  1. Replies
    37
    Views
    4,077

    Remember It only acts up during the afternoon, in...

    Remember It only acts up during the afternoon, in the morning and eairly afternoon pressures amp draws and sc/sh is normal, so the airflow restriction would make sense but I'm just not seeing it
  2. Replies
    37
    Views
    4,077

    Both *factory driers*

    Both *factory driers*
  3. Replies
    37
    Views
    4,077

    I removed both driers in the heat pump and put in...

    I removed both driers in the heat pump and put in a biflow drier, I've washed the coil several times, no restriction in airflow around heat pump, fan motor is good its pulling out air, amp draw...
  4. Replies
    37
    Views
    4,077

    havent been on here in a week or so i was on-call...

    havent been on here in a week or so i was on-call and busy busy. So this customer got back into town,today i replaced the txv, the drier, charged all new refrigerant. the system symptoms are the same...
  5. Replies
    24
    Views
    3,003

    Who's Russell? I'm kinda new on here still

    Who's Russell? I'm kinda new on here still
  6. Replies
    18
    Views
    1,677

    I actually have seen that once on a system but I...

    I actually have seen that once on a system but I pulled about 12lbs out of it and had a heart to heart talk with the installer lol... But does sound like inaccurate readings.
  7. Replies
    24
    Views
    3,003

    Yeah I called them no such luck left a message...

    Yeah I called them no such luck left a message but who knows if theyll call back ill go on their website and see what to do
  8. Replies
    24
    Views
    3,003

    Not much it just looks cool haha...this is My...

    Not much it just looks cool haha...this is My first set with a sight glass on it, actually my first set of digital gauges ever, but all I could tell is between liquid and vapor going in the system...
  9. Replies
    37
    Views
    4,077

    It's a matched size wise I did check on that,...

    It's a matched size wise I did check on that, yeah boss man said replace txv so that's what I'm doing next week, we'll see how it goes... I personally have a hard time saying its the valve according...
  10. Replies
    24
    Views
    3,003

    Awesome! I'll do that this weekend, hope they...

    Awesome! I'll do that this weekend, hope they improve on the manifold part
  11. Replies
    24
    Views
    3,003

    Fieldpiece SMAN3

    Was curious if anyone else has or knows a little about these gauges, I bought them a little over a month ago and spent a pretty penny getting them, I really enjoy using them and having a Micron...
  12. Replies
    37
    Views
    4,077

    Yup in the morning the system is fine and...

    Yup in the morning the system is fine and operating normally, im within my refrigerant curve but it gets all wonkified (technical term) in the afternoon lol
  13. Replies
    37
    Views
    4,077

    Fan motor on particular unit isn't var. Speed or...

    Fan motor on particular unit isn't var. Speed or multi-speed, amp draw normal.. motor working within specs. The boss man says replace txv so I'm gonna do what I'm told, the customers out of town so...
  14. Replies
    37
    Views
    4,077

    besides my dc voltage from rectifier im not sure...

    besides my dc voltage from rectifier im not sure how to check if the compressor is open all the way
  15. Replies
    37
    Views
    4,077

    line set only 25 feet not long at all i took...

    line set only 25 feet not long at all i took readings everywhere lol, common suction, after reversing valve and suction in at airhandler. for my subcooling before and after dryer in unit and outside...
  16. Replies
    37
    Views
    4,077

    condensor coil clean as a whistle, no airflow...

    condensor coil clean as a whistle, no airflow restrictions what so ever, i changed the speeds on my indoor motor several time to see any change.. none that would make a huge difference... i have a...
  17. Replies
    37
    Views
    4,077

    that is a issue a big issue but according to the...

    that is a issue a big issue but according to the customer it was fine a week ago.. try telling him he needs new duct work, the unit has wall chases i have a 6 degree difference from vent to plenum...
  18. Replies
    37
    Views
    4,077

    checked the dryer is not clogged, checked fan...

    checked the dryer is not clogged, checked fan motor okay during all of this running like a camp lol 4 years old
  19. Replies
    37
    Views
    4,077

    i thought that to maybe it being non-combustables...

    i thought that to maybe it being non-combustables but my superheat and subcool are regulated too well in my opinion to be non-combustables. the issue also happened all the sudden too... not stupid...
  20. Replies
    18
    Views
    1,934

    what is the starting amp on the compressor ,...

    what is the starting amp on the compressor , might need to add start kit if not i would suggest checking resistance in compressor windings might be weak
  21. Replies
    37
    Views
    4,077

    a problem unit

    hello fellow techs i have a a/c system that has stumped me and would like to see what everyone else thinks. call: not cooling good in afternoon.
    I have a 4 year old 4 ton trane 16seer 410-a heat...