot gas bypass refrigerant line connection from compressor hot gas output directly to air-cooled condenser input, fully...
  3. The second chiller unit on the roof, and in the...

    The second chiller unit on the roof, and in the pictorial, that does not have any water cooled towers attached to it, has the EvaporCool system on it and functioning. At some point, once the further...
  4. Thanks for the explanations - helpful. The...

    Thanks for the explanations - helpful.

    The water cooling retro tower doesn't have, per se, a bypass for condenser water to circulate in the basin but not fall through the heat exchanger in the...
  5. This is the first time for the retro-cooling...

    This is the first time for the retro-cooling tower manufacturer to install on a chiller.

    The modified chiller is shown running in real time at http://www.welserver.com/WEL0640 . The above graphic...
  6. Correct. Have air cooled chiller. 80 tons. ...

    Correct. Have air cooled chiller. 80 tons. Carrier 30GT series. Nothing fancy.

    Correct. Added WATER cooling tower (one per circuit, inserted between compressor(s) and air-cooled condenser...
  7. Indeed the 30GTs are air cooled. Model is...

    Indeed the 30GTs are air cooled. Model is 30GT-080---61QKA (Flotronic (vs Flotronic II) controlled, across-the-line start, 460V). It does not have any hot gas bypass on either of the 2 circuits. I...
  8. Understanding of Instability of Carrier 30GT Chiller

    I design and implement measurement & verification systems for commercial HVAC systems. I have an M&V and energy monitoring/logging system implemented for Carrier 30GT series 80 ton chillers located...
  9. Replies
    875
    Views
    95,335

    John, thanks for the note. My GSHP HVAC / Energy...

    John, thanks for the note. My GSHP HVAC / Energy monitoring system simply illustrates good GSHP/HVAC principles - thanks for the supportive comment. Many concepts in this long thread are well...
  10. Replies
    875
    Views
    95,335

    I too am watching if / how much my borehole field...

    I too am watching if / how much my borehole field temperature changes long term over a period of years.

    So far I've collected 2 of the 7 years of Entering Water Temperature data that's supposedly...
  11. Replies
    6
    Views
    543

    I was just trying to provide some factual support...

    I was just trying to provide some factual support for what Shophound said, noting that my location is (relatively) the same as his (DFW), and that I have an HVAC monitoring system (...
  12. Replies
    6
    Views
    543

    Here's an example of what Shophound is talking...

    Here's an example of what Shophound is talking about, specific for his DFW location/climate.

    The red line is outside temperature - it got past 102 (F) on July 2nd (red line). Yet outside RH...
  13. Replies
    10
    Views
    1,943

    Here's an illustration of compressor discharge...

    Here's an illustration of compressor discharge temperature as a function of cooling vs. heating mode, for an R410A geothermal system (WaterFurnace Envision 3 ton 2 stage variable speed closed loop...
  14. shophound, with the changed weather pattern the...

    shophound, with the changed weather pattern the last few days, from the almost daily continuous sunshine to cloud cover, I've noticed that there appears to be an additional variable that affects...
  15. Shophound, yep, I agree. Every time the blown-in...

    Shophound, yep, I agree. Every time the blown-in insulation is disturbed, heat flow resistance performance is degraded. In my case I've started using fiberglass batts as additional insulation in...
  16. The RH 1-wire sensors I use are hermetically...

    The RH 1-wire sensors I use are hermetically sealed and thus are ideally suited for installation into the return and supply plenums. Take a look at...
  17. We had it done, a blower door test, for my house,...

    We had it done, a blower door test, for my house, a year or so after the house was built. We failed the test - couldn't get any measureable degree of negative pressure. Too many ceiling open-style...
  18. This image shows a couple of 1-wire technology...

    This image shows a couple of 1-wire technology temp sensors on my 2" HDPE GSHP entering and leaving water loop pipe. It reasonably illustrates sensor hook-up and what is meant by 'linear topology:'...
  19. Shophound, I've been keeping up with your posting...

    Shophound, I've been keeping up with your posting here on how the attic can affect house envelope heating, along with TB's posting on RH. These threads have been helpful reading, and I'm...
  20. Shophound, Another data logging system to...

    Shophound,

    Another data logging system to consider is this one:
    http://www.welserver.com/index.htm . It's the one I use. I live in the same DFW area as you. Here's an example of my attic using...
  21. Replies
    34
    Views
    2,366

    Chris, your time/effort to respond is much...

    Chris, your time/effort to respond is much appreciated.

    I'm going to pursue the link you provided - this is very helpful. Thanks.

    For my actual installation, perhaps I can find someone who...
  22. Replies
    34
    Views
    2,366

    I believe the 68° deep earth temp is what it...

    I believe the 68° deep earth temp is what it would be only if heat wasn't being dumped into the earth. In my case, at the moment, I'm dumping about 650 KBTU/day, or about 20 MBTU/month, into the...
  23. Replies
    34
    Views
    2,366

    I agree, but don't know why. My EWT at the...

    I agree, but don't know why.

    My EWT at the moment ranges from 76 - 84F, depending on time of day and/or amount of heat being rejected (about 750 KBTU per day, at about a 30 - 82 KBTU/hr rate). ...
  24. Replies
    34
    Views
    2,366

    Bob, in general, the DeSuperHeater option on your...

    Bob, in general, the DeSuperHeater option on your GSHP unit is only operational (i.e., heats water) when the your GSHP unit is running - i.e., water loop pump(s), compressor and blower.

    The temp...
  25. Replies
    33
    Views
    6,580

    My opinions: 1. Clearly, don't put it in,...

    My opinions:

    1. Clearly, don't put it in, spending tens of thousands of dollars, until you've found a contractor you're comfortable with.

    2. Increase your chances of finding a contractor you're...