  1. Replies
    14
    Views
    834

    in the Niagara points manager of the folder for...

    in the Niagara points manager of the folder for rtu4 highlight all points and click edit at the bottom , then click the search button at the end of the point id row , then search for rtu3 then...
  2. Replies
    2
    Views
    158

    Trane chiller lon card

    R2 to Ax conversion with 2 trane centrificals , both with lon cards , prior contractor only wired lon network to chillers-no start/stop relays , 1 chiller will except start command through the lon...
  3. Replies
    15
    Views
    982

    One solution to your problem would be to...

    One solution to your problem would be to disconnect the andover system and log into the d-bacs through there setup software and command them off and see if your strange problems stay or goes , that...
  4. Replies
    5
    Views
    443

    If your going to leave the NAE's and bring them...

    If your going to leave the NAE's and bring them in B/IP into the supervisor , remember you have to buy those point blocks and you need to have sct to change default network numbers as they may all be...
  5. Thread: JCI AHU-101

    by chuz
    Replies
    6
    Views
    470

    after the balance company sets the min , the new...

    after the balance company sets the min , the new settings have to be saved and redownloaded to the controller , if they did this then I would check to see where your outdoor air temp is coming from
  6. Replies
    1
    Views
    549

    TRANE CVHE UC800 BACNET/LON

    Does anyone know whether a uc800 can communicate bacnet mstp if there is a lon card installed ? Does enabling the lon card disable the bacnet interface? Thanks in advance
  7. Thread: Nae device id

    by chuz
    Replies
    2
    Views
    275

    Nae device id

    Can anyone help explain how to change the device id on an NAE. I don't have cct , i hope it can be done through the browser. Bringing in multiple NAE's into AX and have duplicate device id's...
  8. Replies
    8
    Views
    1,059

    No , still not having any luck. If I understand...

    No , still not having any luck. If I understand correctly , the virtual com port that is setup during the tunnel service installation , listed in control panel , needs to match the com port that is...
  9. Replies
    8
    Views
    1,059

    AX Serial Tunneling

    could someone help me out setting up serial tunneling on a jace 6. I have read the document several times and i cannot make a connection via the serial tunnel. I have the jars installed , installed...
  10. Replies
    7
    Views
    579

    had this same thing happen a week ago , my...

    had this same thing happen a week ago , my problem ended up being in web services the authentication was on "cookie digest" , I changed it to "cookie" and it would allow login from a browser. Now I...
  11. Thread: Flow meter/switch

    by chuz
    Replies
    6
    Views
    588

    might look into the efector/IFM flow...

    might look into the efector/IFM flow switch/meter. i have had good success with them, and some oem's are using them.
  12. Replies
    1
    Views
    392

    Modbus Badger water meter

    Has anyone done a integration from a M-2000 Badger water meter into AX ? I have my network setup and have the address' online but every register i use brings back the same info or a fault. We are...
  13. Replies
    6
    Views
    708

    Thanks for the replies , i think that will do the...

    Thanks for the replies , i think that will do the trick. I usually do the pop up when i go to trends from a single px for a plant or something , but haven't had to do it from relativized px.
  14. Replies
    6
    Views
    708

    AX Hyperlink to trend

    can someone tell me if you can create a hyperlink to a trend from a px used for 50 devices ? I have set this up this but every device links to the same trend. All of my device graphics are...
  15. Replies
    2
    Views
    553

    daikin

    Bill , the reason the temps arent the same is because the system uses the sensor in the cassette by default , but you can change the setup and use the wall sensor. Dont know if you have noticed but...
  16. Replies
    15
    Views
    2,405

    Robert, i'm not 100% sure but i dont think...

    Robert, i'm not 100% sure but i dont think hvac-pro will work with the "FA" controllers. I think pro can only be used with "SA" controllers, you might check the other ones on your existing network...
  17. Replies
    5
    Views
    1,432

    seimens has a smart II driver for a tridium ax...

    seimens has a smart II driver for a tridium ax jace through there Talon line , I have done one of these integrations , luckily the installing contractor left good records and point lists.
  18. Replies
    3
    Views
    1,086

    thanks, Digo , it looks like you have seen that...

    thanks, Digo , it looks like you have seen that question before :)
  19. Replies
    3
    Views
    1,086

    ax supervisor heap

    anybody know if you can increase the amount of java heap in a supervisor and if so how ? I have 39 mb of free heap left and about 90 vav's left to bring in.
  20. Replies
    31
    Views
    1,503

    many thanks for the replies, i too, believe that...

    many thanks for the replies, i too, believe that the jace has the memory in it you just have to pay to enable it , kinda stinks , especially when you are trying to convince your new employer that...
  21. Replies
    31
    Views
    1,503

    extended memory in jace

    anyone care to comment on what benefit adding the extra 128mb of extended memory has on an fx-60, is it for added graphics , speed , more controllers , more data logging , or what?? any info will be...
  22. Replies
    9
    Views
    1,242

    mammoth

    had this very problem on mammoth unit that replaced old lennox dms units. it ended up being the module inside the modutrol motor. when we ordered and picked up the new module i noticed the 2 where...
  23. Replies
    16
    Views
    1,306

    that controller sounds like xl15c plant...

    that controller sounds like xl15c plant controller, if it unplugs for the base,dont remember any xl10's that unplug. the programming is the same though, we use lonspec
  24. Replies
    9
    Views
    953

    you might look into the honeywell t7350M. pretty...

    you might look into the honeywell t7350M. pretty flexible with modulating outputs and configurable stage outputs , lon based communicating but kinda pricey.
  25. Thread: network question

    by chuz
    Replies
    11
    Views
    858

    thanks for the responses , cant do wireless . job...

    thanks for the responses , cant do wireless . job spec says dsl modem and dslam? wiring will be a twisted pair and will go from "a" building to workstation building , "b" building to workstation...