  1. Replies
    11
    Views
    675

    Thank u sir !! I ll post results in a few days

    Thank u sir !! I ll post results in a few days
  2. Replies
    11
    Views
    675

    You the man ice !!! I think we got a winner . It...

    You the man ice !!! I think we got a winner . It should be the NEBCH8 / double curved glass case .
  3. Replies
    11
    Views
    675

    Yes ice . It's curved glasses. With evaporator...

    Yes ice . It's curved glasses. With evaporator fans . No condensing unit yet . The txv is R404a . I ll try to contact the supplier for more info tomorrow. Thanks for all the supports.
  4. Replies
    11
    Views
    675

    Thanks iceman . Looks like I'm doomed . This is...

    Thanks iceman . Looks like I'm doomed . This is a refurbished case . 2 ◊8' sections with efse 1/2 -c txv .
  5. Replies
    11
    Views
    675

    It's gonna be indoor 75* ambient . R404a

    It's gonna be indoor 75* ambient . R404a
  6. Replies
    11
    Views
    675

    Hussmann deli case

    Hussmann
    Ardco Temperbent
    ANSI Z97-1-1984
    16 CFR 1201-CII

    need to size up a condensing unit for the case . Any help would be greatly appreciated! !
  7. I was told by a Panasonic instructor that filter...

    I was told by a Panasonic instructor that filter driers will act as restriction in the system in mini splits . Even a slight restriction Will be a problem .
  8. Replies
    17
    Views
    1,954

    I would also like them

    I would also like them
  9. Replies
    10
    Views
    1,427

    I got lucky on this one . took off the top of the...

    I got lucky on this one . took off the top of the box wiggle it out . Went pretty well . Thanks !!!
  10. Replies
    10
    Views
    1,427

    I ll bust out my Sawzall later . Appreciate all...

    I ll bust out my Sawzall later . Appreciate all the responses.
  11. Replies
    10
    Views
    1,427

    what happened was . This air handler is suspended...

    what happened was . This air handler is suspended in the ceiling of a supermarket. Some contractor builded a wall around it
  12. Replies
    10
    Views
    1,427

    I have a wall right in the middle of the access ....

    I have a wall right in the middle of the access . If I could pull it out . Might as well put in a new kit
  13. Replies
    10
    Views
    1,427

    Well . I have just enough room to stick my leads...

    Well . I have just enough room to stick my leads in . Not enough to pull out the pack . I have voltage but 0 amp . Not even sure I can pull the blower either
  14. Replies
    10
    Views
    1,427

    trane heat kit question

    BAYHTRL325A
    has anyone replaced the fuse links inside this heat kit ?
    my options are either cut a hole in the wall to pull out the heat kit . or try to remove the plenum to change the fuse links...
  15. Replies
    21
    Views
    3,409

    Check the jumper . Be sure it's in numbered...

    Check the jumper . Be sure it's in numbered position. It won't energize if left in p
  16. Thread: bluvac

    by chow foon
    Replies
    20
    Views
    2,667

    Thanks man. I enjoyed using it very much . Either...

    Thanks man. I enjoyed using it very much . Either have it fixed or get a new one
  17. Thread: bluvac

    by chow foon
    Replies
    20
    Views
    2,667

    bluvac

    My bluvac just took a dump on me . It won't turn on . Even with a new battery. Any suggestions?
  18. Replies
    23
    Views
    3,891

    I had a 1hp plugged up 3 driers in less than 2...

    I had a 1hp plugged up 3 driers in less than 2 wks !! The compressor finally seized up after the 3rd drier . God knows what was in the system .
  19. Replies
    6
    Views
    1,000

    Magnet wasnt too bad . I got it going b4 I clean...

    Magnet wasnt too bad . I got it going b4 I clean it
  20. Replies
    6
    Views
    1,000

    Put in new bin switch . fires right up . but how...

    Put in new bin switch . fires right up . but how did it fail because I turn it off ?anyway , its working . watch it made 4 batches after I gave it a clean . thanks again 2sac .
  21. Replies
    6
    Views
    1,000

    No codes . I looked many many times . but the bin...

    No codes . I looked many many times . but the bin light would cycle on and off when I move the damper . checked all electrical connections already. Will go back to clean the machine + check on bin...
  22. Replies
    6
    Views
    1,000

    No codes . I looked many many times . but the bin...

    No codes . I looked many many times . but the bin light would cycle on and off when I move the damper . checked all electrical connections already. Will go back to clean the machine + check on bin...
  23. Replies
    6
    Views
    1,000

    manitowoc wont go into freeze

    Under counter unit QD0132a won't go into freeze . original complain was low ice production. Adjusted itp . turned it off to check flow valve . turned back on . now won't freeze . only water pump...
  24. Thread: Evacuation

    by chow foon
    Replies
    16
    Views
    3,394

    my appion core tool leaks .. i experienced the...

    my appion core tool leaks .. i experienced the exact fluctuation at least 2 times with the appion core tool , now i just wont use it
  25. Replies
    7
    Views
    1,618

    You r a good man dawg :bump:

    You r a good man dawg :bump:
  26. Replies
    26
    Views
    4,393

    ditto .. Makita is the shizit !!!

    ditto .. Makita is the shizit !!!
  27. Replies
    14
    Views
    1,879

    mine was easy , i met the coca cola guys , had 2...

    mine was easy , i met the coca cola guys , had 2 guys lift the ice machine up, they slide old one out, slide in new one in, they didn't even really need me there..
  28. Replies
    40
    Views
    5,385

    Thanks ! Coulda use one yesterday

    Thanks ! Coulda use one yesterday
  29. Replies
    40
    Views
    5,385

    where can i get one of these svom 18 ? i searched...

    where can i get one of these svom 18 ? i searched everywhere .. but can't find nada ..
  30. Replies
    3
    Views
    1,047

    Take it to your local supply house . Cost u a few...

    Take it to your local supply house . Cost u a few bucks to recycle it
  31. Replies
    3
    Views
    1,047

    do u mean recovered ?

    do u mean recovered ?
  32. Replies
    14
    Views
    1,879

    thanks a lot fellows

    thanks a lot fellows
  33. Replies
    14
    Views
    1,879

    take the whole machine down then put on top of...

    take the whole machine down then put on top of new machine
  34. Replies
    14
    Views
    1,879

    ice machine disassemble

    howdy, I'm fairly new to ice machine and refrigeration.. was just asked to disassemble an ice machine on top of a coke machine till coca cola swap out a new one then put it back .. model of ice...
  35. Replies
    24
    Views
    11,041

    im not exactly sure now . but i got 50 after i...

    im not exactly sure now . but i got 50 after i reset it. can't remember exactly if i reset from the control board or interrupted the power .. shrug
  36. Replies
    24
    Views
    11,041

    its kinda rusted , but i couldn't see any cracks...

    its kinda rusted , but i couldn't see any cracks .. replaced hx in one of the units last year .. they r pretty easy to spot ..
  37. Replies
    24
    Views
    11,041

    thanks for the heads up.. already removed 1...

    thanks for the heads up.. already removed 1 return plenum to a cooler area ..
  38. Replies
    24
    Views
    11,041

    58 or 59 is gas valve not energized after 2 mins...

    58 or 59 is gas valve not energized after 2 mins . because the main limit is opened due to over heating in my case .. u could either reset on the control board or open the disconnect . i got a 50...
  39. Replies
    24
    Views
    11,041

    u will get a 50 when u reset the main breaker...

    u will get a 50 when u reset the main breaker when u get 58 or 59
  40. Replies
    24
    Views
    11,041

    so what happened was the returns are located at...

    so what happened was the returns are located at about 4 feet higher part of the ceiling.. so its like a hot pocket that provided 90 + degrees of return air , bumped the supply up to about 140 deg ....
  41. Replies
    24
    Views
    11,041

    i am experiencing the exact problem/same unit.....

    i am experiencing the exact problem/same unit.. found my fan belt was extremely loose .. plus the blower motor pulley is pretty worn out.. fan blower pulls 6.6 amps .. fla 10 amps. changing out...
  42. Replies
    13
    Views
    2,167

    Goodman can supply u a piston for your 3 ton 10...

    Goodman can supply u a piston for your 3 ton 10 seer condenser. For like $ 6-7
Results 1 to 42 of 47