    On 115 volt power cord the smooth side is hot,...

    On 115 volt power cord the smooth side is hot, ribbed is neutral.
  2. Replies
    135
    Views
    3,124

    cr14, we all still want to encourage you, but...

    cr14, we all still want to encourage you, but 2sac has some valid points, and what about calling traulsen?
    10 pages of going around in the same circle is not the way to get a service call done. best...
  3. :cheers: I think so, the ones I saw also closed...

    :cheers:
    I think so, the ones I saw also closed the LLSV
  4. I've seen it ...........twice maybe in the...

    I've seen it ...........twice maybe in the hundreds of coolers I've seen, always thought it was pretty cool!
  5. You should have never left.........it was down?

    You should have never left.........it was down?
  6. Replies
    7
    Views
    617

    So united finally got Us the pump yesterday, nice...

    So united finally got Us the pump yesterday, nice install. Started up fine, at this point only an eight of a tank left.
    Tank got filled today and it was cycled off at 300 psi. It is controlled by...
  7. Replies
    7
    Views
    617

    Waiting still, 460 volt will be in tomorrow. it...

    Waiting still, 460 volt will be in tomorrow.
    it does seem to run off tank pressure, 2 cap tubes running to control box from tank. Their hooked up to a stat that de-energizes the LLSV. Will let You...
  8. Replies
    7
    Views
    617

    Thanks, right now that tank is sitting in the...

    Thanks, right now that tank is sitting in the florida sun just oozing co2 thru the pressure relieves. So they need to be <50F to stop dumping.........good to know!
  9. Replies
    7
    Views
    617

    CO2 storage tank refrigeration

    I have never worked on one and got a call only to find the compressor has open windings.
    Tommorrow the new one goes in and I'd like
    to know what I'm not seeing inside the 6 ton tank.ie the eval...
  10. Thread: traulsen

    by jappell
    Replies
    4
    Views
    437

    Low charge, find and fix the leak, replace drier...

    Low charge, find and fix the leak, replace drier and evacuate, charge to name plate and Your done.
  11. Replies
    40
    Views
    3,054

    Yeah, for a -10 freezer, different story.

    Yeah, for a -10 freezer, different story.
  12. Replies
    40
    Views
    3,054

    They ARE different.........

    They ARE different.........
  13. Replies
    40
    Views
    3,054

    Jon Baily has an accent! Good stuff!

    Jon Baily has an accent!
    Good stuff!
  14. Replies
    21
    Views
    1,133

    :grin2:

    :grin2:
  15. Replies
    5
    Views
    499

    our gov at work

    http://www.bloomberg.com/news/2013-09-04/safeway-agrees-to-stop-leaks-of-refrigerant-chemical.html?cmpid=yhoo

    good or bad?
  16. any new install or un opened system i always use...

    any new install or un opened system i always use a n2 purge, on old junk sometimes not. Always a micron gauge, it's the only way to tell if it holds, a side note, why do my microns lower after...
  17. Replies
    10
    Views
    989

    if your low on charge the head master will be...

    if your low on charge the head master will be dumping hot gas into the liquid line.......is it real hot to the touch? add a bit of refrigerant and see if it cools down. If so, as previously...
  18. Replies
    21
    Views
    3,127

    Thanks for resrurrecting, '05 was a good year,...

    Thanks for resrurrecting, '05 was a good year, learned alot after we installed a used 5 door freezer with a new copeland sled. 3 days later customer calls about frost on product boxes.........3 to...
  19. Our shop just changes the cap tube, too many...

    Our shop just changes the cap tube, too many heart breaks of starting a new pump just to find it plugged, when We replace a failed compressor. Happy Mothers day!
  20. Replies
    11
    Views
    927

    Experience, and this site really helps guide You...

    Experience, and this site really helps guide You in the right direction, keep up the learning!



    sent from my dumb ass verizon upgrade.
  21. Replies
    32
    Views
    2,207

    Hoshi seems to have proved itself Why mess with...

    Hoshi seems to have proved itself
    Why mess with success
  22. Replies
    14
    Views
    1,410

    Two last week alone. ........ Manitowack!

    Two last week alone. ........ Manitowack!
  23. Replies
    20
    Views
    1,994

    Hey jpena, lighten up and laugh, the smell is no...

    Hey jpena, lighten up and laugh, the smell is no big deal.I'm with ice miester, them old days of one oil is one sweet memory.
  24. Replies
    6
    Views
    1,219

    Ditto on bad valves in comp.

    Ditto on bad valves in comp.
  25. Replies
    14
    Views
    1,481

    icemeister.....

    I'm gonna stop by and buy You lunch someday................You are awesome!
    Arcadia is about as far east as I work but a day trip is overdue, I'm buying!