  3. Thread: vav help

    by kontrolphreak
    Replies
    6
    Views
    385

    You can buy an over-the-counter VAV controller...

    You can buy an over-the-counter VAV controller from http://www.bacnetcontrol.com/shop/. This one here: http://www.bacnetcontrol.com/shop/hvac-controls/10-vav-controller-relay.html. Config software is...
  4. Replies
    33
    Views
    5,553

    Never mind. kontrol out

    Never mind.

    kontrol out
  5. Replies
    8
    Views
    581

    Please don't post your emails in any thread as it...

    Please don't post your emails in any thread as it is against site rules.

    kontrol out
  6. Replies
    16
    Views
    750

    Cylon buys AAM

    http://controltrends.org/2014/07/cylon-energy-inc-acquires-american-auto-matrix/

    kontrol out
  7. Replies
    3
    Views
    463

    If OAT is greater then 60degF and valid or...

    If OAT is greater then 60degF and valid or operator allows cooling when OAT is invalid and the follow (calculated in other parts of the program):
    System needs cooling.
    Economizer is in cooling....
  8. Replies
    7
    Views
    294

    A couple of vendors (Andover and Siemens) have...

    A couple of vendors (Andover and Siemens) have their own wireless BACnet/MSTP devices. Andover works as advertised, have not had any experience with Siemens' offering. Other option is using IP...
  9. Replies
    4
    Views
    614

    The most beneficial manual will be the Microblock...

    The most beneficial manual will be the Microblock Reference Guide and using EquipmentBuilder to generate programs that you can then dissect and learn about. The simulation feature in Eikon is an...
  10. Replies
    10
    Views
    422

    It probably is using a typical program for each...

    It probably is using a typical program for each piece of typical equipment. Each program has an address in the Ivu to CCN router (just a guess that this is where the programs reside), program 1 has...
  11. Replies
    25
    Views
    2,339

    I have had issues with Danfoss and not setting...

    I have had issues with Danfoss and not setting the max master in the highest MAC addressed drive. I would set it to a couple of addresses above it's MAC and see if that helps.

    kontrol out
  12. Replies
    25
    Views
    2,339

    My guess is JCI@38.4Kbs. As the MAC address...

    My guess is JCI@38.4Kbs. As the MAC address starts at 4, I know JCI reserve 0-3 and generally run at 38.4Kbs.
    Just a guess.

    kontrol out
  13. Software can be one of the freewares online such...

    Software can be one of the freewares online such as WACnet or InneaSoft BACnet Explorer ( demo version ) and even some on SourceForge, device is Contemporary Controls portable BACnet/MST router...
  14. This is why I carry a third-party BACnet to MSTP...

    This is why I carry a third-party BACnet to MSTP router and 3 or 4 BACnet applications. If none of them can discover the device I throw it back in the vendors court and/or installers court if it is a...
  15. Neither, superior Betamax technology! ...

    Neither, superior Betamax technology!

    http://ecx.images-amazon.com/images/I/512T3CT82HL._SL500_AA300_.jpg
    http://cdn.doyouremember.com/wp-content/uploads/2013/06/betamax-1.jpg

    kontrol out
  16. To answer the question in the title of the...

    To answer the question in the title of the thread, a stick. Caveman used a stick to move around the embers in his fire to reduce or increase the btu of the heat source. And that my friend is history....
  17. Replies
    7
    Views
    692

    Java Application Control Engine. BTW it's...

    Java Application Control Engine.

    BTW it's BACnet not BacNet.

    kontrol out
  18. Replies
    5
    Views
    479

    One if the systems I work with regularly does...

    One if the systems I work with regularly does this. It does not have a Multi-State network variable so we use Analog network variables to read and write to Multi-State BACnet objects. When we are...
  19. Replies
    13
    Views
    3,457

    Wow, blast form the past. Lets do the time...

    Wow, blast form the past.

    Lets do the time warp again!

    Those are some of my first post on this forum.

    kontrol out
  20. Just use pitot tubes with 90 degree bends in them...

    Just use pitot tubes with 90 degree bends in them so that the airflow impacts against the baffle/diaphragm.

    21122 Series

    See example 5

    kontrol out
  21. If you decide to use a pressure switch I would...

    If you decide to use a pressure switch I would use impact pressure not static.

    kontrol out
  22. Replies
    17
    Views
    958

    https://www.youtube.com/watch?v=FONN-0uoTHI ...

    https://www.youtube.com/watch?v=FONN-0uoTHI

    kontrol out
  23. Replies
    8
    Views
    572

    :LOL:::DD::LOL: Trudat kontrol out

    :LOL:::DD::LOL:

    Trudat

    kontrol out
  24. Replies
    8
    Views
    572

    Way cool. I'd be happy with that then or today. ...

    Way cool. I'd be happy with that then or today.

    kontrol out
  25. Replies
    18
    Views
    1,973

    Since the power outage, but before that it worked...

    Since the power outage, but before that it worked fine for 15 years, why pay a company $$$ for updates and features that the client doesn't think they need to run their system? I know ALC clients...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event