Search:

Type: Posts; User: saylor240

Page 1 of 20 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    213

    i got the samsung french door top and freezer...

    i got the samsung french door top and freezer bottom from lowes about a year ago, got the extended warranty from lowes.
    Unit great so far, you can set fridge and freeze temps, have dual cooling. we...
  2. Well tiger loop makes them, its required for a...

    Well tiger loop makes them, its required for a single pipe system. you do have to consider tank location. is the oil heater above or below the oil tank? when was the last time the tank was drained...
  3. Replies
    11
    Views
    399

    really should not be a problem, just buy one from...

    really should not be a problem, just buy one from a big box store that has a good return policy, then if it fails just bring it back...
  4. Thread: Goodman

    by saylor240
    Replies
    8
    Views
    377

    what is amp draw of the motor? this really...

    what is amp draw of the motor?
    this really first time you have seen a sequencer used for fan operation?
    Does the unit have electric heat?
    Does the unit only freeze when the fan is not running?
  5. there is a lot more than just capping off, Tank...

    there is a lot more than just capping off, Tank location, and if you worked on oil 30 plus you would know you would need a "device" installed to make it a one pipe.
  6. :grin2:

    :grin2:
  7. you can make it last longer by setting your...

    you can make it last longer by setting your thermostat at 78 instead of 72...I am guessing you have set at 72 due to your return temp. if you could set higher you could reduce energy bills and make...
  8. had issues with Trane coils years ago, was the...

    had issues with Trane coils years ago, was the coating on the coils...ask how much to change the indoor evap coil with new..
  9. Has any of the 3 done a proper load calculation? ...

    Has any of the 3 done a proper load calculation? Who ever you go with have everything in writing of what they are promising, so in the event you have issues in the future you have paperwork to back...
  10. Replies
    29
    Views
    797

    try and pump it down...

    try and pump it down...
  11. Replies
    7
    Views
    249

    I would like to know where they get 16 seer out...

    I would like to know where they get 16 seer out of that..
  12. Replies
    9
    Views
    1,668

    looks like it just needs new paint///

    looks like it just needs new paint///
  13. Replies
    3
    Views
    294

    no way he got in thru the PVC vent as it is a...

    no way he got in thru the PVC vent as it is a sealed burner chamber that does not allow flue gas to mix with your air return, yes the unit could have a bypass if it is a zone system it would be off...
  14. Replies
    51
    Views
    2,325

    New techs have it easy these days anyway, all the...

    New techs have it easy these days anyway, all the caps I see at the supply house say 370/or 440 and they have Turbo caps available.....Oh how i could have used some turbo caps 20 years ago on a...
  15. Replies
    31
    Views
    1,850

    Just a thought....have the Airflow been checked?

    Just a thought....have the Airflow been checked?
  16. Replies
    15
    Views
    702

    sparks could fly and board meltdown if it board...

    sparks could fly and board meltdown if it board failed and called for low/high motor speed at same time?...
  17. Replies
    16
    Views
    1,048

    i would get hoses with manual shut off 1/4 turn...

    i would get hoses with manual shut off 1/4 turn valves, almost no failure rate on those.
  18. Replies
    12
    Views
    300

    Access to a breaker panel should never be...

    Access to a breaker panel should never be block/restricted what if Muffy the cat chewed on electrical cord and was being shocked would you rather grab the cat or just shut off the breaker..
  19. Replies
    15
    Views
    702

    Me personally I would call my local Carrier rep...

    Me personally I would call my local Carrier rep (if its them call the next closest) and ask them if they do free second opinions. It sounds like you have a electrical issue to destroy a board like...
  20. Replies
    19
    Views
    799

    Now that makes sense thanks for the Info...learn...

    Now that makes sense thanks for the Info...learn something new every day
  21. Replies
    31
    Views
    1,850

    :LOL:

    :LOL:
  22. Replies
    31
    Views
    1,850

    If unit is freezing randomly could contamination...

    If unit is freezing randomly could contamination of moisture in Gas or unit was charged with gas and not liquid cause the azeotropic blend to break down?
  23. Replies
    51
    Views
    2,325

    In series or parallel?

    In series or parallel?
  24. Replies
    19
    Views
    799

    410A service cores do have different color, cause...

    410A service cores do have different color, cause of higher pressure, but i don't think there is a industry standard yet on the color...but i could be wrong....But i have installed a "regular" core...
  25. Replies
    15
    Views
    455

    sounds like something has failed and overheated...

    sounds like something has failed and overheated and to continue to run it will only cause more harm and damage. A tech service company should be able to diagnose in less than 1/2 hour service call.
Results 1 to 25 of 493
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event