  1. Thanks

    Thanks for the info - I verfied this with the manufacture.
  2. Replies
    0
    Views
    223

    ECB_VAVS upgrade

    Hello,

    We have upgraded couple of our VAV controllers and EC-Smart-Vue to the newer firmware. We now notice that in the Device Extensions we no longer see the EC-Smart-Vue?
    Has anyone come...
  3. The object was brought in as an AV. No other...

    The object was brought in as an AV. No other option.
    The niagara object is an AV which we can command (set). Once brought into the export folder, we dont have the action option.
    The BACNET user is...
  4. Tridium BACnet Export Folder = BACnet Writable "no"

    Hello,

    We are exporting BACnet objects from the Niagara Network to BACnet. But for some reason and I don't know why, the point in the Niagara is commandable (Setpoint) but once we export it the...
  5. Replies
    1
    Views
    367

    Distech and AX question

    Hello to all

    gfx question:
    The default of a set command is at priority 14. I see in the gfx program the location of this value. If we change this in the gfx program, will it be the norm for this...
  6. Replies
    3
    Views
    510

    gfx program - counter

    Hello,

    I'm in need of a program (ideas) on a counter that would count every 5-10 seconds increment a AV to 100 and reset. Not sure what block in the DIstech gfx program would do this.

    Thanks...
  7. Replies
    1
    Views
    542

    ICG Ultimate 2 manual

    Hello,
    We have a ICG Ultimate 2 furance that we are looking for the manual on. I can't locate anything on the web which is really odd!! Would anyone have access to a pdf that they can share.
    ...
  8. Replies
    4
    Views
    454

    Thanks

    Thanks on this, using NTFS symbolic link - aka symlink would be the easiest until we redo the machine.
  9. Replies
    4
    Views
    454

    WOW

    So this is the only way to direct trends from the C: drive?

    Thanks
  10. Replies
    4
    Views
    454

    AX - History Location

    Hello,

    On our AX server, we have three(3) parition drives. The Niagara folder was installed on the C Drive with the trends etc... being saved here. Well this has placed the C drive full.
    Is...
  11. Replies
    0
    Views
    272

    AX BACnet COV "Black Magic"

    Hello,

    We are setting up 8 BACnet COV subscriptions per controller. When we view the points, the objects in question say COV. Is there someplace in the AX which tells me which device these COV are...
  12. Replies
    3
    Views
    507

    1) Right-click My Computer and select Manage. 2)...

    1) Right-click My Computer and select Manage.
    2) Expand Services and Applications, then Message Queuing.
    3) Select Private Queues

    A list will appear in the right pane, ensure that all numbers...
  13. Replies
    3
    Views
    507

    Version

    What's the version of the system. The problem is that certain trends are not being processed. Once you tell me the version we can look into a fix.
  14. Distech Alarms to 3rd party BACnet device

    Hello,
    We have a Distech system with several EC-Bos controllers at 3.x. with a server. We are planning to send some of the alarms to a 3rd party BACnet/IP device.
    Do we need to add a...
  15. Replies
    5
    Views
    555

    Bluetooth

    You can only download \ upload using the CCT with the CVT connected to the SA\FEC bus using bluetooth. I've done this several times and it worked fine.
  16. Sorry - the COV is in the point object focus tab....

    Sorry - the COV is in the point object focus tab. If it doesn't have a number add one in. If it does, increase it a bit. Some 3rd party objects might not support COV, I think the TEC are like this so...
  17. also change 3 to 6

    also change 3 to 6
  18. TEC

    TEC are 3rd party devices. If you look at one of your MSTP pages, you'll see polled Object Count. This is the # of 3rd party devices which are polled and don't support COV or are not enabled. Change...
  19. COV

    WOW
    First I would increase the APDU etc. Then as JCIMAN mention, "MAKE SURE" all of your objects are COV which will elimiate the polling on the MSTP bus.

    If you still have issues, we can change...
  20. Increase the MSTP time

    Try and increase the MSTP bus times -> go under the focus tab and adjust the following;

    APDU Timeout is the length of time the NAE will wait before sending a retry if no reply to the request has...
  21. Replies
    6
    Views
    834

    Well it's actually http://swftec.com/GPG03.htm

    Well it's actually http://swftec.com/GPG03.htm
  22. Replies
    6
    Views
    834

    Found the program http://swftec.com/index.htm ...

    Found the program
    http://swftec.com/index.htm

    This is a custom program that allows you to work outside of the "Box"
  23. Replies
    6
    Views
    834

    JCI HVACpro text program

    Hello,
    I'm trying to find the text program someone wrote to access the johnson controls VAV \ UNT controllers.

    Can anyone remember the link in this site or the name

    Thanks
  24. Hope this worked

    Here's the doc
  25. Found the document and yup - 2 is the deivce ID....

    Found the document and yup - 2 is the deivce ID. Once I figure out how to attach an document, I'll post it which will help in the integration. what I was thinking of at the end of the string is @15
  26. Who did the intergation? bacnet://2/AO:2172 are...

    Who did the intergation? bacnet://2/AO:2172 are you reading this from the AO string in Webcontrol?? Change the //2 to //16 in Webcontrol and see if you can override at 15.
    In Webcontrol you can add...
  27. Replies
    21
    Views
    3,204

    Within the Metasys world they use a different...

    Within the Metasys world they use a different method to communicate to each other. That's why you have all the BACnet ID @ 500 which is the default. BUT if you were to BACnet these into another...
  28. Replies
    4
    Views
    943

    What version

    What version
  29. Open up the FEC (MSTP) bus in the focus window....

    Open up the FEC (MSTP) bus in the focus window. Click on the engineering tab and do I scan. Does it find anything?

    Then click on the Diagnostic tab and click on the Advance bullet. Do a screen...
  30. Replies
    2
    Views
    590

    There are two types of N30s: the original N30-0...

    There are two types of N30s: the original N30-0 and the new N30-1. Choose the one in Project Builder that matches your hardware.

    The primary difference between the two models is the amount of...
  31. Replies
    20
    Views
    3,908

    Not a problem - BACnet and BBMD are one of the...

    Not a problem - BACnet and BBMD are one of the biggest misunderstanding people have. I've been luckly to work on several BACnet/OPC projects writing code etc to gain this understanding (lots of head...
  32. Replies
    20
    Views
    3,908

    - Depending on how to you ask for information....

    - Depending on how to you ask for information. For example, the software program by Chipkin "BACnet Explorer" uses Device ID and 47808. This brings back all the BACnet/IP devices on the system.

    -...
  33. Replies
    20
    Views
    3,908

    Once I figure out how to attach my screen shot -...

    Once I figure out how to attach my screen shot - it shows the NCE BACnet site as False and using Chipman BACnet/IP Explorer finding the NCE with objects on the network - so the site does not need to...
  34. Replies
    51
    Views
    8,808

    Can't post pictures - what's up THanks

    Can't post pictures - what's up

    THanks
  35. Replies
    6
    Views
    739

    We used around 15 of the S2N2E device over our...

    We used around 15 of the S2N2E device over our network. Sam stands behind his product and worked with us.

    The only draw back is that you can't download the N2 devices over the S2N2E - unless he...
  36. Replies
    20
    Views
    3,908

    Straight from JCI engineer: The NxE is...

    Straight from JCI engineer:

    The NxE is discoverable by default, nothing special is required to enable it to be discoverable.

    So here is some information on what to look for \ change

    The...
  37. Replies
    20
    Views
    3,908

    fdefoy, Did you try the about. As stated, the...

    fdefoy,

    Did you try the about. As stated, the NAE is the BACnet/IP device. As of now, you have the ADS as the site manager in the NAE. If you disconnect the NAE from the ADS, and put the NAE as...
  38. Replies
    1
    Views
    428

    BACnet

    The NAE is BACnet/IP and not BACnet over Ethernet. So verify that KMC can communicate using BACnet/IP.

    Then in the NAE you will need to setup the BACnet intergration object which will allow the...
  39. Replies
    20
    Views
    3,908

    have you tried to talk with all the NAE's. By...

    have you tried to talk with all the NAE's. By default, the NAE is setup for BACnet/IP. There is nothing to setup except the deivce ID which is 500 by default.

    The ADS Server has nothing to do with...
  40. Replies
    20
    Views
    3,908

    In the NAE under the focus tab, you will have the...

    In the NAE under the focus tab, you will have the object ifentifiter which is 500 in your case. Also you have the 1001 network address.
    If you open the tree, do you see a BACnet object? should will...
  41. Replies
    20
    Views
    3,908

    NAE55

    Most likely all the NAE's have the device ID as 500. This is the default and 99.99 % of the time never gets changed.

    Second you communicate to the NAE not the ADS. Go into a NAE and from the Tree...
  42. Replies
    9
    Views
    744

    Hello, Installed after 2005, not sure on the...

    Hello,
    Installed after 2005, not sure on the extra year. When it's running, I do see some water coming from the evap coil. The furance is rated for 1200 CFM and based on Mr.Bill, 1 ton = 400 CFM I...
  43. Replies
    9
    Views
    744

    Hello, Checked the duct work all seems good. Not...

    Hello,
    Checked the duct work all seems good. Not sure what is manaul J & D are?? You can tell when the furance is on, as it's moving a lot of air though the duct work. I'll have to check on the...
  44. Replies
    9
    Views
    744

    Tempstar Furance and AC question

    Hello,
    We just purchased a home with a 2005 tempstar furance (T9MPV075F12B1) and AC unit (TXA224AKA2). From what I gather, this furance has multiple taps for the motor. The factory setting is high,...
  45. Replies
    1
    Views
    368

    stat or furance control board??

    Hello,

    Figured this would be a good place to start. I have a furance which runs all the time and does not shutdown. In cooling, the fan starts and then the AC. And it doesn't shutdown. Only when I...
  46. Replies
    10
    Views
    1,298

    N2 Bus

    Under the NAE, open the N2 bus in the main window. Click on the engineering tab. It might come up with a auto-discovery window say Yes. If it doesn't click on the Relean button. This will scan your...
  47. Paladin

    I guest it's as easy as pie!! Our electrians give us a Paladin tool which worked? And go figure it's a Time Design Reflectometer.
  48. Diasychain

    Good day to all.

    Thanks for the insight. To add onto this, we would disconnect every daisychain connections to the controllers. Then we need to get the distance between each controller and then...
  49. Tool to read the distance of a 2,3 or 4 wire cable.

    Hello,

    I'm looking for a device which willl allow us to read a 2, 3 or 4 wire daisychain communication run.

    We tried a $18K Fluke network tool and didn't like the daisychain. What would be...
  50. Are you using the fieldserver tools on your PC??...

    Are you using the fieldserver tools on your PC?? if not get these from the web and run the Remote User Interface program.

    Are you sure the IP in the fieldserver is correct? what is the sub and...