  1. If you look at the schedule object, navigate to...

    If you look at the schedule object, navigate to the scheduled items in the navigation mode. Make sure that the occupied command which is I believe bd227 in the UNT controller is there. If so, then...
  2. Just because you swapped the sensor does not mean...

    Just because you swapped the sensor does not mean the wiring is not bad from the controller to the sensor. If it works in commissioning mode and not in the jace you have a jace issue.
  3. Silly question but did you ohm out the sensor...

    Silly question but did you ohm out the sensor from the wiring at the controller to confirm there are no issues with wiring. This line of controllers is pretty bullet proof to use. Next question, if...
  4. Ended up changing out the PC with Win7-32 bit pro...

    Ended up changing out the PC with Win7-32 bit pro version. No more problems and never did find out what was causing this.
  5. Replies
    9
    Views
    399

    It must be selected as exp 4di4do, it is on the...

    It must be selected as exp 4di4do, it is on the bottom of the selection drop down.
  6. Replies
    9
    Views
    399

    If you selected the xp as xp 4di 4do then you...

    If you selected the xp as xp 4di 4do then you will also need an XT module. If you open up the module for this you will see a configuration for the module in which you need to set an N2 address. IF...
  7. Replies
    9
    Views
    399

    When you selected the second module how dud you...

    When you selected the second module how dud you select it? The first module would be selected as the xp 6a12ao and the second module must be selected as exp......
    If not you are adding another...
  8. Metasys GGT Graphics not displaying on Win XP

    Hello, I am working on a Metasys system with GGT graphics. The issue is one XP machine will not display the graphics, just a plain greay/white screen. If I restart Metasys I might get one GGT...
  9. Replies
    14
    Views
    786

    We have an issue that is similar, we lose...

    We have an issue that is similar, we lose connectivity to the device every few days as out IT dept does maintenance. A firewall reload for instance causes about a 5 minute outage to that device. I...
  10. Replies
    14
    Views
    786

    Are these on a managed network or are they on a...

    Are these on a managed network or are they on a private network? If they are managed check with IT to see if there is something being done with firewall maintenance or some other reload or testing...
  11. Honeywell Solid State Current Valve (SCR)

    Hi All, I am looking for info on this device part# R7425A1017. It is an old Honeywell SCR and cannot find literature online or by contacting Honeywell. It was connected to old H'well controls...
  12. Yes it is.

    Yes it is.
  13. I worked there for 8 years as a Systems Rep, DDC...

    I worked there for 8 years as a Systems Rep, DDC tech. It is a great place to learn and take it for what it is. JCI is a large multi-national company that looks out for its shareholders before...
  14. Replies
    4
    Views
    411

    In MSEA, you can use LCT/Interlock/Global etc. to...

    In MSEA, you can use LCT/Interlock/Global etc. to write to an analogue input as long as it is not on a DX-9100 controller. There are a couple of ways to do it. The most simple is to put the input...
  15. Replies
    0
    Views
    219

    Metasys and Pegasys Integration

    Hello, we have these two integrated together and under the ADX I can see the Pegasys Server and it's points. However, I cannot add extensions to the individual point in order to trend or alarm...
  16. Interfacing Reliable Mach-1 Controller into a JCI NCE controller

    Hello, I have a customer with several sites with Reliable Mach-1 controls with at least one site with a Mach-Global controller. All devices have network enabled communications that he is able to...
  17. Hi, we have over 350 of these in one of our...

    Hi, we have over 350 of these in one of our buildings. We used Johnson VMA controllers, the N2 type, and left the pneumatics in place. We were able to control both the mixing of the hot and cold...
  18. Try this out from Greystone,...

    Try this out from Greystone,
    http://greystoneenergy.com/webcura/files/247807_gt_ares_spec.pdf
  19. Replies
    6
    Views
    1,233

    JCI will sell to a building owner and this is...

    JCI will sell to a building owner and this is part of the SCT tools which would include the database/offline programming tools for the MSEA, HVACpro, GX-9100 and of course the CCT Tools.
  20. Metasys MSEA to Edwards Quick Start Panel Integration

    Looking to integrate the two systems on an LAN as we wish to see all of the devices on the Edwards Quick Start Panel.

    Has anyone done this or have guidance other then using a fieldserver box?
    ...
  21. Replies
    14
    Views
    1,612

    Hi, if you do not have the DX key for the editing...

    Hi, if you do not have the DX key for the editing of paramaters in the DX you can use a small jumper or set of needle nose pliers. The "key" essentially jumps the top and bottom pins of the plug...
  22. Replies
    1
    Views
    482

    It must be brought in through an NAE and a Bacnet...

    It must be brought in through an NAE and a Bacnet integration and the NAE will discover the points.
  23. Replies
    12
    Views
    1,030

    Hi Integrator, check to ensure that IT has not...

    Hi Integrator, check to ensure that IT has not blocked anything. Is the ADS behind a firewall? We have had the same issues but found that IT had to make modifications to all ports for each PC being...
  24. Replies
    9
    Views
    652

    JCI is stopping production of all N2 devices from...

    JCI is stopping production of all N2 devices from that era of controllers. They apparently are replacing them with an FEC that will communicate on the N2.

    Role the dice on this one. The UNT is...
  25. Replies
    2
    Views
    375

    Is there any chance it got added into a schedule?

    Is there any chance it got added into a schedule?