  1. Replies
    18
    Views
    1,432

    So this is your first sighting of this unit? Who...

    So this is your first sighting of this unit? Who was servicing it before you got tapped? I'm always suspicious of new accounts who drift into the line-up with museum vintage equipment. I somehow...
  2. I agree. A 34-year old unit is probably at best...

    I agree. A 34-year old unit is probably at best an 8.5-SEER unit and could easily be even lower than that. Even a 13-SEER system will improve the operational efficiency enough to make the 13-SEER...
  3. I think you're apt to find a lot of "cross...

    I think you're apt to find a lot of "cross pollination" of work these days. Many companies are recognizing their slow times of year and trying to compensate by introducing new services that others ...
  4. Replies
    15
    Views
    626

    You can quickly weed out those using short-cuts...

    You can quickly weed out those using short-cuts simply by observing or asking before hand if they're doing a ACCA Manual J-8 load calculation. If not, keep searching. In a vast majority of instances,...
  5. Replies
    12
    Views
    692

    The factory amount of charge is listed on the...

    The factory amount of charge is listed on the condenser data plate. That generally allows for 25-feet of refrigerant line and attachment to the smallest coil that would be a match for the condensing...
  6. Replies
    28
    Views
    1,430

    Yes, we've all been burned a time or two. Had a...

    Yes, we've all been burned a time or two. Had a president of a large local distributor ask me to install mini-splits in a friend's house. Did the load analysis, speced out the equipment, which was...
  7. Replies
    8
    Views
    529

    The first consideration I'd make would be where...

    The first consideration I'd make would be where the treated/non-treated barriers are located. For example, if you're using fiberglass bats as insulation located in the ceiling of the upper floor,...
  8. Hmmm. Not the type of situation that can be...

    Hmmm. Not the type of situation that can be diagnosed over the telephone. What I can state from far away is that there are two things leading to a frozen coil. First is low airflow and the second is...
  9. Replies
    2
    Views
    217

    Anything can be done for a price. Where the leak...

    Anything can be done for a price. Where the leak is located could be key to the wisdom of repairing or replacing. Is this the indoor coil or the outdoor coil? And BTB, there is no 4.5-Ton system....
  10. Replies
    16
    Views
    794

    You didn't include any information as to your...

    You didn't include any information as to your location. There are many factors that affect efficiency but chief among them is proper sizing of the equipment. A proper load analysis, followed by a...
  11. Replies
    23
    Views
    751

    Well first, we don't know in what fashion the TXV...

    Well first, we don't know in what fashion the TXV failed, or if it failed. Absent additional technical info, it's very difficult to provide specific answers. You state one of the copper lines (you...
  12. Replies
    10
    Views
    648

    Hmmm. Putting a little spin on your question,...

    Hmmm. Putting a little spin on your question, would buying the components for a new car on line and having a local auto mechanic build it make sense? I doubt you'll find a true pro on this site that...
  13. Replies
    9
    Views
    490

    The science in sizing involves load analysis that...

    The science in sizing involves load analysis that results in both greater comfort for the human being and better health for the equipment. However, the equipment ultimately installed could be...
  14. Replies
    1
    Views
    177

    I would not recommend a second humidifier on the...

    I would not recommend a second humidifier on the system. Too much by-pass air can have a very detrimental affect on the other components in the system. A better idea is to cut down on the air...
  15. Replies
    9
    Views
    663

    There are some issues here that need...

    There are some issues here that need clarification. Carrier/Bryant units had two entirely different compressors on their 16/18 SEER units. The 16-SEER requires the compressor to stop and restart to...
  16. IMO, the Greenspeed is best. There are two ways...

    IMO, the Greenspeed is best. There are two ways to size the equipment however. Option 1. is to size for the cooling load and enjoy superior dehumidification in summer due to the ramping down of the...
  17. Replies
    17
    Views
    3,437

    It wasn't the negative uneed to vent the unit so...

    It wasn't the negative uneed to vent the unit so much as the pipe heated up so quickly it allowed the minimal pressure of the 80% furnace inducer to do the job. Once the vent had to be replaced, it...
  18. Too late for the blower motor. Might as well...

    Too late for the blower motor. Might as well change the furnace. Won't take as long as putting that mess back together.
  19. Replies
    1
    Views
    1,118

    So why is there a carboard frame around that nice...

    So why is there a carboard frame around that nice warm blanket?
  20. Replies
    26
    Views
    2,721

    There's a lot more to it than we understand. For...

    There's a lot more to it than we understand. For example, a substantial number of on-linen sales are made right out the back door of distributors we all know and use. Only the names are changed to...
  21. It should be noted that mounting the units...

    It should be noted that mounting the units indoors does not guarantee against a frozen/split unit. During prolonged power outages, frigid air can and does make its way down the intake and exhaust...
  22. On what are you basing your complaint that you're...

    On what are you basing your complaint that you're using an unreasonable amount of fuel? Could it be that it's been colder than normal in your location, like most of the country? You can cut your bill...
  23. It's all too common for people to try and compare...

    It's all too common for people to try and compare fuel usage between years and even between homes. There are many variables at work that are unseen and overlooked. The only reasonable way to try and...
  24. You seem very willing to part with your money so...

    You seem very willing to part with your money so why not do it yourself and part with the control board too? Or alternatively, call a good company and let them do the work. The Big Box people would...
  25. Replies
    6
    Views
    483

    Your numbers are not totally correct but the...

    Your numbers are not totally correct but the differences are minor. In reality, you don't normally purchase natural gas in Cubic Feet but rather therms. CuFt is just what the meter records but...