Search:

Type: Posts; User: Joelfu27

Search: Search took 0.00 seconds.

  1. Replies
    8
    Views
    835

    It is better to remain silent and look a fool...

    It is better to remain silent and look a fool than to open your mouth and remove all doubt.
  2. Replies
    8
    Views
    835

    It is probably a cooling tower.

    It is probably a cooling tower.
  3. Replies
    3
    Views
    1,593

    how much?

    how much?
  4. Replies
    1
    Views
    558

    Cooper 3 prong thermometer.

    Just like new used maybe 10 times. I'm lookintg for 125 for it,. They go for 225 band new.



    http://www.hvacr-tools.com/product_photos/571-1-display.jpg


    Call ME AT 954-665-4678
    MY NAME IS...
  5. Replies
    8
    Views
    1,044

    The water lines in the heat pump are 1/2". Now...

    The water lines in the heat pump are 1/2". Now the loop lines to the unit are 3/4". The lines reduce to 1/2" after the shutoffs. Now we have had problems with some of our ice machines that use 404a...
  6. Replies
    8
    Views
    1,044

    Missing info.....

    Cooling
    water inlet temp: 72F outlet: 148F
    low: 135psi High 525psi
    suction line temp 71.7f

    Heating
    water inlet temp: 72f outlet 29.8f

    unit cuts out before a reading can be...
  7. Replies
    8
    Views
    1,044

    Problem W/ Carrier Water Cooled Heat Pump

    I work at a hotel that uses mostly R22 Macquay Heat pumps in the rooms and any other space. The hotel is 8 years old and a few of the compressors have failed. The owner had the first 1/2 ton room...
  8. Replies
    14
    Views
    2,244

    Charging 404a liquid through low side?

    I am working on an ice machine and need to charge a few ounces of 404a to see if my low pressure problem is from a low charge or if the problem is the txv starving the compressor.
    Do I need to...
  9. Replies
    4
    Views
    1,894

    Thanks, I may have someone bringing me a drag...

    Thanks, I may have someone bringing me a drag line socket, if he can find it.
    I have a replacement sight glass and gaskets coming in today too.
    Thanks for the tip
  10. Replies
    4
    Views
    1,894

    Removal of Copeland compressor sight glass

    Does anyone know an easy way to remove the sight glass from a compressor?
    I know there are sight glass removal socket pieces, but I'm trying to get this done today and without damaging the sight...
Results 1 to 10 of 10
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event