  1. Replies
    15
    Views
    2,265

    The whole "state law only requires" bit kind of...

    The whole "state law only requires" bit kind of threw me.
  2. Replies
    11
    Views
    2,296

    It sounds as though you may have a live heat...

    It sounds as though you may have a live heat strip still there.Another company should be able to find it.The power provider IS NOT going to tell you that the meter is screwed up.It's in their...
  3. Thread: WTF?

    by smngmu
    Replies
    12
    Views
    2,782

    I like the idea of holes in the door for...

    I like the idea of holes in the door for combustion air-then someone cover 'em up with foil tape.
  4. Replies
    14
    Views
    1,960

    I worked for a Goodman Dist before I left resi...

    I worked for a Goodman Dist before I left resi service.As stated,They don't have all the bells and whistles.Look at it this way.Take a brand new Caddi and run it for 200,000 miles and run a Buick for...
  5. Replies
    2
    Views
    555

    Yes,It's called SEER.10 SEER units are no longer...

    Yes,It's called SEER.10 SEER units are no longer allowed.R22 units will no longer be allowed as of soon.State and County ONLY OVERRIDE if sricter than Federal.Federal law rules.Does anyone else smell...
  6. Replies
    15
    Views
    6,380

    The reason I stated the SEER is that I've come...

    The reason I stated the SEER is that I've come across alot of coils that are no longer manufactured.The companies know you can't buy a certain item so they updated the line to eliminate the old.I'm...
  7. Replies
    15
    Views
    6,380

    A lot of the old 10 SEER equipment is gone.One of...

    A lot of the old 10 SEER equipment is gone.One of the home warrany companies that we deal with has given up on trying to find it.If they're stating it can't be found,they're probably right.
  8. Replies
    14
    Views
    4,865

    That's what scares me.There was no mention of the...

    That's what scares me.There was no mention of the attic access or catwalks so far.Had one house 2 weeks back.HO says there's a cat walk.There is.On the truss floor.AHU is ten feet above it.It was...
  9. Replies
    15
    Views
    5,108

    I think you're right.I seem to remember something...

    I think you're right.I seem to remember something about that in the install video.I think it was counter-clockwise south of the Equator.LOL
  10. Replies
    15
    Views
    2,162

    HVAC is the business.A/C is but one aspect of the...

    HVAC is the business.A/C is but one aspect of the whole.HVAC is used to signify persons schooled in Heating,Air Conditioning and Ventilation.Ventilation is the aspect of it that covers your duct...
  11. Thread: High Humidity

    by smngmu
    Replies
    29
    Views
    3,591

    Yes,your motor speed is too high.Yes,the charge...

    Yes,your motor speed is too high.Yes,the charge will have to be adjusted.Yes,you could do it yourself-BUT DON'T.It will void ALL warranties or worse.Yes,call the manufacturer directly and tell them...
  12. Replies
    2
    Views
    574

    IF designed right, you could theorectically ,...

    IF designed right, you could theorectically , close some down on seldom used rooms.Went to one house complaining of loud wind noise.New unit was way oversized for the house and over half of the...
  13. Replies
    18
    Views
    4,168

    They couldn't read.They just went by the...

    They couldn't read.They just went by the pictures.If you think about it,if you straddle it and look,it is verticle.hehehehe.
  14. Replies
    14
    Views
    4,865

    I heard it through the grapevine( not officially)...

    I heard it through the grapevine( not officially) that they will not be allowing RTU's in Clark County,Nevada on a two story structure as of Jan.08.Now if we could only condemn the half million that...
  15. Replies
    5
    Views
    934

    Your boss must be a real winner.I've NEVER...

    Your boss must be a real winner.I've NEVER changed a coil due to a bad TXV.I've changed some to accomidate some but never to fix one.
  16. A start kit WILL NOT prevent short cycling!!!If...

    A start kit WILL NOT prevent short cycling!!!If it is short cycling,that's another issue.The contactor gives the power to start the outside unit up.The time delay gives an interval for it to start...
  17. Replies
    3
    Views
    641

    I'd have called the installing company.You've...

    I'd have called the installing company.You've been using them for your regular maintenance and check-ups,haven't you? Please tell me you've had regular service performed on it.The oil you are seeing...
  18. Replies
    5
    Views
    934

    Register and take it to the "Pros Forum" and...

    Register and take it to the "Pros Forum" and ask.We can help you there.
  19. A HARD START KIT is used to boost the compressor...

    A HARD START KIT is used to boost the compressor on start up only.The time delay only controls how long it takes for the CONTACTOR to close and start the condensor fan motor and compressor when a...
  20. I'd stick with what you have and have metal duct...

    I'd stick with what you have and have metal duct installed.You'd be eliminating alot of flow resistance and saving a lot in the long run using the existing crawl.The heat gain in your crawl is quite...
  21. Replies
    16
    Views
    1,363

    68 feet? I would have done as Beenthere stated...

    68 feet? I would have done as Beenthere stated and gone with a new supply and added a return.
  22. Replies
    9
    Views
    824

    I personally wouldn't go this route.Mis-matching...

    I personally wouldn't go this route.Mis-matching the components is only asking for trouble.I also wouldn't waste my time with a 10 seer,especially going to a HP.If your going to install a new...
  23. Replies
    87
    Views
    4,846

    I'm starting to get the feeling he doesn't like...

    I'm starting to get the feeling he doesn't like "inflation".
    "if he had said $4000.00....sold.......16 years ago".Times have changed and prices have gone up.Get your bids and best of luck.
  24. Replies
    26
    Views
    2,197

    The main pan is full and causing the leak.Seal...

    The main pan is full and causing the leak.Seal the outside line as best you can to a shop vac and suck out the line.If this doesn't work, use a compressor(with a regulator) and blow air in to the...
  25. Replies
    14
    Views
    1,141

    Sorry.It's getting late and hadn't read it...

    Sorry.It's getting late and hadn't read it thruoghly enough.Please map out the N,E,S,W, on your map.I've got a good guess but would like to know more.