  1. Replies
    9
    Views
    691

    SCtech33, I'm sorry to hear you've had bad luck...

    SCtech33, I'm sorry to hear you've had bad luck with your unit. We would love to get it working for you, give our technical service line a call to get someone here in Syracuse, NY to help you! You...
  2. Replies
    9
    Views
    691

    1

    1
  3. Replies
    13
    Views
    2,038

    INFICON GAS-Mate

    Good afternoon!

    In regards to combustible gas sensitivity, the best detector in the industry is the INFICON GAS-Mate. The GAS-Mate is TWICE as sensitive as the closest competitor, operates on 2 D...
  4. Replies
    2
    Views
    631

    Good afternoon, In regards to this situation I...

    Good afternoon,

    In regards to this situation I do not think you have a leak in your vacuum gauge. 1 microns every 20 seconds is an acceptable rise for the setup you have. I would be concerned if...
  5. Replies
    13
    Views
    1,472

    Good afternoon! I can help you on both your...

    Good afternoon!

    I can help you on both your complaints with the INFICON Scale.

    We make a case that you can store he unit in with out having disconnect the handpiece (part nuber 713-703-G1). ...
  6. Replies
    69
    Views
    20,544

    Poll: Using the set points (hi med low) changes the...

    Using the set points (hi med low) changes the sensitivity to detect predetermined leak rates, and this combined with the auto zero function is very similar to the manual zero. When using the manual...
  7. Replies
    69
    Views
    20,544

    Poll: The auto zero function automatically zeros to the...

    The auto zero function automatically zeros to the ambient conditions every 7 seconds. This means that the level of refrigerant that the unit is sensing will be the new base point, and anything below...
  8. Replies
    69
    Views
    20,544

    Poll: The D-TEK Select has an auto calibrated self...

    The D-TEK Select has an auto calibrated self check system when it starts. When you need a new sensor, the unit will tell you by flashing all of the orange lights on and off. From a feasible time...
  9. Replies
    69
    Views
    20,544

    Poll: Refrigerant Leak Detector Technology

    Good morning guys! I just wanted to throw in some information in this thread for the sensor technology. The first leak detectors where the Corona suppression and surface reaction. These sensor...
  10. Replies
    31
    Views
    5,316

    Contact

    Please take a look at our profile for our e-mail address. Look forward to hearing from you soon!
  11. Replies
    31
    Views
    5,316

    Please e-mail me at I understand you may be...

    Please e-mail me at I understand you may be trying to help but all email addresses must go in your profile otherwise the BOTS crawl the site and slow it down, considerably. We look forward to hearing...
  12. Replies
    31
    Views
    5,316

    Good afternoon, I have read your post, and as...

    Good afternoon,

    I have read your post, and as a reprasentative of INFICON I would like help you out if you are still in need of a D-TEK Select. Please respond to me so that we can get you squared...