Search:

Type: Posts; User: GREGHVACGUY

Page 1 of 10 1 2 3 4

Search: Search took 0.01 seconds.

  1. I have a few ? Have you had it clean/tune up on...

    I have a few ? Have you had it clean/tune up on it in the last 1.5 years? Would you drive your car for 1.5 years with out having the oil change or check the air in your tire?
    Your furnace/ac run....
  2. Replies
    2
    Views
    72

    I will be there Wednesday.

    I will be there Wednesday.
  3. I will bet there will be someone on here in the...

    I will bet there will be someone on here in the next few day that will have there flue cover in snow.
  4. does anyone know of anyone contractor getting...

    does anyone know of anyone contractor getting checked out by the EPA or getting a fine?
    back in the 90s they would stop in and check all your paper trail.
  5. Replies
    5
    Views
    248

    So is captiveaire trying to do there work in...

    So is captiveaire trying to do there work in house and not use out side contractor?
  6. Thread: On call

    by GREGHVACGUY
    Replies
    9
    Views
    315

    I think he slid off roof. hope your ok. I will...

    I think he slid off roof. hope your ok. I will not go on roof if it has snow or frost.
  7. Replies
    12
    Views
    522

    I would say get him a heated jacket. Milwaukee ...

    I would say get him a heated jacket. Milwaukee and dewalt make them. if your not sure witch cordless tool he use milwaukee are red dewalt yellow. also vote on... put on something from Victoria...
  8. Replies
    6
    Views
    344

    wifi thermostat use the wifi they have in the...

    wifi thermostat use the wifi they have in the house or building. there is two way to wire it you can drop the g and jump it at furnace to the y so you can use the g wire for you com.( t-stat will not...
  9. Replies
    11
    Views
    343

    Im thinking the ignitor you have is not right. I...

    Im thinking the ignitor you have is not right. I dont know that trane use a hsi with metal around it. I would say ING00054 to. I would put in a glow fly.
  10. Replies
    29
    Views
    1,164

    I would use the honeywell IAQ's the thermostat is...

    I would use the honeywell IAQ's the thermostat is just the control then you put the control base (relay) at the furnace. Only needs 3 wires This way he can control his furnace at the bedroom. yes...
  11. Just thinking here. moving hot are over the ac...

    Just thinking here. moving hot are over the ac coil anyone think it could making the freon move making the coil cold. I know he has said the ac is off. I have seen this before that the freon would...
  12. Have you paid him for the install? If not have a...

    Have you paid him for the install? If not have a new company put one info you. I used to work for a guy that did this same thing. even put scratch and dent in and would not tell the home owner.
  13. Replies
    5
    Views
    296

    Thanks for your service. good luck with job.

    Thanks for your service. good luck with job.
  14. I would say yes there is something going on with...

    I would say yes there is something going on with the ahu. may be to small. not sure what btu that coil give off. may be moving air to fast so its not picking up the heat off the water.
  15. that relief valve need to be pipe to the floor...

    that relief valve need to be pipe to the floor before someone gets hurt. stop using the fire place till you get it looked at. and post back what they find thanks.
  16. The service guy can plug into the board with his...

    The service guy can plug into the board with his laptop or smart phone and read that board. and do any update to it. I think there is a update to the software that fixed the store codes.
  17. Replies
    6
    Views
    256

    (you will have access to the brightest minds in...

    (you will have access to the brightest minds in the business) Now you are talking everyone up on this site. We will have to are A game on.:cheers: rundawg is right get ti 15 and you will find your...
  18. 541241541251541261 Just like this one Sent...

    541241541251541261
    Just like this one


    Sent from me to you using Tapatalk
  19. Thread: help?

    by GREGHVACGUY
    Replies
    19
    Views
    667

    Your Hvac contractor will have all of it and...

    Your Hvac contractor will have all of it and would love to put it all in for you and make sure it all works right.
    That unit needs to be set up right or it l will fail when its needed most. that...
  20. Replies
    20
    Views
    608

    Looks to me that the drain line clogged and...

    Looks to me that the drain line clogged and backed up into the a/c coil. leaking down into furnace.may have shorted out blower motor or other controls.I like to see drain ran by them self or set up...
  21. Replies
    71
    Views
    2,465

    Someone stole the lower 1/2 of the ladder.

    Someone stole the lower 1/2 of the ladder.
  22. Replies
    1
    Views
    230

    I can do the same thing with a tank of co2

    I can do the same thing with a tank of co2
  23. Replies
    22
    Views
    811

    found old post. I forgot I started it ....

    found old post. I forgot I started it .
    http://hvac-talk.com/vbb/showthread.php?1213531
  24. Replies
    22
    Views
    811

    You are seeing the same display as I have seen....

    You are seeing the same display as I have seen. there is a post on here about this same thing before.
  25. Replies
    23
    Views
    534

    If the breaker trips when power is turn on it may...

    If the breaker trips when power is turn on it may be something else shorted that is tripping breaker. I would look over everything before doing compressor.
  26. Replies
    64
    Views
    2,510

    I will have ti try the crayon trick. now I know...

    I will have ti try the crayon trick. now I know where to get rid of all the 1/2 used crayon left over from school. Could you tell me what color works best.:angel:
  27. Replies
    21
    Views
    1,384

    try and turn your fan all the time. if that fix...

    try and turn your fan all the time. if that fix it tell then when fan is on all the time it worked that should tell them something.
  28. Replies
    20
    Views
    1,219

    Pull trap and make sure there is nothing in it.I...

    Pull trap and make sure there is nothing in it.I remember the slp had problem with a wire nut getting stuck in the trap from shipping.
    also if the trap was screw to the furnace with a drill it would...
  29. Replies
    14
    Views
    1,121

    Just come south. you can have obomacare :gah:...

    Just come south. you can have obomacare :gah: there are alot of state that are in need of good tech. I live in chicago IL and every time I stop in a supply house there is someone there saying they...
  30. Replies
    20
    Views
    1,388

    On all the prv I have seen it say not to leave...

    On all the prv I have seen it say not to leave open. they are not mean of low water safety. they are there so its a one main fill and purge air. The unit should have a low water cut off safety. Not...
  31. Replies
    19
    Views
    1,002

    I would start by cleaning flame sensor,burner and...

    I would start by cleaning flame sensor,burner and the grounds.
  32. Thread: Bluetooth

    by GREGHVACGUY
    Replies
    14
    Views
    674

    I have the bose and love it. Also the bobby from...

    I have the bose and love it. Also the bobby from lizard lick towing if you watch the show.
  33. Replies
    5
    Views
    421

    make sure the drain is trapped and full of water....

    make sure the drain is trapped and full of water. Had a co worker change a inducer pressure switch and it still do the something when he called me for help. He was so mad when I poured a cup of water...
  34. Replies
    23
    Views
    1,145

    I would check the heat exchanger as if it has a...

    I would check the heat exchanger as if it has a crack it could be sucking the pilot flame away from the flame rod. also check your incoming gas pressure with furnace off them as it light the pilot...
  35. Replies
    2
    Views
    280

    What do you mean about copeland problem? I have...

    What do you mean about copeland problem? I have not heard?
  36. Thread: Puzzled

    by GREGHVACGUY
    Replies
    22
    Views
    1,556

    410 on a 22 coil? Im thinking unit is kicking out...

    410 on a 22 coil? Im thinking unit is kicking out more than she knows. She is just notes it in the after noon because its hotter out and the temp is going up in the house.
  37. Replies
    1
    Views
    274

    I think applo now is state. it has heating taps...

    I think applo now is state. it has heating taps put it goes into tank and use the same water as the hole tsnk.
  38. Replies
    18
    Views
    1,706

    That furnace has #5 on it need to find the other 4

    That furnace has #5 on it need to find the other 4
  39. Replies
    28
    Views
    1,698

    You said black soot around vents. Are you sure...

    You said black soot around vents. Are you sure its from a bad furnace not from candelas being burt in the house.
  40. the honywell vision pro you can set max setting...

    the honywell vision pro you can set max setting so you can set the ac to only go to 74 and no lower. you also can have it email you if the temp in house gets to hi or to low. then you can go online...
  41. Replies
    37
    Views
    2,168

    I would have waited to you got up there and took...

    I would have waited to you got up there and took my ladder and put back on my truck.
  42. Replies
    28
    Views
    1,662

    I will sell you one just tell me what you need....

    I will sell you one just tell me what you need. give a full load calculation of you home. dont forget duct lost, blower door test.then you can drive over and pick it up.
  43. Replies
    6
    Views
    353

    new drier.

    new drier.
  44. Thread: Tool bag

    by GREGHVACGUY
    Replies
    11
    Views
    1,086

    I have the lc and the hvac lc both good. I would...

    I have the lc and the hvac lc both good. I would go with the hvac lc bag one side has bigger pocket for meter
  45. Replies
    22
    Views
    1,838

    Stand on the street and if the house fits in this...

    Stand on the street and if the house fits in this open on paper it a 2 ton.
  46. Replies
    63
    Views
    3,263

    I have one set for 22,410,404,134,409,509....

    I have one set for 22,410,404,134,409,509. pressure is all the same just have to us a chart to get temp.
    The little oil will not hurt anything.
  47. Replies
    24
    Views
    1,056

    john you must be close to me. I have been to the...

    john you must be close to me. I have been to the same place I wounder if they ever got the humidity under control as it is a inside track with dirt. All this talk makes me what to pull the cars out.
  48. Thread: Bluetooth?

    by GREGHVACGUY
    Replies
    5
    Views
    641

    I use a bose. I love it. cost was 140.00 High but...

    I use a bose. I love it. cost was 140.00 High but its good.
  49. Replies
    62
    Views
    20,787

    Sticky: Poll: Other- Truck drive since 1/2 my day is in my...

    Other- Truck drive since 1/2 my day is in my truck driving.
  50. Replies
    37
    Views
    17,704

    Sticky: Poll: Just seen it show up on top of the page. so I...

    Just seen it show up on top of the page. so I just voted.
Results 1 to 50 of 497
Page 1 of 10 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event