Search:

Type: Posts; User: gazoo

Page 1 of 11 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    0
    Views
    117

    Lynxspring CSI driver

    anyone ever work with this AX/CSI driver?
  2. Thread: Distech RDIO

    by gazoo
    Replies
    5
    Views
    363

    "RDIO product or the IO-485 NRIO products...

    "RDIO product or the IO-485 NRIO products ".....is there a difference?
  3. Thread: Distech RDIO

    by gazoo
    Replies
    5
    Views
    363

    Does Distech have rdio(not ndio) or is this only...

    Does Distech have rdio(not ndio) or is this only for vykon? I can only find info for vykon used with rdio..
  4. Replies
    3
    Views
    237

    So I tried saving backup with datamate but I...

    So I tried saving backup with datamate but I could not connect... Would you know the process to connect to an mbc and save a backup?
  5. Replies
    3
    Views
    237

    Siemens System 600 Backup

    can you make a backup of network via WCIS?
  6. Thread: Distech RDIO

    by gazoo
    Replies
    5
    Views
    363

    Distech RDIO

    Anyone have experience dealing with this I/O for a JACE bos 6?
  7. Replies
    1
    Views
    230

    Distech Ax Question

    i created a proxy boolean point in ax that represents one of the bits in a "SVNT_state_Mux". problem is that it comes in as stale. any ideas out there why this is happening?
  8. Replies
    15
    Views
    913

    [QUOTE=raindow;19607461]@gazoo Yes, the system...

    [QUOTE=raindow;19607461]@gazoo
    Yes, the system had installed, now I want to add room pressure monitor for each room and 1 Bacview for system (Not PC with BMS software). I read about distech product...
  9. Thread: Ax Backup Error

    by gazoo
    Replies
    2
    Views
    129

    When I right click and try to backup station.......

    When I right click and try to backup station.... Right click and save station works fine tho...
  10. Thread: Ax Backup Error

    by gazoo
    Replies
    2
    Views
    129

    Ax Backup Error

    i am trying to backup my station but i get an error of "File path is out of scope: C/Niagara?EC-NET-AX-3.7.106/backups_xxxx

    dont know what i am doing wrong...
  11. Replies
    15
    Views
    913

    is the system already installed or do you have...

    is the system already installed or do you have them just out of the boxes?
  12. Thread: StruxureWare

    by gazoo
    Replies
    12
    Views
    686

    say you had one building that had siemens...

    say you had one building that had siemens controls. could you connect with SW?
  13. Thread: StruxureWare

    by gazoo
    Replies
    12
    Views
    686

    StruxureWare

    how is the physical set up for this TAC system set up? i keep hearing about "servers" of some sort. do they take the place of control routers? if so, in LON, do i need one for every FT-10 channel?...
  14. Thread: Circon Ax Issues

    by gazoo
    Replies
    0
    Views
    151

    Circon Ax Issues

    i am try to discover an Circon UHC300m07 controller in Ax. I have discovered the controller and then discover the points within the controller. the problem i have is i have several humidity points...
  15. Replies
    2
    Views
    228

    Ax Bql Exp Component

    i am trying to fill in the expression part of a bql expression component. I keep getting the following error..."javax.baja.sys.TypeException: out1 is type query:Null, but property is type...
  16. Thread: Siemens Alarms

    by gazoo
    Replies
    1
    Views
    168

    Siemens Alarms

    I have a point that has blue associated with "normal" and green associated with "proofing" in the alarm status consule. the problem i have is that some points stay in proofing color green even thou...
  17. Thread: ax px ?

    by gazoo
    Replies
    2
    Views
    221

    ok. thanks.

    ok. thanks.
  18. Thread: ax px ?

    by gazoo
    Replies
    2
    Views
    221

    ax px ?

    what is the difference between value binding, and bound label binding in a bound label?
  19. Replies
    1
    Views
    181

    Ax Service Connect Issues

    i have ax 3.7.106 on my laptop. i am trying to open the services folder on a jace with ax 3.6.406.1 but i get an error saying i need the module "webHMI". how do i get this module? it is not in my...
  20. Thread: AX Histories

    by gazoo
    Replies
    2
    Views
    312

    thanks

    thanks
  21. Thread: AX Histories

    by gazoo
    Replies
    2
    Views
    312

    AX Histories

    on one of my collection tables. in the trend flags column one of the rows has a start in between the italics. any one have an idea why? others are just italics. all rows say ok in status....
  22. Replies
    7
    Views
    520

    thanks guys for all the help....

    thanks guys for all the help....
  23. Replies
    7
    Views
    520

    i am trying to adjust in global commander. it...

    i am trying to adjust in global commander. it is a 6 inch duct. how would i find the limit for size box?
  24. Replies
    29
    Views
    3,546

    Can I get a copy please

    Can I get a copy please
  25. Replies
    7
    Views
    520

    Siemens Fault Code?

    i am trying to change cooling CFM max on a TEC. The commander is giving an error of FLN:Value out of range. Fault:0005. anyone see this before?
  26. Replies
    13
    Views
    2,702

    in the johnson controls vav box info sheet. what...

    in the johnson controls vav box info sheet. what is the smaller K factor number represent?
  27. Replies
    1
    Views
    281

    Ax Web Page Question

    i am trying to change schedules in the niagara network of field jaces after logging into web page of jace supervisor. Why do i keep having to log into the field changes every once in a while? ...
  28. Thread: Ax KitPxGraphics

    by gazoo
    Replies
    2
    Views
    311

    Ax KitPxGraphics

    i drag boiler and chiller images from tree to pane to create widget but i do not see images. any ideas?
  29. Thread: Niagara AX?

    by gazoo
    Replies
    2
    Views
    313

    thanks

    thanks
  30. Replies
    9
    Views
    619

    doesnet send out report. you can paste in ord...

    doesnet send out report. you can paste in ord area but wont send out.
  31. Thread: Niagara AX?

    by gazoo
    Replies
    2
    Views
    313

    Niagara AX?

    what is the difference between copy and copy special when copying a folder?
  32. Replies
    9
    Views
    619

    you cant export the series transform table in a...

    you cant export the series transform table in a report...i tried many a time.....had to buy separate software for that.
  33. Replies
    2
    Views
    382

    Network Service Tool V

    anyone have a manual for this software. How to connect, configure, etc...
  34. Replies
    2
    Views
    225

    Thanks mucho

    Thanks mucho
  35. Replies
    2
    Views
    225

    Ax Weatherservice Link

    how would i link the "State" slot from current weather in the weather report to a enum control point?
  36. Replies
    29
    Views
    3,546

    Can I get a copy please...

    Can I get a copy please...
  37. Replies
    9
    Views
    505

    why would suction go up if you are not...

    why would suction go up if you are not compressing as much gas anymore? i was thinking suction would go down and discharge would go down. condensor fans staying the same.
  38. Replies
    9
    Views
    505

    Unloader pressures

    when a compressor is unloaded, what should happen to the suction pressure and discharge pressure? up, down, nothing etc.
  39. Replies
    2
    Views
    263

    Siemens Connection Failure

    I am right clicking and pressing "connect or Dial" on my pxcm in the system profile and i keep getting the error:

    Remote BLN is already in the process of connecting
    Subsystem : ADAPT Identifier...
  40. Replies
    17
    Views
    1,794

    could you shoot me that info also please?

    could you shoot me that info also please?
  41. Replies
    8
    Views
    764

    My profile has my email.

    My profile has my email.
  42. What would be the reason to change this parameter?

    What would be the reason to change this parameter?
  43. Replies
    8
    Views
    764

    What do u mean by gator pit?

    What do u mean by gator pit?
  44. Replies
    8
    Views
    764

    thanks. this would help greatly. could you email...

    thanks. this would help greatly. could you email it to me?
  45. Thread: Siemens TX IO ?

    by gazoo
    Replies
    3
    Views
    245

    the point will close when commanded thru insight....

    the point will close when commanded thru insight. but manual override does nothing
  46. Thread: Siemens TX IO ?

    by gazoo
    Replies
    3
    Views
    245

    Siemens TX IO ?

    i have a TXM1.6RL module. I pressed the override button yellow light comes on but physical point does not close. any ideas? is the override function locked out?
  47. Replies
    1
    Views
    345

    Lochnivar Enable/Disable ?

    I have a Lochnivar Model:CHN0992 boiler. I am trying to find the enable/disable point on the board. I am used to raypak having one. this lets me control the ability of the boiler to heat. Not...
  48. Thread: Siemens TEC ?

    by gazoo
    Replies
    3
    Views
    281

    I am changing via global commander in insight. ...

    I am changing via global commander in insight. How do I know which version of app? what do you mean by "raw value"changing?
  49. Thread: Siemens TEC ?

    by gazoo
    Replies
    3
    Views
    281

    Siemens TEC ?

    I have a 2023 application on my tec. I keep changing point 32 "CLG FLOW MAX" but the point will not change. Point 77 shows the change but this point does not. any ideas out there?
  50. Replies
    8
    Views
    578

    is this only for bacnet? if not where do I find...

    is this only for bacnet? if not where do I find info on this "weather service broadcast"?
Results 1 to 50 of 546
Page 1 of 11 1 2 3 4
Comfortech Show Promo Image