Search:

Type: Posts; User: flasweating

Search: Search took 0.00 seconds.

  1. Replies
    22
    Views
    1,332

    Your not wrong when you finish your post with be...

    Your not wrong when you finish your post with be safe
  2. Replies
    22
    Views
    1,332

    Ok now where getting somewhere.I know this is a...

    Ok now where getting somewhere.I know this is a funny and werd question one that we all went **** what a pain why wouldn't they install a core. It has a core now! And no I'm not taking the core out...
  3. Replies
    22
    Views
    1,332

    Thank you r123 thats what I was looking for this...

    Thank you r123 thats what I was looking for this morning! Isolated cond recovered and instaled CORE! And switch. I was just looking for some glimmer of hope like oh yea trane has a manufacturing list...
  4. Replies
    22
    Views
    1,332

    Thank you mccann and jguy for your quick...

    Thank you mccann and jguy for your quick responce. Thats exactly what I do but hate when you find the core damage or bad threads.
  5. Replies
    22
    Views
    1,332

    schrader cores in equipment

    long time reader first time poster.working on train 130 CGAM chiller need to replace the high pressure switch how can you tell if it has a shrader core I allready backed it out three turns. The...
  6. Replies
    2
    Views
    661

    amps ok. volts running ok. did not have time or...

    amps ok. volts running ok. did not have time or weather today I just came in to last part of this now its mine.thats what i said to service mngr ill look into testing individual components later...
  7. Replies
    2
    Views
    661

    rheem controll board communicating

    have error code 27 and sometimes 28 indicating voltage to high. replaced board per rheem factory tech same problem both stages run 2-4 min and cut out and goes into timeout mode 5 min. com ok. call...
  8. Replies
    152
    Views
    27,903

    Well I did not get the job:deadhorse:Turnes out...

    Well I did not get the job:deadhorse:Turnes out they changed job title.They had it listed as mobile enginer but i guess do to the problems since they posted now they want a 100%chiller tech.I only...
  9. Replies
    152
    Views
    27,903

    jll

    I have applied for a job for JLL ATT. The job ran on career hvac for a month. The district manager called me 1-12-11 and the phone interview went well. We even talked general salary, which i was...
Results 1 to 9 of 9