  1. Would I be able to make it through the winter if...

    Would I be able to make it through the winter if I just had the Fill-Trol valve and Pressure relief valved replaced until then?
  2. Maybe the removable screen on the Fill-Trol (auto...

    Maybe the removable screen on the Fill-Trol (auto pressure reducer / fill) valve is clogged?
  3. The air scoop on top of the auto pressure...

    The air scoop on top of the auto pressure reduction/fill valve also seems to be hollow.

    The furnace has been turned off for around 27 hours.
  4. So after tinging around on the pipes, I can hear...

    So after tinging around on the pipes, I can hear that they seem to have NO water at all in them. The expansion tank has a ting at the bottom and a thud at the top, similar to the mainline pipe.
  5. Both Schrader valves can be depressed freely now,...

    Both Schrader valves can be depressed freely now, but nothing exits the valve- no water or air - they just move up and down freely as if not even installed, even with the supply valve open.
  6. Not totally sure if the pump needs replacing, the...

    Not totally sure if the pump needs replacing, the second video I posted was just the noise of the pump (I kept the camera cap on the lense).

    I am aware that the auto fill/pressure reduction valve...
  7. So From what I can tell, about 6 parts need to be...

    So From what I can tell, about 6 parts need to be replaced. 2 auto-air purgers (I found one that was corroded in the upstairs radiator that had the cap on so tight i had to use pliers to take it off,...
  8. Thank you :yes:

    Thank you :yes:
  9. It's okay lol, I've worked on computers for the...

    It's okay lol, I've worked on computers for the last 10 years and those are kind of my specialty. I like to work on tips - I know everyone can't afford it.

    It does make sense though about the...
  10. Anyone have a clue on how much this might all...

    Anyone have a clue on how much this might all cost? :-/ I suspect a lot..
  11. i recharged the expansion tank to 12psi, no...

    i recharged the expansion tank to 12psi, no change in the boiler pressure meter, its still at 0psi. Still no water flow from the supply line either.. im guessing its stuck closed as suggested, i...
  12. we actually turned everything but the pilot light...

    we actually turned everything but the pilot light off yesterday morning :yes:
  13. The expansion tank is this one...

    The expansion tank is this one http://ecomfort.com/fill-trol-110-expansion-tank-fill-valve-44-gallon-110-1-3093.html . When I measure the tank it reads at less than 5 psi, when I first checked it - a...
  14. With the water supply valve open all of the way,...

    With the water supply valve open all of the way, the Flow Rate on the Water meter reads ".000" I found out that the leak showing up on the meter was from the basement toilet reservoir.

    How hard...
  15. The part that you speak of has the other side...

    The part that you speak of has the other side fully bolted in. I just thought the part was ambidextrous.
  16. About the American Auto Air Purger, the manual...

    About the American Auto Air Purger, the manual says it should be 14-18" from a bend? Am I understanding that correctly? If so, I don't think ours was installed correctly, as it's connected to the...
  17. Thank you for the advice, I'll make sure they do...

    Thank you for the advice, I'll make sure they do it the right way! :yes: Hope it doesn't have to be replaced though, it seemed to function normally when I turned it. With everything else though lol...
  18. The plastic buckets were actually just hedging my...

    The plastic buckets were actually just hedging my bets incase of a leak. I did have a bit of water escape from the auto-air purger but only a small amount.

    There actually is no automatic water...
  19. i read the rules and realize that and thank you...

    i read the rules and realize that and thank you for just responding at all :D lol i was just really wondering what maybe could be happening, or what the problem could be. but like you said, im sure...
  20. the pressure gauge on the boiler does usually...

    the pressure gauge on the boiler does usually work, you can see it at 2:51 in the video. it goes up to 3-4 when the boiler is heating the water, then drops down after. the water is heated, but doesnt...
  21. Forced hot water boiler no pressure question, Why do i have no water pressure in my b

    http://www.youtube.com/watch?v=XG29vzV0314

    a link with a video of the problem, the taco pump is a 007-870, the psi in the expansion tank is <5. the models of zone valves are 1311-102 and 1361-102....