Search:

Type: Posts; User: BaldLoonie

Page 1 of 20 1 2 3 4

Search: Search took 0.21 seconds; generated 18 minute(s) ago.

  1. Those figures are to plug into a big long formula...

    Those figures are to plug into a big long formula based on utility rate and location. Still, doesn't make sense. I've never used those numbers.
  2. Sometimes it is easy to fish a new wire, other...

    Sometimes it is easy to fish a new wire, other times not. Something to ask. There are wireless stats you can get. Be nice for the Trane, with the Carrier you'd be 1/2 way to an Infinity control.
  3. The XV95 is not communicating. You use any 24v...

    The XV95 is not communicating. You use any 24v stat, again suggesting 2 stage. The Carrier can go either way. If you want to keep your current stat, just have the contractor do the advanced setup on...
  4. Replies
    17
    Views
    1,024

    The original unit was sitting at a 90 angle to...

    The original unit was sitting at a 90 angle to this one so it would have had plenty of clearance for air anyway. The back side a human might not have fit.
  5. The Infinity control will do so much more than a...

    The Infinity control will do so much more than a generic thermostat - not to mention the error messages that can be tracked.

    At least wire the stat to do the staging since the board won't allow a...
  6. Replies
    2
    Views
    92

    Some of the Honeywell Vision Pros and Prestige...

    Some of the Honeywell Vision Pros and Prestige models can do this.
  7. Replies
    8
    Views
    351

    There could be a minimum temp it goes to even if...

    There could be a minimum temp it goes to even if the thermostat can be set lower. That keeps the coils from freezing up. I'd expect it can do 68 though. And your 8 split sure is low.
  8. Replies
    13
    Views
    590

    Get a 2nd opinion if you don't trust them. We...

    Get a 2nd opinion if you don't trust them. We have a big competitor that techs like to tell customers their comp is shot when it is just the run capacitor keeping it from running.
  9. Replies
    3
    Views
    138

    Looks like Willie's condensing boiler is the...

    Looks like Willie's condensing boiler is the Weil-McLain GV. They apparently don't have a modcon.
  10. Replies
    20
    Views
    531

    The installed difference in price between an 80%...

    The installed difference in price between an 80% furnace and a 95% furnace can be paid back in gas savings in under 10 years in many cooler climates. The installed price of a mod con vs an 83% cast...
  11. Replies
    17
    Views
    1,024

    I don't get these idiots and their curb adapters....

    I don't get these idiots and their curb adapters. I bet there was a Trane there. Do they install another Trane? No, they put in that POS Carrier and the adapter turns it 90 and that's what they get....
  12. #1 doesn't make sense. His numbers call for...

    #1 doesn't make sense. His numbers call for 45,000 BTU, you've had a 60K all these years yet he proposes a grossly oversized Trane 80. What a maroon.

    Listen to tiger.
  13. Replies
    20
    Views
    531

    The national trainer for a leading brand told us...

    The national trainer for a leading brand told us in class if he were doing it and had baseboard, he'd go cast iron.

    Sure the gas bill will be a bit higher BUT the initial cost will be thousands...
  14. Trane's aluminum Spine Fin coil has been in use...

    Trane's aluminum Spine Fin coil has been in use for nearly 55 years and is proven virtually leak free. All manufacturers are switching to aluminum indoor coils to avoid leaks.

    At minimum get a...
  15. Replies
    13
    Views
    523

    Gravity? At a guess probably 60s at the latest....

    Gravity? At a guess probably 60s at the latest. Post a picture, I have a couple old Moncrief brochures, I can see if I see it in there.

    The Moncrief name is in the York family but they aren't...
  16. Replies
    9
    Views
    365

    Who doesn't? I haven't found one different from...

    Who doesn't? I haven't found one different from the rest. There were some oldies, probably 70s or older, that were reversed from today's standard.
  17. Replies
    7
    Views
    306

    Might as well have the installer do it and test...

    Might as well have the installer do it and test it. With Honeywell anyway, the warranty on contractor controls is 5 year, but 1 year for the similar product at the home store.

    For a lower priced...
  18. Yes

    Yes
  19. Nothing extra is required for DOD. I haven't...

    Nothing extra is required for DOD. I haven't worked up the effort to install my duct sensors yet :D

    Just need the right setting on the stat, right wiring at the furnace.
  20. Replies
    7
    Views
    306

    You'll need the lifetime heat exchanger warranty...

    You'll need the lifetime heat exchanger warranty on the Carrier. It's aluminized steel and especially if it's at all humid there - will rot out in 10 years. On the Trane, the heat exchanger is...
  21. Replies
    154
    Views
    5,259

    The humidifier terminals of the board of the...

    The humidifier terminals of the board of the R96VA are not like other furnaces. He needs to read the instructions carefully on how to wire the Prestige to control the humidifier and how to tie the...
  22. First, never fire the furnace with the service...

    First, never fire the furnace with the service panel off. Flames will roll out! Dangerous.

    Without being there with a meter, no idea why you have heat & cool at the same time.
  23. Replies
    14
    Views
    404

    Yes, that's a deluxe 10 SEER Heil or possibly...

    Yes, that's a deluxe 10 SEER Heil or possibly Arcoaire.
  24. The Prestige IAQ is not hard to work with. He...

    The Prestige IAQ is not hard to work with. He must not have sharp installers :D I can do it in my sleep or at least 1/2 asleep. Hooking up DOD requires 1 setting on the setup and about a minute of...
  25. Replies
    3
    Views
    240

    Trane is a much better built A/C than the other 2...

    Trane is a much better built A/C than the other 2 but despite it's "16 SEER" model name XR16, most matches are 14-15 SEER. The other 2 units with high efficiency blower motors and 13 SEER outdoor...