  1. thank you.

    thank you.
  2. post company name and/or website I will look...

    post company name and/or website

    I will look into it.
  3. Is that all it is?

    Is that all it is?
  4. Replies
    24
    Views
    1,454

    just say sure, no problem as long as the...

    just say sure, no problem

    as long as the employer provides 8hrs of continuous work.

    otherwise, shop time, wait time is on their bill.

    I just don't see why the customer is not being billed...
  5. Replies
    24
    Views
    1,454

    Anytime, I am with my company phone and van, I am...

    Anytime, I am with my company phone and van, I am on the clock, and therefore expect to be paid,,,,,,this is my office.

    I take a call on a sat, or after hours, I charge at the time of call till I...
  6. Replies
    9
    Views
    1,619

    you are looking for a .........COMPANY/BUSINESS

    you are looking for a .........COMPANY/BUSINESS
  7. Replies
    41
    Views
    3,071

    that issue is already been solved with heated...

    that issue is already been solved with heated receivers.....or bypass timers that energize comp contactors to build pressure to satisfy low press switches.
  8. Replies
    41
    Views
    3,071

    that device still uses a needle and seat, as best...

    that device still uses a needle and seat, as best I can see.

    that tends not to lead to linear proportional loading, as a stepper and tear drop setups do.

    I need to read more me thinks.:cheers:
  9. Replies
    41
    Views
    3,071

    interesting,,,,I am only familiar with EEVs. ...

    interesting,,,,I am only familiar with EEVs.

    with NO thermoelectric components, only a stepper motor.

    I will google these ETXVs..thankyou
  10. Replies
    41
    Views
    3,071

    what is an electronic TXV?

    what is an electronic TXV?
  11. Replies
    48
    Views
    3,267

    by the time board fails, the customer would have...

    by the time board fails, the customer would have saved 5 times that amount.:cheers:
  12. Replies
    41
    Views
    3,071

    this a fridge?

    this a fridge?
  13. Replies
    41
    Views
    3,071

    does the first one do anything, or is it gutted?

    does the first one do anything, or is it gutted?
  14. Thread: esc 201 board

    by indy2000
    Replies
    4
    Views
    685

    you still need info? if so, what specifically?...

    you still need info?

    if so, what specifically? contacts on the board?
  15. Replies
    41
    Views
    3,071

    in series or parallel? you sure its not ...

    in series or parallel?

    you sure its not de-super heating?
  16. Replies
    48
    Views
    3,267

    The cost benefit analysis has already been...

    The cost benefit analysis has already been done,,,,,,,,its going ahead, cause an EEV is able to perform where the TEV cannot.

    We have never had success with low/floating head with TEV, that is why...
  17. Replies
    48
    Views
    3,267

    with diminished capacity, yes you can go that...

    with diminished capacity, yes you can go that low.

    But you still must maintain subcooled liquid

    we are going to start at 60 and see if 50 SCT is feasible.
  18. Replies
    48
    Views
    3,267

    the energy cost will be the biggest piece. EEV...

    the energy cost will be the biggest piece.

    EEV don't require a particular pressure drop to maintain capacity, therefore do not need high head pressures, which reduces capacity..........

    lower...
  19. Replies
    48
    Views
    3,267

    what is the reason they stick to tev? I see...

    what is the reason they stick to tev?

    I see the contrary, especially with new demands on low refrigerant charges, and low condensing temps, and integrated monitoring systems, like the e2.
  20. Replies
    48
    Views
    3,267

    mostly emerson of late have used sporlan, in...

    mostly emerson of late

    have used sporlan, in many blast tunnels.
  21. Replies
    48
    Views
    3,267

    controller goes into elec cabinet temp sensor...

    controller goes into elec cabinet

    temp sensor and pressure transducer goes to evap.
  22. Thread: esc 201 board

    by indy2000
    Replies
    4
    Views
    685

    so?

    so?
  23. Replies
    48
    Views
    3,267

    the eev controller controls superheat to whatever...

    the eev controller controls superheat to whatever you set it for

    no more hanging out in a -20 freezer with frozen gauges and my sh66

    another benefit.....the eev does NOT rely on a solid column...
  24. Replies
    48
    Views
    3,267

    yes converting -20SST at 15TR, all to EEVs to...

    yes

    converting -20SST at 15TR, all to EEVs to utilize low condensing/floating head.

    these units are 2005 circa.
  25. Replies
    6
    Views
    1,053

    count me in!! thank you tranger03

    count me in!!
    thank you tranger03
  26. Replies
    48
    Views
    3,267

    time we all go to EEVs....these tevs are no match.

    time we all go to EEVs....these tevs are no match.
  27. Thread: esc 201 board

    by indy2000
    Replies
    4
    Views
    685

    have a lot of those in the field what oil...

    have a lot of those in the field

    what oil solenoid are you referring to, the return from the separator/ cooler?

    is this for a screw?
  28. Replies
    12
    Views
    1,025

    dtek select has allowed me to shelve the H10, I...

    dtek select has allowed me to shelve the H10, I liked it so much I have 2 in rotation
  29. Replies
    24
    Views
    2,639

    I agree.

    I agree.
  30. Replies
    24
    Views
    2,639

    Without a cell signal the function of the...

    Without a cell signal the function of the tracking/monitoring and updating devices are rendered useless.
  31. Replies
    24
    Views
    2,639

    ya know..... 'they' sell devices that hinder...

    ya know.....

    'they' sell devices that hinder the cell that is needed.........maybe$30 tops.......

    just saying...
  32. Replies
    62
    Views
    13,097

    was is the salary for naples?

    was is the salary for naples?
  33. Replies
    26
    Views
    6,351

    yes we build an exact device,,,,,,,,and we...

    yes

    we build an exact device,,,,,,,,and we call it a desuperheater

    sure is fun trying, to fix an install problem.....it starts to get to be a political.crap fest for some reason...

    i'll post...
  34. Replies
    26
    Views
    6,351

    belt drive, 60hp motor runs fully loaded below...

    belt drive, 60hp motor

    runs fully loaded below 20psig on suction

    external dx oil cooler shell and tube, 95deg set point

    run c3-s mineral oil

    I don't believe oil temp is too high, however...
  35. Replies
    26
    Views
    6,351

    rather eventful glad you came to solution ...

    rather eventful

    glad you came to solution

    having an issue with a f8k throwing excessive oil and high dis temp 255+

    took off the heads, took pics sent off to mycom, they say cylinders okay,...
  36. Replies
    26
    Views
    6,351

    How is the system running? any updates?

    How is the system running?

    any updates?
  37. Replies
    6
    Views
    549

    with a cap tube I would only be looking at evap...

    with a cap tube I would only be looking at evap superheat, once the correct charge is weighed in.

    and remember it can a long time for the system to reach stable equilibrium.
  38. Replies
    10
    Views
    1,357

    good luck

    good luck
  39. Replies
    31
    Views
    2,665

    How is that?

    How is that?
  40. Replies
    10
    Views
    1,357

    You have no standard rate of pay? I can link...

    You have no standard rate of pay?

    I can link you to our MIN pay scale, and you can tell me if you are close?
  41. Replies
    31
    Views
    2,665

    sight glass should be full and clear on hot pull...

    sight glass should be full and clear on hot pull down,,,its when it catches up to the load, the glass starts to flash.

    therefore if you are flashing on hot pull down you are undercharged

    also...
  42. Replies
    10
    Views
    1,357

    I do indust/commercial refrigeration. What is...

    I do indust/commercial refrigeration.

    What is the hourly pay and benefit package?
  43. Replies
    3
    Views
    1,104

    emailed you

    emailed you
  44. Replies
    409
    Views
    66,756

    is this a tiered system?

    is this a tiered system?
  45. Replies
    409
    Views
    66,756

    what is DVS,, mine reads BTJ?

    what is DVS,, mine reads BTJ?
  46. Replies
    409
    Views
    66,756

    What do figure the master plan is?

    What do figure the master plan is?
  47. Replies
    5
    Views
    763

    Good choice What size? What is the climate...

    Good choice

    What size?

    What is the climate like, ambient outside temps?
  48. Replies
    5
    Views
    763

    see that type liquid temp on all our low temp...

    see that type liquid temp on all our low temp screw packages

    its a way of increasing capacity of the expansion valves, not the evap.

    that is why the liquid line is always insulated.

    also...
  49. Replies
    90
    Views
    9,367

    Its 3 phase

    Its 3 phase
  50. Replies
    90
    Views
    9,367

    obviously the phase to phase short, only happened...

    obviously the phase to phase short, only happened when you were there?

    the breaker would have been tripped, prior to your arrival.