    Yeah if it had the little sensor with two black...

    Yeah if it had the little sensor with two black wires out the top, that was first generation, If i remember correctly, It had to do with the scroll gears. If you added liquid into discharge side of...
  2. Dont use water based flux!!!! I use the Johnsons...

    Dont use water based flux!!!! I use the Johnsons flux, it looks like petroleum jelly... Not sure what flux your using but I soldered some inch and a half with the water based and well I thought i...
  3. Replies
    5
    Views
    1,027

    Yes, I have seen it on some of the first gen...

    Yes, I have seen it on some of the first gen scrolls. Early Carlyle Milleniums
  4. Replies
    15
    Views
    2,216

    I agree! We have had no trouble with ours, but...

    I agree! We have had no trouble with ours, but then again I do my commissioning above Liebert recommendations. There are so many hack companies that install these units and when I go to commission...
  5. Replies
    15
    Views
    2,216

    We just installed 2 of the new Lieberts with the...

    We just installed 2 of the new Lieberts with the carlyles running 407c. I will have to check with my rep, I was told only 407c is being used. I put one in in August and another in October, they build...
  6. Replies
    15
    Views
    2,216

    Thanks Valdelocc. Dallas Duster why no semi...

    Thanks Valdelocc.
    Dallas Duster why no semi hermetic?
    Liebert uses both Digital Scrolls and Carlyle Semi's w/unloaders. 2 of my sites are all lieberts, 1 is a mixture of Lieberts and Data Aires....
  7. Replies
    15
    Views
    2,216

    Data Center Critical Cooling

    Happy Thanksgiving Everyone!
    I maintain/service 4 different data centers in Las Vegas. 3 of the sites have Liebert systems or Data Aire systems and the other has (2) 20ton Trane split heat pumps.
    I...
  8. Replies
    12
    Views
    631

    They should be enableing the comfort enhanced on...

    They should be enableing the comfort enhanced on the variable speed furnace, make sure they set tonnage, cfm per ton and the enhanced mode at the dip switches
  9. Don't quote me on this, but I believe the true...

    Don't quote me on this, but I believe the true steam does have a mixing valve built in, so when it drains it mixes fresh water with it to drop temp. I thought I read in the manuel it was ok to use...
  10. I had a problem like this with the same unit, my...

    I had a problem like this with the same unit, my problem was with the throat that was needed per rheem. I added the 18" interior plenum and problem solved. However if you do have that throat, them...
  11. Replies
    19
    Views
    3,944

    Like the other gut said read the specs on the...

    Like the other gut said read the specs on the pump, Liebert systems drain there humidifier into there condensate pumps, becareful of the discharge hose from the pimp, dont use the thin vinyl... Good...
  12. obviously if there is an oder, something is...

    obviously if there is an oder, something is causing it.... we don't use charcoal for the filters that would be activated carbon. after you find what is causing the odor, then have a restoration...
  13. Replies
    5
    Views
    712

    prob is i only have enough wires for a standard...

    prob is i only have enough wires for a standard t-stat. cust wants to regulate humidistat from stat not duct... No prob, will install a digistall stat and have to run x-tra wire for a humidistat........
  14. Replies
    5
    Views
    712

    I was hoping the iaq stat would work in the cool...

    I was hoping the iaq stat would work in the cool mode. Yes it comes with the standard humisistat, i'll just re-wire with relays. Our humidity is less than 10%. If it had a variable speed it would...
  15. Replies
    8
    Views
    1,330

    Go Trane for unit Trane cleaneffects for...

    Go Trane for unit

    Trane cleaneffects for filtration

    Nortec RES-DELUX for Humidification
  16. Replies
    1
    Views
    1,115

    IAQ stat --- Humidify in cooling... help

    I was forced installing the new true steam humidifier by honeywell, (i prefer nortec) however the sales guy told customer the IAQ stat matched with the truesteam would work great.... In vegas we have...
  17. Replies
    5
    Views
    712

    Honeywell Truesteam W/ Iaq Stat Need Help

    Ok, I have installed a new true steam with an IAQ stat. here in Vegas we have very little humidity. In the past I use a Nortec resdelux and relays to allow humidity year round, yes even in cooling...
  18. Replies
    10
    Views
    1,062

    is your unit gas heating? could be the limit is...

    is your unit gas heating? could be the limit is going bad or has lint build up. Falsifying the true temp. alowwing fan to come on and cool, then shutting back off
  19. sounds like cond. fan motor might have bad...

    sounds like cond. fan motor might have bad bearings, have you noticed motor staying off while in heat mode? not while in defrost, running in cool mode
  20. Thread: Accumulators

    by IFRZAIR
    Replies
    32
    Views
    2,177

    The part that stores refrigerant is a reciever,...

    The part that stores refrigerant is a reciever, totally diff from an accumulater.
  21. Replies
    13
    Views
    1,995

    First, your coil if is indeed dirty, have it...

    First, your coil if is indeed dirty, have it cleaned. This puts unneccesarry wear and tare on your system and raises operating cost. Blower wheel, these are balanced at the factory, a little dust no...
  22. Replies
    19
    Views
    2,078

    Yeah, what he says:D

    Yeah, what he says:D
  23. [QUOTE=geodude;1738549]Most mowers have bags, use...

    [QUOTE=geodude;1738549]Most mowers have bags, use them.:rolleyes:
    The trane coils will be more effcient due to the shape, then a flat fin tube coil as is standard on all other heat pumps when coated...
  24. Replies
    20
    Views
    1,825

    Sorry Hrdworkingacguy you had me until the Rheem...

    Sorry Hrdworkingacguy you had me until the Rheem part :D

    Here in Vegas Trane is the only Unit, Hands Down. I'm sure in Phoniex you put alot of packs on the roof both res and com.

    Ditzygirl...
  25. Replies
    18
    Views
    1,282

    As GEODUDE stated Variable Speed will help the...

    As GEODUDE stated Variable Speed will help the best keeping rooms closer in temp, I suggest have your contractor give you a quote.

    As far as the thermostat, Totaline (get from Carrier) has a...
  26. Thread: Need help!

    by IFRZAIR
    Replies
    8
    Views
    713

    Make sure the contractor does a load calculation...

    Make sure the contractor does a load calculation per floor, not sure how easy your ductwork is accessable, but any time you have a 2 story with only one unit, you will always have a temp diff....
  27. Replies
    6
    Views
    595

    I agree, as far as the question on running the...

    I agree, as far as the question on running the fan from on position- If an air switch is used with a relay the humidifier will control the fan also
  28. Replies
    16
    Views
    2,557

    lol:D

    lol:D
  29. Replies
    16
    Views
    2,557

    well go out and kick the condensor, if it gets...

    well go out and kick the condensor, if it gets quite, your in good shape;)
  30. Replies
    7
    Views
    2,458

    Don't deal with Amana, butt I don't see why not....

    Don't deal with Amana, butt I don't see why not. As long as you have all the parts to retrofit.
  31. Replies
    16
    Views
    2,557

    Yeah, I agree, but. It is doing it while comp is...

    Yeah, I agree, but. It is doing it while comp is online, just the thought of a larger cond, with out any changes.::eek:
  32. Replies
    16
    Views
    2,557

    Yes, that is a split system. Now you say he up...

    Yes, that is a split system. Now you say he up sized the out door part? In order to help more you will need to post model #'s.
  33. Replies
    16
    Views
    2,557

    Is this a package unit (self contained) or a...

    Is this a package unit (self contained) or a split system (air handler and condensor). If a split system, was the air handler also changed?
  34. Just a thought. I thought I read that the unit is...

    Just a thought. I thought I read that the unit is not that old. Before asking "c" if you should replace system, ask him once he figures which part is bad, what is causing problem, ie; if its the...
  35. on the info given, not enough info to fault...

    on the info given, not enough info to fault either valve or compressor. get a third opinion. unless more info is given, we all will be useless to you
  36. Replies
    20
    Views
    2,072

    unfortunatly can't see dip switch settings. there...

    unfortunatly can't see dip switch settings. there are 8 dip switches, could you tell me 1-8 if there on or off. also need that model # from cond and from furnace.
  37. Replies
    303
    Views
    27,860

    oops forgot a word. Won't be any charge

    oops forgot a word. Won't be any charge
  38. Replies
    303
    Views
    27,860

    Try to find your local Trane distributor, explain...

    Try to find your local Trane distributor, explain what is happening, tell them to get ahold of tech support, demand tech support come out with original installer or with one they reccomend. This is...
  39. Replies
    20
    Views
    2,072

    model num is in the top portion of furnace on...

    model num is in the top portion of furnace on left hand side. if you attempt taking panels of turn power off. make sure unit is not in a heating cycle before shutting off. try to take a pic. of the...
  40. they do work fine when jumped out. if it 20 deg....

    they do work fine when jumped out. if it 20 deg. out side why wait 10 min until 2nd kicks in. being in arizona jumping is fine, but defeats purpose of second stage. there is a reason trane/american...
  41. on your gas pack, there is a w1 and w2 terminal....

    on your gas pack, there is a w1 and w2 terminal. being you only have a singlestage stat, it should be changed to a 2 stage. here in vegas are winters are like yours. in order to use a 2stage stat you...
  42. Replies
    13
    Views
    1,358

    No they get paid flat rate, the more they sell,...

    No they get paid flat rate, the more they sell, the more theymake. get more $$$ for condeming 5 to 10 yr old units.... Just sad. but the good thing now that 13 seer is the standard, we will soon be...
  43. Replies
    13
    Views
    1,358

    Depends, there are some really good techs, we do...

    Depends, there are some really good techs, we do communicate very well. How ever this has been turning into the cut throat cap of the world. Problem is that we have alot of sales techs (parts...
  44. Replies
    11
    Views
    844

    i'm from vegas. Combustion air is required in all...

    i'm from vegas. Combustion air is required in all furnace applications. Fresh air entering into R/A plenum not req. Only commercial req. fresh air. We are starting to see more erv style systems,...
  45. Replies
    13
    Views
    1,358

    grew up in trade with grandpa. full time after...

    grew up in trade with grandpa. full time after high school grad 88.
  46. Poll: TO ALL GIANT FANS (if there is any) LET'S HOPE...

    TO ALL GIANT FANS (if there is any)
    LET'S HOPE JESSICA SHOWS UP
  47. Thread: Actual Cost?

    by IFRZAIR
    Replies
    29
    Views
    3,141

    Quality Is Not Expensive! It's Priceless!!!

    Quality Is Not Expensive! It's Priceless!!!
  48. Replies
    10
    Views
    582

    My thought exactly, since it is so new, I was...

    My thought exactly, since it is so new, I was asked today why they could'nt have it.Them being the home owner. I explained you must be a licensed contractor.
  49. Replies
    10
    Views
    582

    we did send flyers in the area explaining this...

    we did send flyers in the area explaining this issue. We have ordered mor locking caps. now i wonder about this. If they buy the caps, should i be obligated selling them the tool that unlocks the cap?
  50. Replies
    11
    Views
    844

    find out from builder who installing contractor...

    find out from builder who installing contractor is. as stated by previous member unit is still under 1st year labor, should be no charge. and code is same. fresh air not code reg. on res applications