Search:

Type: Posts; User: NWMech

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. http://trane.com/Commercial/LiteratureSearchList.a...

    http://trane.com/Commercial/LiteratureSearchList.aspx

    Type in SAHF and you'll find the IOM if you need it.

    This could cause some serious damage to the ductwork if you left it that way. Check...
  2. http://trane.com/Commercial/LiteratureSearchList.a...

    http://trane.com/Commercial/LiteratureSearchList.aspx
  3. Replies
    12
    Views
    1,298

    What is a Intelpac? Trane has these units out...

    What is a Intelpac? Trane has these units out called Intellipaks. That was an amazing rant.
  4. Thread: Coil Cleaner

    by NWMech
    Replies
    22
    Views
    3,309

    The conclusion is use discretion and watch over...

    The conclusion is use discretion and watch over your shoulder. "All run-off from cleaning air conditioning coils with or without detergents shall be captured before it enters a storm drain and...
  5. Thread: Coil Cleaner

    by NWMech
    Replies
    22
    Views
    3,309

    This looks helpful. I emailed them to find out if...

    This looks helpful. I emailed them to find out if the EPA approves for this product to be rinsed down a storm drain.
  6. Thread: Coil Cleaner

    by NWMech
    Replies
    22
    Views
    3,309

    Coil Cleaner

    One of our customers has recently restricted us from chemical coil cleaning. The EPA threatened them with a big fine if all drainage from coil cleaning is not "captured". Has this happened to anyone...
  7. Replies
    6
    Views
    582

    If you work with many Voyagers it's a must to...

    If you work with many Voyagers it's a must to have. If your email was listed I would have already sent it to you.
  8. Replies
    6
    Views
    582

    Do you have the black book?

    Do you have the black book?
  9. Thread: Intellipack IOM

    by NWMech
    Replies
    0
    Views
    511

    Intellipack IOM

    Does anyone have an IOM for an Intellipack from back around '98? Got an older unit I'm trying to determine some details on and digits have changed. Full M/N is SFHFC604LW56C8.
  10. Replies
    14
    Views
    1,506

    I'd say that's a good question, I'd like to hear...

    I'd say that's a good question, I'd like to hear from others on it. My personal opinion is that the most unions offer a great training program. Merit shops have training too, but not always on the...
  11. Replies
    34
    Views
    3,996

    We like to use powerbands on large cooling tower...

    We like to use powerbands on large cooling tower fans. They hold up a lot better even if they are a little harder to work with.
  12. Replies
    14
    Views
    1,506

    The terms apprentice and journeyman are also used...

    The terms apprentice and journeyman are also used in well structured merit based shops. If anyone is called a journeyman after 6 months in a truck then it's not a union shop or a well structured...
  13. Replies
    8
    Views
    880

    Punch in the first 4 letters of you model number...

    Punch in the first 4 letters of you model number and it will pull up an IOM.

    http://trane.com/Commercial/LiteratureSearchList.aspx
  14. Replies
    8
    Views
    880

    It is correctly oriented in your picture. Check...

    It is correctly oriented in your picture. Check out the IOM, it's always in there. You could be getting snow/ice blocking the pickup or harsh wind can even mess things up.
  15. Replies
    14
    Views
    1,506

    Email me your resume

    Email me your resume
  16. Thread: Carrier

    by NWMech
    Replies
    17
    Views
    1,620

    This is going down in California.... ...

    This is going down in California....

    http://www.corp.carrier.com/www/v/index.jsp?vgnextoid=f33c288857106210VgnVCM100000cb890b80RCRD
  17. Replies
    2
    Views
    644

    Been there for the Centravac and Micro class....

    Been there for the Centravac and Micro class. Best bang for your buck, they're principles of sharing information is what makes it so great. I can't stand factory classes that won't even let you take...
  18. Replies
    2
    Views
    977

    Is heat only for morning warmup?

    Is heat only for morning warmup?
  19. Thread: Aaon coil leaks

    by NWMech
    Replies
    24
    Views
    5,654

    We had 2 this summer. Both were 2 years old and...

    We had 2 this summer. Both were 2 years old and at the sheet.
  20. Replies
    0
    Views
    434

    Service Technician Needed - Seattle Area

    The company I'm with is actively looking for a journeyman level technician for commercial service and possibly a small amount of light commercial. We have plenty of work, 40 hrs not a problem. This...
  21. Replies
    27
    Views
    2,707

    You're going to have to tell your office that...

    You're going to have to tell your office that this is a priority and then tell the customer to call you as soon as they notice it. Tell them you can't come out if they reset it first. You can't...
  22. Thread: smardt chiller

    by NWMech
    Replies
    1
    Views
    663

    Well part of your answer is in your question. The...

    Well part of your answer is in your question. The link to all of your answers; http://smardt.com/
  23. Thread: aaon training

    by NWMech
    Replies
    11
    Views
    2,670

    I think the older Mammoth's deserve credit for...

    I think the older Mammoth's deserve credit for their abundant use of relays!
  24. Replies
    13
    Views
    1,132

    I am fairly new to this site and my only 8 years...

    I am fairly new to this site and my only 8 years experience makes mew fairly new to the industry compared to many of you. I will say that I've found so many answers just searching this site. Whenever...
  25. Replies
    2
    Views
    548

    Danfoss makes a great drive that is very easy to...

    Danfoss makes a great drive that is very easy to use. You don't have to order it through Trane though. Check your local danfoss rep, they may be cheaper. I've done quite a few and usually give myself...
  26. Thread: KW Meter

    by NWMech
    Replies
    3
    Views
    578

    Mostly it will be for taking power readings on 3...

    Mostly it will be for taking power readings on 3 phase motors with the possibility of a small amount of data logging. No analyzing really.
  27. Thread: KW Meter

    by NWMech
    Replies
    3
    Views
    578

    KW Meter

    I'm looking for any feedback on a decent quality power meter. Right now I'm looking at the Fluke-345. Anyone?
  28. Replies
    3
    Views
    679

    As far as entry level and just breaking into it...

    As far as entry level and just breaking into it goes there's a lot that can be learned just from reading IOM's and other literature. McQuay has some good principles of centrifugal chiller literature...
  29. Replies
    19
    Views
    2,541

    I know of a large RTAA (really don't want to be...

    I know of a large RTAA (really don't want to be too specific) that was done. It has worked fine, up until 70 degree ambient that is. Turbocor can supposedly provide compressors designed for DX...
  30. Send me your resume if you're still looking.

    Send me your resume if you're still looking.
  31. Replies
    7
    Views
    2,000

    I had one these machines the exact same size that...

    I had one these machines the exact same size that had similar nuisance issues. It already had the low ambient damper kit and eeprom chip swapped out for one with longer low suction trip delay. It was...
  32. Thread: Netbooks

    by NWMech
    Replies
    2
    Views
    500

    Netbooks

    My company is issuing netbooks instead of regular laptops. I was wondering if anyone else out there is using them. The size is a little hard to get used to but all in all it's actually kind of...
  33. Replies
    7
    Views
    1,909

    The artwork is priceless it's the only thing that...

    The artwork is priceless it's the only thing that really got me to post this.
  34. Replies
    7
    Views
    1,909

    I'd say that's a safe assumption...

    I'd say that's a safe assumption...
  35. Replies
    7
    Views
    1,909

    Carrier Evaporative Condenser

    Pictures speak a thousand words. Luckily I was there to scope out replacement. Say is that a factory evaporative condenser retrofit?
  36. Replies
    25
    Views
    1,806

    It's too bad that some don't understand that the...

    It's too bad that some don't understand that the compressor breaker aux switches are there for a reason. I looked at a second opinion job not too long ago on a large 4 compressor circuit. The first...
  37. Replies
    11
    Views
    800

    I was really trying to look into this myself not...

    I was really trying to look into this myself not too long ago. I did one retrofit with NU-22B as a test, but left the company I was with at the time shortly after. The initial retrofit was fine...
  38. Thread: Hudson Tech

    by NWMech
    Replies
    7
    Views
    519

    Thanks klove. I've only used Trane for analysis...

    Thanks klove. I've only used Trane for analysis in the past and am looking for an alternative and it'd be nice to use Hudson since they have an office close to our shop.
  39. Thread: Hudson Tech

    by NWMech
    Replies
    7
    Views
    519

    Hudson Tech

    Does anybody ever use Hudson Technologies for refrigerant and/or oil analysis? I've used their decontamination service before and was pretty happy with them.

    PS-new to the forum, looks like...
  40. Replies
    16
    Views
    3,298

    Those Trane Duplex machines are incredible. I was...

    Those Trane Duplex machines are incredible. I was in LaCrosse for a class last fall and they were building 50 of them for an indoor fully air conditioned golf course in Dubai.
Results 1 to 40 of 58
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event