  1. What was the heat and cool supply vent about? ...

    What was the heat and cool supply vent about? Was it a damper he was talking about? Or was he referring to closing supply vents?
  2. Replies
    9
    Views
    527

    Sorry correction, this is an LP setup. Had 6.58...

    Sorry correction, this is an LP setup. Had 6.58 iwc on low running 39960 btuh of 54000. After reading the manufacturers nomenclature i found this=
    Units fueled by LP/propane gas are rated for...
  3. Replies
    9
    Views
    527

    Outlet 1.83 iwc on low fire.

    Outlet 1.83 iwc on low fire.
  4. Replies
    14
    Views
    742

    Have the fluke combo. Only complaint was the...

    Have the fluke combo. Only complaint was the temp adapter stopped working. Really like the retractable leads.
  5. Replies
    7
    Views
    314

    This was one of two returns. It was an upstairs...

    This was one of two returns. It was an upstairs 12x12..... it was a 2 ton brand new cbx25uh. Had one of those 3M 16x25x1 static killer on the other return. I told her to visit filter easy website...
  6. Replies
    7
    Views
    314

    indoor air quality is always on the back burner.

    indoor air quality is always on the back burner.
  7. Replies
    7
    Views
    314

    Dirty filter contest?

    Temporary filter 12x12 circa 2005 :eek2:515691
    HO said nobody ever asked to check the filter upstairs.
  8. Replies
    9
    Views
    527

    Oh will do. Thinking if the high fire solenoid...

    Oh will do. Thinking if the high fire solenoid is energized but not working inducer will not ramp up either. Its a 15GCSX series btw
  9. Replies
    9
    Views
    527

    Was on the phone with lennox tech support, they...

    Was on the phone with lennox tech support, they quickly told me to replace the valve and they have seen this before. Of course I did check t-stat setup, wiring, and gas pressure.
  10. Replies
    9
    Views
    527

    No fuse. Call for hi fire, voltage present at...

    No fuse. Call for hi fire, voltage present at common and hi, but no high fire.
  11. Replies
    9
    Views
    527

    gas valve issue

    Had a routine maintenance call today on a brand new Lennox gas pack. 1st stage check. Wait wait wait. No second stage. Ok install did not set up t-stat properly.... nope. Short in valve. High...
  12. Replies
    16
    Views
    611

    I changed about 10 this season. Atleast the...

    I changed about 10 this season. Atleast the module is a quickie.
  13. Replies
    28
    Views
    1,523

    What exactly is Tjernlund? Have not heard that...

    What exactly is Tjernlund? Have not heard that before. Pretty sure my board is gone. Will go through fire sequence maybe 1 out of 7 tries.
  14. Replies
    10
    Views
    563

    Had a cracked HX today on a Nordyne pack. And a...

    Had a cracked HX today on a Nordyne pack. And a hour on the phone with a home warranty department. Elderly couple needed help speaking to an impatient adjuster.
  15. Replies
    18
    Views
    1,140

    Is it a high crime area? Hehe

    Is it a high crime area? Hehe
  16. Replies
    28
    Views
    1,523

    Error code... flame detected when no call.

    Error code... flame detected when no call.
  17. Replies
    28
    Views
    1,523

    The one in my garage is a XL80 two stage with an...

    The one in my garage is a XL80 two stage with an intellite board. Sometines goes through sequence, but it usually runs inducer and blower in low speed. Board.
  18. Replies
    24
    Views
    3,096

    Keep it hidden.

    Keep it hidden.
  19. Replies
    45
    Views
    2,749

    I just did my fall pm on my ge's. Went in the...

    I just did my fall pm on my ge's. Went in the crawl and found I have a steam humidifier going, or just a pin hole in some quest..... hot water.... real mess now. Gonna grab 2 blower fans tomorrow...
  20. Replies
    3
    Views
    613

    Flanges were cracked..... I recommended...

    Flanges were cracked..... I recommended replacement. The ho was not aware of the problem, so he says. Its a shame... looks like its been in a flood as well as a mouse house.
  21. Replies
    37
    Views
    1,403

    So long as its not addictive.

    So long as its not addictive.
  22. Replies
    37
    Views
    1,403

    Whats the best way to limit airflow restrictions...

    Whats the best way to limit airflow restrictions in a rolled bill? Cfm/nasal passage/restrictions I.e. hair not counted unless its a wet situation.
  23. Thread: CapSizing

    by Todd Whaley
    Replies
    23
    Views
    859

    I have done the three cap bomb before many times....

    I have done the three cap bomb before many times. Each gets their own metal bracket.
  24. Replies
    3
    Views
    613

    Loud inducer?

    514641

    A G51MP with an inducer running RLA. It's very noisy without the pvc..... :eek2:
  25. Replies
    9
    Views
    663

    Not changing out. It has already had a HX...

    Not changing out. It has already had a HX transplant a few years back. The Evap is leaking. The HO will probably wait till spring to replace the unit.