    That is a picture of a louvre, not a damper. The...

    That is a picture of a louvre, not a damper. The difference? a louvre is immovable.
  2. Replies
    9
    Views
    1,049

    Your "Schnieder" thermostat is most certainly...

    Your "Schnieder" thermostat is most certainly manufactured by Viconics, a company out of Canada. (Viconics Model VT7600) They make that one as well as several other companies that put their own...
  3. Replies
    3
    Views
    286

    The computer running the WebCtrl Server software...

    The computer running the WebCtrl Server software should have all of the help files on them. Those may be accessed from within WebCtrl or from the start menu. Good luck.
  4. Replies
    2
    Views
    318

    "Heat Loss" is usually thought of as the amount...

    "Heat Loss" is usually thought of as the amount of heat that dissipates or transfers from inside a building or structure to the outside of that structure. What exactly are you looking for? I...
  5. Replies
    14
    Views
    713

    I'm just not picturing it. Can you give a little...

    I'm just not picturing it. Can you give a little more information? Are they Mod Motors, Pneumatic actuators or Belimo Motors running the damper rod? Can you disconnect the rod from the actuator and...
  6. Replies
    3
    Views
    434

    I was hired many years ago to remove electrical,...

    I was hired many years ago to remove electrical, pneumatic controls and sheet metal to several rooftop units at a local school. The roofers lifted the units, reroofed (adding about 6" foam to flat...
  7. Replies
    1
    Views
    368

    I just installed some Venstar t-stats and I...

    I just installed some Venstar t-stats and I really like them. You can make them do almost anything and the Internet hookup is very user friendly. I installed the app on PC, Iphone and android and it...
  8. Replies
    7
    Views
    537

    Hello... Is your cooler walking? You better go...

    Hello... Is your cooler walking?
    You better go catch it!!!
    Ha ha ha.


    Classic!
  9. Replies
    2
    Views
    312

    I have 30 or so SA Tux and about the same of VAV...

    I have 30 or so SA Tux and about the same of VAV Tux as well as an APEX or two if that would help you out. I also have 50 or so Sensors to go with them
    PM me if interested
  10. Replies
    9
    Views
    517

    I went with the Venstar T6800 Commercial Tstat....

    I went with the Venstar T6800 Commercial Tstat. It has the keyboard lockout I wanted, I-phone and Android compatible and is purty!
  11. Replies
    21
    Views
    1,513

    My apologies Timebuilder. I thought it was...

    My apologies Timebuilder. I thought it was approriate in Tech to Tech and I did not specify, due to the reasons you mentioned, but gave minimum wire size.
    My point was that it was possible that the...
  12. Replies
    21
    Views
    1,513

    MenTen, If your setup is what I think it is...

    MenTen,
    If your setup is what I think it is you have an indoor furnace with electric heat. Yes? If so, the electric heat will quite often have its own electrical requirements seperate from the...
  13. Replies
    47
    Views
    2,646

    Deer Stag Work Shoes. Most comfortable utility...

    Deer Stag Work Shoes. Most comfortable utility shoe I've ever worn. Not steel toed but good overall wearability.
  14. Replies
    9
    Views
    517

    Great minds...:cheers:

    Great minds...:cheers:
  15. Replies
    9
    Views
    517

    It looks likie I might be changing the 2-cond...

    It looks likie I might be changing the 2-cond t-stat wire to 4-cond to get the common down to the stat. Easy enough in an open hangar.
  16. Replies
    9
    Views
    517

    Thanks for the link Crab. I cant use the Vision...

    Thanks for the link Crab. I cant use the Vision Pro because it requires a common, which I wont have with the hanging heaters. It looks like the one you bought might work.
  17. Replies
    9
    Views
    517

    Exactly what I needed to know, thanks Dad.

    Exactly what I needed to know, thanks Dad.
  18. Replies
    9
    Views
    517

    WiFi Thermostat needed.

    I need to reccomend a wifi solution to our local Airport Board today. The problem is that our heating bills are way too high because at our airport there is no staff on site, so people come in, turn...
  19. Replies
    28
    Views
    1,509

    I am suprised I have to respond to this second...

    I am suprised I have to respond to this second opinion, but I will.
    You say the refrigerant migrates to the coldest spot. So.. In my stated scenario, the ambient temp at the evap is 100 deg F. If...
  20. Replies
    28
    Views
    1,509

    OK, If the evaporator coil is sitting above the...

    OK, If the evaporator coil is sitting above the furnace and the ambient tempurature is 100 deg F, like it is quite often throughout the country, and the compressor is NOT running, what is the...
  21. Replies
    28
    Views
    1,509

    Please notice the max working pressure. 300psi...

    Please notice the max working pressure. 300psi MAX. R410A at 100 degrees is higher than that and therefore this coil needs to be changed. Period. And the fact that there is tape there may not mean...
  22. Holy Crap! I thought "That's alot a money for a...

    Holy Crap! I thought "That's alot a money for a cap!" Then I realized it was for the whole service call. In which case it's awfully cheap!
  23. Replies
    28
    Views
    1,509

    The OP does not understand that there is only one...

    The OP does not understand that there is only one refrigerant in the system. If he thinks there are two different ones it would make sense he heard this from the contractor, in my opinion.
  24. Replies
    7
    Views
    584

    It is incorrect and should be corrected.

    It is incorrect and should be corrected.
  25. Replies
    2
    Views
    312

    I would have to think that the web based...

    I would have to think that the web based tempurature would be more accurate than a local sensor. It is pretty easy to put a sensor in the wrong place. ie: south side of the building or against a dark...