Search:

Type: Posts; User: stenly

Search: Search took 0.00 seconds.

  1. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    It's not a Heat pump, no strips

    It's not a Heat pump, no strips
  2. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    Thanks

    Thanks
  3. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    I just went to the Homepage and found nothing on...

    I just went to the Homepage and found nothing on applying for Pro Membership, what next
  4. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    OK Thanks I'll do that now

    OK Thanks I'll do that now
  5. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    24 volts to ground

    24 volts to ground
  6. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    Yep it is

    Yep it is
  7. Thread: Goodman RTU

    by stenly
    Replies
    11
    Views
    1,145

    Goodman RTU

    I'm having trouble with a Goodman RTU CPG1202103XXXAAA, for some reason the Blower Contactor won't close, it's getting 24 volts from the board and it's the second contactor I put it with the same...
  8. P-trap or Easy trap, they work the same, I like...

    P-trap or Easy trap, they work the same, I like the easy trap cause you can see if there is an obstruction, the little clean out brush works well to.
  9. The gutter is outside

    The gutter is outside
  10. We pipe the primary in the gutter and the...

    We pipe the primary in the gutter and the secondary over a window or door that's used often, that way if the primary gets plugged it will drain through secondary pan and won't shut the unit off. Just...
  11. Replies
    4
    Views
    4,338

    Do you have a coil on top of the furnace?? If you...

    Do you have a coil on top of the furnace?? If you do then it could be blower speed, using the furnaces blower motor to move air across the coil. Usually I find the charge off a little when there's a...
  12. CFM = BTU divided by delta T times 1.08, a guy I...

    CFM = BTU divided by delta T times 1.08, a guy I used to work with taught me that. Also BTU=CFM x delta T x 1.08
  13. Replies
    12
    Views
    11,921

    The chart that I am talking about is the one that...

    The chart that I am talking about is the one that will tell you how many CFM that a particular pipe size is equal to, thats all. Absolutely Manual D has a load of info that any person that is...
  14. Replies
    12
    Views
    11,921

    I would measure the rooms, windows, doors,. Do...

    I would measure the rooms, windows, doors,. Do your insulation and window type, etc. and do a manual j and get your BTUs. Size your cond, go .5 ton bigger on the evap coil or Air handler. Find your...
  15. Replies
    12
    Views
    11,921

    pstu

    Think of it this way, your blower motor is pushing the supply air and pulling the return air, if you have to little return air on a furnace you will trip the high limit because your not moving enough...
  16. We do supply low, return high, this keeps the air...

    We do supply low, return high, this keeps the air circulating better and keeps any dirt, dust or, animal hair from clogging filters. I know someone is going to say that's what there for but I've seen...
  17. Replies
    11
    Views
    911

    When we install Goodman we take the Piston that...

    When we install Goodman we take the Piston that is supplied (in a plastic bag taped to the Condensor) and replace the one at the Evap with that one, never had a callback yet.
  18. Replies
    12
    Views
    11,921

    Mike71

    You can never have to much Return Air, but you can have to little, adding another Return will hurt nothing
  19. Replies
    21
    Views
    5,243

    Maybe your contactor should be 240v, did you ever...

    Maybe your contactor should be 240v, did you ever check original that you took out
  20. Replies
    70
    Views
    5,731

    ????

    ????
  21. Replies
    7
    Views
    5,417

    I use the G5 twin and have never had a problem,...

    I use the G5 twin and have never had a problem, fast and light, especially if you have to rope up on a rooftop
Results 1 to 21 of 22
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event