    you need composite out the BAbsTime into a...

    you need composite out the BAbsTime into a program object.
    This is code I used to get a global TOD for a graphic..

    BAbsTime now = NviwhateverTime();
    // BAbsTime now = Clock.time();

    String...
  2. Replies
    9
    Views
    635

    I had a BASRTP that I use for onsite programming...

    I had a BASRTP that I use for onsite programming that got jacked up for no apparent reason. I downloaded a new firmware package from ccontrols and that fixed it..
    Looks like a comm issue with the...
  3. Sorry just try http://csicubed then open...

    Sorry just try http://csicubed then open products..
  4. TenantEye by Csi3 is popular and easy to set up.....

    TenantEye by Csi3 is popular and easy to set up.. Free 2 hr trial.. http://csicubed.com/portofolios/tenant-eye/
  5. Thread: CCN AX

    by EMPadvocate
    Replies
    17
    Views
    1,934

    Thanks for the response. The serial device I'm...

    Thanks for the response. The serial device I'm looking at also does TCP/IP (B&B-elec VESR901) also so I'm going to have to play with it.
    Evidently the CCN workstation has to be setup for a...
  6. Thread: CCN AX

    by EMPadvocate
    Replies
    17
    Views
    1,934

    I have a customer with CCN and multiple bldgs...

    I have a customer with CCN and multiple bldgs connected to the 0 network. They have issues with the underground between buildings and my thought was using serial RS485/ethernet converters with the...
  7. Replies
    9
    Views
    1,882

    Maxline (who picked up Infocon driver line) has...

    Maxline (who picked up Infocon driver line) has an N2 driver for Tridium (ibmsN2.jar) that works very good.. I would add the external RS485 comm port card though to the JACE and add separate networks...
  8. Replies
    24
    Views
    2,994

    Current US IRS defines mileage expense as...

    Current US IRS defines mileage expense as .55/mile; sorry for you guys getting paid .50/mile; your company is making .05/mile on you and maybe the IRS needs to know about that.. I always thought...
  9. Replies
    11
    Views
    1,933

    If you're using Tridium you can change the out of...

    If you're using Tridium you can change the out of service attribute using the virtual gateway; this will stay in the BCI config unless its blown out back to default..
  10. Replies
    5
    Views
    604

    Thanks, I dont have a variable SCHEDNUM or MODE...

    Thanks, I dont have a variable SCHEDNUM or MODE in the printout.. There are no jumpers on the terminal block.. I am starting to believe RMTOCC is addressed wrong in the printout. I need to look at it...
  11. Replies
    5
    Views
    604

    Thanks, RMTOCC (0x400F) is at 1 and is not...

    Thanks, RMTOCC (0x400F) is at 1 and is not responding to a write command; I have set OCCPC01S (0x9000) to 0 and also cleared all registers to 0x9008 which I believed cleared all three events...
  12. Replies
    5
    Views
    604

    CCN to Modbus

    I have a 33CNTRAN485 in modbus mode on a 50EJ RTU. The printout from the Comfortview SW had "C48/50E Standard Tier Rooftop" in the status display pages and "C48/50E Standard Tier Rooftop -0,2" in...
  13. After integrating a few server farms I feel that...

    After integrating a few server farms I feel that some IT managers pushed into facilities/sustainability aren't qualified or experienced enough to actually make the initial correct decisions as to an...
  14. Replies
    0
    Views
    357

    Reliatel Analog DAT control

    Anyone have experience doing VAV supply air cooling setpoint on the RTRM board using an analog DCV? The literature also says that this can be accomplished on the RTAM board.. What will yield the best...
  15. Replies
    13
    Views
    1,572

    You need the software from Trane to talk to it...

    You need the software from Trane to talk to it with USB cable; SW is actually pretty well done.. The MAC addresses mean nothing to BACnet MS/TP you actually have to enable it to use it (checkbox);...
  16. Thread: PLC

    by EMPadvocate
    Replies
    30
    Views
    4,384

    The base DL06 has 3 slots open for analog I/O...

    The base DL06 has 3 slots open for analog I/O since one is used for the ECOM100 ethernet device. You can add another modbusTCP device in the ECOM100 configuration or another DL06 or a gateway and...
  17. Replies
    9
    Views
    1,488

    You need to license BACnet IP and everything...

    You need to license BACnet IP and everything BACnet is out on eth1 which you designate as part of the configuration. I just did a HW job with the new BACnet spyders using 3 of the Contemporary...
  18. Thread: PLC

    by EMPadvocate
    Replies
    30
    Views
    4,384

    I use the Automation Direct DL06 for central...

    I use the Automation Direct DL06 for central plant work using Turbocors and VSDs. I use the com2 port for direct compressor control and the ECOM100 card for modbusTCP talking to a JACE.. For the VSD...
  19. Replies
    9
    Views
    1,488

    Doing MS-TP using onboard RS-485 on a large...

    Doing MS-TP using onboard RS-485 on a large network distributed over 4 com ports??? Well good luck with that.. Thats something I wouldn't consider with a JACE. JAVA is built on top of IP and is most...
  20. Replies
    14
    Views
    927

    Engenuity.com is also picking up a lot of BACnet...

    Engenuity.com is also picking up a lot of BACnet product.. They had a new display product I wanted to look at
  21. Replies
    9
    Views
    1,649

    Interstate Batteries has these.. Try #NIC0088...

    Interstate Batteries has these.. Try #NIC0088 which I took off the package..
    They were the JCI suppliers;
  22. Replies
    4
    Views
    730

    If you know Spyders you should'nt have much of a...

    If you know Spyders you should'nt have much of a problem.. just blow out all the nvi, nvo, nci lon network points before you pull in a app off the palette and then re-add - for boolean I used...
  23. Replies
    9
    Views
    2,028

    I am thinking the AX/FX JACE product can't tunnel...

    I am thinking the AX/FX JACE product can't tunnel over the serial port. Perhaps you can use a usb to ms/tp (BASRTP-B from ccontrols.com) from the OWS you have. Don' t have a copy of CCT yet so I...
  24. Replies
    58
    Views
    9,198

    OPC, sounds like your machine is upside down with...

    OPC, sounds like your machine is upside down with evap temp higher than cond side; compressor is in demand limit and won't take off. Hot gas bypass (HGB) will help with these situations.. Use the TC...
  25. I might be mistaken but I did'nt see anything in...