  1. The only answer I have is to contact you local...

    The only answer I have is to contact you local JCI branch and have them, via the SIS team, create you a new VCT file. I work for JCI and thats what I would have to do if it was me.
  2. Exactly the way Ive always done it, but Im sure...

    Exactly the way Ive always done it, but Im sure someone can edit it IF they had the proper software, Ive just never found it.
  3. Simux, was there actually anything there that...

    Simux, was there actually anything there that told how to edit a .VCT? I have been with JCI almost 10 years and havent ever done it, I have always been told I have to have a table created for me, but...
  4. Replies
    9
    Views
    459

    Also, what kind of controller is this setpoint...

    Also, what kind of controller is this setpoint for? Bacnet or N2? Is it a calculated point under local control? (Some DAT-SP are calculated in many UNT configurations so it has to be asked) Is it an...
  5. Replies
    16
    Views
    1,973

    But if you have no other version of SCT, it will...

    But if you have no other version of SCT, it will at least give you a backup in case you have to replace the NAE. I am assuming that the NAE may be a -0, if so, then you cannot nut it to anything...
  6. Replies
    16
    Views
    1,973

    You can, but you cannot download it back to that...

    You can, but you cannot download it back to that NAE without nutting it to the upgraded version
  7. Replies
    12
    Views
    607

    If you have a NAE55xx-1, or a NAE45 or 35, you...

    If you have a NAE55xx-1, or a NAE45 or 35, you can upgrade to 4.1 without having to purchase the software, if your capable of performing the upgrade yourself, but you will have to be able to back up...
  8. Replies
    12
    Views
    607

    Well, like I said, between 4.0 and 4.1 there was...

    Well, like I said, between 4.0 and 4.1 there was a big difference, which is actually out of the ordinary, usually the big differences occur at the major revisions, but not this time. they actually...
  9. Replies
    12
    Views
    607

    Hey Berg, I don't think that was his issue, he...

    Hey Berg, I don't think that was his issue, he couldn't send commands to multiple points. Igotworms, I noticed something today, although you probably already went and did all the points individually,...
  10. Replies
    16
    Views
    1,973

    The site name and NAE name has to be IDENTICAL,...

    The site name and NAE name has to be IDENTICAL, also, when you get the error, if you highlight the entry, then I believe the details at the bottom becomes available, you can see more info on the...
  11. Replies
    15
    Views
    1,450

    First Osiyo, sorry for your lose, hang in there,...

    First Osiyo, sorry for your lose, hang in there, sounds like you still have people that love you, so you will be alright. Second, your advice is perfect, both for controls or AC work, or car...
  12. Replies
    12
    Views
    607

    I had no problem with the "highlight, right...

    I had no problem with the "highlight, right click" method on a 5.2 site, but the issue may be the version. Try Phantoms idea, I will try to access an older site tomorrow to see if I have any...
  13. Replies
    12
    Views
    607

    Hmm actually the units don't even need to match,...

    Hmm actually the units don't even need to match, I was wrong, so maybe you have an old version?
  14. Replies
    12
    Views
    607

    You have to make sure all the setpoint types are...

    You have to make sure all the setpoint types are the same (deg vs inches etc) Also what version MEA do you have? I have to double check, but I believe some of the older versions might have had an...
  15. Replies
    10
    Views
    1,030

    Set up as "AN" OWS not "THE" OWS though. The NIE...

    Set up as "AN" OWS not "THE" OWS though. The NIE cant be the archive. Use WNCsetup or NCsetup to go into the NCMs and see where the archive is set for, usually the port or IP of the computer with the...
  16. Replies
    10
    Views
    1,030

    Not quite, the NIE cannot be the archive, you...

    Not quite, the NIE cannot be the archive, you need to have an OWS for that because you have to compile the DDL and translate the GPL, then point the NCMs to the OWS with NCSETUP or WNCSETUP so they...
  17. Replies
    10
    Views
    1,030

    If you have an NIE with NCMs you should still...

    If you have an NIE with NCMs you should still have an active PMI workstation on site. Otherwise you would have database maintanance issues since the NIE cant download an NCM. And some of the NCM/IP...
  18. Replies
    26
    Views
    3,413

    And of course we all know FUBAR....

    And of course we all know FUBAR....
  19. Replies
    17
    Views
    2,253

    Hi all, I want to revisit this subject for some...

    Hi all, I want to revisit this subject for some clarity and maybe an update. While looking for an N2/ethernet solution, I have seen whereeveryone says it is viable for NAEs, and I was wondering if...
  20. Replies
    3
    Views
    4,127

    Thanks, that is def a way to go. I had read that...

    Thanks, that is def a way to go. I had read that same thing, but the thing that threw me on the "address" is that one of the boards on one of the existing units (that seems to have a custom cfg) has...
  21. Replies
    15
    Views
    4,224

    and check to be sure there arent any LCT or...

    and check to be sure there arent any LCT or interlock processes controlling the heat, cuz then the vma prog is useless
  22. Replies
    15
    Views
    4,224

    Are you able to upload the vma and provide the...

    Are you able to upload the vma and provide the files? Also, the heating min cfm has to be met for box heat to work, not sure if that would effect the baseboard heat tho, the files would be the most...
  23. Replies
    3
    Views
    4,127

    Carrier Premier Link downloadeer

    Good day,
    I have a site that I am replacing a Premier link board. I have "inherited" a "service tool V" interface and CD. I was able to find how to connect, upload, and re-address via software. I...
  24. Replies
    14
    Views
    3,756

    The Trane site downloads are service pack...

    The Trane site downloads are service pack upgrades, like, you cant get xp for free, but you can get sp3 free. These are not full software packages
  25. Replies
    9
    Views
    1,589

    Your over on your object count, if you do have...

    Your over on your object count, if you do have low COVs between the 2 it could be a factor. I agree also to check for unbound refs as well
  26. Replies
    10
    Views
    850

    And knowing is half the battle!

    And knowing is half the battle!
  27. Replies
    10
    Views
    850

    Im guessing you have no other MS/TP device to...

    Im guessing you have no other MS/TP device to test the NCE trunk, and no other supervisory device to test the FEC. Did you check the voltage on the bus? Since its peer to peer, both should put out...
  28. Replies
    35
    Views
    4,497

    Noskill, you relly think that was in any way...

    Noskill, you relly think that was in any way constructive? Or professional on your part? I feel embarrassed for YOU
  29. Replies
    10
    Views
    1,797

    the saturation timer is used to keep the box from...

    the saturation timer is used to keep the box from switching into heat mode too quickly based on temp, giving time for the process variable to return to a satified value by simply reducing air flow...
  30. Replies
    35
    Views
    4,497

    My experiance is that many companys use plenum...

    My experiance is that many companys use plenum cable, which is fine, but they run it right over flourecent light fixtures, which create interferance, even on a shielded cable in some cases. If you...
  31. Replies
    0
    Views
    395

    extra MP581 and old BMTW

    I have been forced to clean out my shed and have found an unused MP581 w/display and a BCU (BMTW) board on the backplate with 2 standard cap memory cards and the ethernet card. Also 5 VAV boards and...
  32. Replies
    10
    Views
    1,797

    Overide the box mode to satisfied with zn-t less...

    Overide the box mode to satisfied with zn-t less than actual heating setpt, this will bypass the saturation timer. As long as this is a recent hvacpro ver config (7.01^), this will work.
  33. Replies
    35
    Views
    4,497

    Even JCI is now using 22/3 for BacNet, and...

    Even JCI is now using 22/3 for BacNet, and unshielded is even acceptable (I still wouldnt recommend it) for some installs, but only low noise, or in conduit, not near lighting ballasts or around VFDs
  34. Replies
    6
    Views
    799

    I can speak for NAE based JCI, there are a few...

    I can speak for NAE based JCI, there are a few ways to do this. You can make the point so it is not local control, then you can schedule. IF that doesnt work you can make an AV and schedule that, and...
  35. Replies
    12
    Views
    1,457

    Well, it definitaly converted a test DB from 5 to...

    Well, it definitaly converted a test DB from 5 to 4.1, not sure how it will work on a full blown site with programming etc but hey, back it up first and give it a whirl, as metasystech says, you have...
  36. Replies
    12
    Views
    1,457

    Dont know if this is what you meant, sry if Im...

    Dont know if this is what you meant, sry if Im repeating your idea, when you say import export are you speaking point scheduler? Cuz that just might work, altho I havent tryed it. There are def some...
  37. Hmm doesnt do zonebus tho, so you have to get to...

    Hmm doesnt do zonebus tho, so you have to get to the actual n2 bus, no plugging in to the stats or UNT ports, but has diagnostics and no power supply, oh well...tradeoffs...
  38. hmm well actually, we use an edgeport adapter and...

    hmm well actually, we use an edgeport adapter and CVTPRO-300 as recommended by our tech support and supplied by our company, not to say that wont work, but it does say "replaces CVTPRO-101" which is...
  39. Replies
    13
    Views
    1,333

    BTW for what its worth, JCI Guy and Kelly is...

    BTW for what its worth, JCI Guy and Kelly is right, you cannot scan the bus w the NCM on it, you will always get wierd readings on the ncm side of the bus if you split it. (FYI, it will be the side...
  40. Replies
    6
    Views
    1,047

    There was, back about summit ver 11, a cd the...

    There was, back about summit ver 11, a cd the emulated a summit site. I used to have some copies, have not been able to find them as of yet, maybe some else has one they can find a way to get to you....
  41. Replies
    27
    Views
    4,528

    Marc, The few things I have found dont seem to...

    Marc,
    The few things I have found dont seem to apply, but do make sure that IIS is enabled on the PC. Here is some more info, see if it helps.
    The first thing to do is understand what the error...
  42. Replies
    27
    Views
    4,528

    Damn blackbelt beat me to it! ;) Got me while I...

    Damn blackbelt beat me to it! ;) Got me while I was still typing! But not the NUT tool, everything else was correct.
  43. Replies
    27
    Views
    4,528

    Well, actually Marc, you never said you pinged...

    Well, actually Marc, you never said you pinged it, you said you used IP tracker, which will resolve the ip, but isnt the same as a ping command, a ping command will let you know if you comp and the...
  44. Replies
    12
    Views
    1,457

    I'm with jci guy, I dont think you can convert an...

    I'm with jci guy, I dont think you can convert an archive back, but did you restore the backup, convert it, then re-back it up? If not, and you still have 4.1 sct somewhere, you can restore the...
  45. You can always take your own picture, or lift it...

    You can always take your own picture, or lift it from a pdf, but I guess you already knew that....I have a very old trane grapgic library and see no graphic of that chiller, sorry
  46. Replies
    24
    Views
    6,557

    Usually (not always sorry) if you delete all java...

    Usually (not always sorry) if you delete all java versions and connect directly to the NAE via switch and no network (set static IP and subnet to NAE range), it will at least TRY to load the correct...
  47. Replies
    10
    Views
    4,167

    MIGs cant be "uploaded" in the sense that you get...

    MIGs cant be "uploaded" in the sense that you get the VTC file. You can view the point info and capture it, but you cannot upload and save the vtc file, which is vendor specific. Otherwise you are...
  48. Replies
    27
    Views
    4,528

    Try a ping command, ping the NCE IP, then try the...

    Try a ping command, ping the NCE IP, then try the computer name of the NCE (this may or may not be the MAC address with the NAE prefix IE "NAE00108D227B94" depending on if you renamed the unique...
  49. Replies
    26
    Views
    2,939

    Unfortunately most status points default way too...

    Unfortunately most status points default way too low. You dont need to know of a .1 change in temp usually, and you sure dont need a .1 change on a 1-100% damper, but this is the reality, most techs...
  50. Replies
    4
    Views
    920

    Im going to ask questions that you prob already...

    Im going to ask questions that you prob already did or checked, but lets ask anyway to be sure. You can see the controllers from the WS. PMI? Did you try pass through? What ver softwares in AHU?...