  1. Replies
    4
    Views
    257

    That is some NASA level programming just to...

    That is some NASA level programming just to determine how many stages of cooling to run! Any idea what spCCPH is used for? I'm guessing cooling cycles per hour? It's set to 0.0011.
  2. Replies
    4
    Views
    257

    You guys rock! That worked. The first time I must...

    You guys rock! That worked. The first time I must have done something wrong because it told me I was missing a .hdr file.

    So the input to the cooling stages control loop is a math function, which...
  3. Replies
    4
    Views
    257

    Honeywell RapidZone Issue

    I've never really had to mess with a RapidZone system before. They usually just work. This one does some things I'm not liking, and I think it's primarily because the RTU is oversized.

    It's about...
  4. Replies
    48
    Views
    2,903

    One problem with replacing the furnace is that...

    One problem with replacing the furnace is that it's a C width. The right furnace (60K btu or so) would be a B width. I don't want to change the evap coil but a C cased coil would look stupid sitting...
  5. Replies
    48
    Views
    2,903

    Wow. What a nightmare that would be. The bathroom...

    Wow. What a nightmare that would be. The bathroom wall, bathroom ceiling, and entire great room ceiling would have to go. After all that I'd still have an oversized system. It would be so much easier...
  6. Replies
    48
    Views
    2,903

    What do you think of the Rawal APR Valve?...

    What do you think of the Rawal APR Valve? Fascinating device. Just learned about it today.
  7. Replies
    48
    Views
    2,903

    You think maybe an ECM would wind up and over-amp...

    You think maybe an ECM would wind up and over-amp itself? I've seen them scream pretty good when a filter is clogged.
  8. Replies
    48
    Views
    2,903

    0.31" at the limit. So -0.49 and +0.31" is 0.8...

    0.31" at the limit. So -0.49 and +0.31" is 0.8 total with the filter. With a dry coil.
  9. Replies
    48
    Views
    2,903

    Am told Lennox has accounted for pressure drop of...

    Am told Lennox has accounted for pressure drop of the coil in their calcs. I can't really get a reading there without drilling a hole in the coil case. What are you getting at? It's probably losing...
  10. Replies
    48
    Views
    2,903

    I think the G41 was built better. Feels like...

    I think the G41 was built better. Feels like heavier metal. The ML193UH feels pretty light. Also mine has a 1/2 HP blower motor which could account for more noise. I think the blower wheel is 10"x10".
  11. Replies
    48
    Views
    2,903

    -0.49" on blower side of filter. +0.24 in supply...

    -0.49" on blower side of filter. +0.24 in supply plenum. As far as ESP, the Lennox Fan Performance Table says "minus filter". If I take readings without the filter I get 0.67 total ESP (-0.32" and...
  12. Replies
    48
    Views
    2,903

    What size? Mine is 110,000 BTUs with a 48C...

    What size? Mine is 110,000 BTUs with a 48C blower. ML193UH
  13. Replies
    48
    Views
    2,903

    I see. Never thought of that. Thanks!

    I see. Never thought of that. Thanks!
  14. Replies
    48
    Views
    2,903

    ESP is about 0.65" without the filter. Not good....

    ESP is about 0.65" without the filter. Not good. Lennox wants 0.5" max. With the 16x25 poly filter the return is -0.49" after the filter.
  15. Replies
    48
    Views
    2,903

    Could be, but If I turn it around then I will see...

    Could be, but If I turn it around then I will see down into the wall and that would not look good in the dining room. It's a low return on the wall. I had the contractor add that return because he...
  16. Replies
    48
    Views
    2,903

    That sounds like a great idea... but you haven't...

    That sounds like a great idea... but you haven't seen my house. I'd have to tear out a wall and half of the first floor ceiling to enlarge the 2nd floor ductwork. The 2nd floor ductwork is in the...
  17. Replies
    48
    Views
    2,903

    There's not much noise from the grills. There was...

    There's not much noise from the grills. There was a return grill that would hum so I took it off and installed strips of tape behind each louvre. It's quiet now. The thing thats undersized are the...
  18. Replies
    48
    Views
    2,903

    I'm not positive, but it could have something to...

    I'm not positive, but it could have something to do with the fact that the installing contractor put a 110,000 BTU furnace and 4 ton A/C in with enough ductwork for about 1,200 CFM all running...
  19. Replies
    48
    Views
    2,903

    Rescue EcoTech looks like exactly what I was...

    Rescue EcoTech looks like exactly what I was looking for. Awesome! Thanks for the info!
  20. Replies
    48
    Views
    2,903

    Convert PSC Blower Motor to ECM?

    I'm tired of my noisy PSC blower motor. It's 1.5 years old, nothing wrong with it, Lennox Merit furnaces are just noisy by nature. This is my second Merit system in a new home. The first one was even...
  21. That's a good idea. I usually work on commercial...

    That's a good idea. I usually work on commercial building systems where the wall is likely to be negative to the room, being connected with the open return plenum above the ceiling. In that case it's...
  22. Thanks for the document! That's exactly what I...

    Thanks for the document! That's exactly what I was wondering about and could not find. Fascinating.
  23. Now that my VP8000 is functioning well I decided...

    Now that my VP8000 is functioning well I decided to upgrade to the Honeywell Z-Wave version and give the other stat to a relative. This allows me to interface with the thermostat through my security...
  24. Thanks, BT. Looks like this is happening. The...

    Thanks, BT. Looks like this is happening. The wall is about 0.5 cooler than the air 1/2" away from the wall.

    I can't understand how 83K BTUs output can be so oversized for a 2,500 square foot...
  25. I reset it last night. That should work,...

    I reset it last night. That should work, especially if it logs data. I left out the fact that this was the thermostat used during my first year in the house. Then I took it out and replaced it with...