Search:

Type: Posts; User: skpkey9

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    13
    Views
    620

    There are several variables Is the unit...

    There are several variables
    Is the unit residential or commercial
    Also from brand to brand ESP will vary.
    Need more information to be able to help you but I can tell you that the numbers you...
  2. That is the wrong compressor for what he's trying...

    That is the wrong compressor for what he's trying to accomplish...
    Not enough capacity.

    Hope this helps
  3. I suggest you call a new company or ask for a...

    I suggest you call a new company or ask for a senior tech to diagnose and if that was the senior tech , back to call out a new company.

    Sorry
  4. Thread: In need of

    by skpkey9
    Replies
    9
    Views
    365

    First Co. Also makes them. Hope this helps

    First Co. Also makes them.

    Hope this helps
  5. Replies
    33
    Views
    1,096

    JP- I have it someplace , will look for it in a...

    JP- I have it someplace , will look for it in a bit and get it over to you ..
  6. Replies
    21
    Views
    672

    Yes, But with 438 (MO99) there is a huge loss in...

    Yes, But with 438 (MO99) there is a huge loss in capacity... He need to let this one go.:.02:
    No good deed goes unpunished.:pop:

    Hope this helps...
  7. Replies
    21
    Views
    672

    Run Forest Run !!!:grin2:

    Run Forest Run !!!:grin2:
  8. Replies
    9
    Views
    406

    In cooling the evap check valve is closed, and...

    In cooling the evap check valve is closed, and yes there is a screen.
    It's possible ball is not seating properly causing frosting. For temporary repair, crimp check valve body with pinch off tool...
  9. Replies
    12
    Views
    619

    That bleed resistor is the same thing that you...

    That bleed resistor is the same thing that you find or install on a start cap, no difference

    Hope this helps:.02:
  10. Thread: No Superheat

    by skpkey9
    Replies
    57
    Views
    3,713

    You want the right direction. what is your ...

    You want the right direction. what is your subcool ?

    You came here with half the story and expect people guess the ending of the book when you only give them half the story at best..
    Don't mean...
  11. Replies
    9
    Views
    1,611

    It has an oversized bulb :grin2:

    It has an oversized bulb :grin2:
  12. Replies
    10
    Views
    496

    JP. Ya got me by under a minute ...lol

    JP. Ya got me by under a minute ...lol
  13. Replies
    10
    Views
    496

    2 things one is that they should not be concerned...

    2 things one is that they should not be concerned with air temp but rather product temp , and second if you are taking the box down to 34 or 35 degrees then product temp should not make it that...
  14. Replies
    26
    Views
    1,207

    Thank you:cheers:

    Thank you:cheers:
  15. Replies
    24
    Views
    540

    What is the original compressor model number ?...

    What is the original compressor model number ? The R-12 one...
  16. Replies
    26
    Views
    1,207

    X 3

    X 3
  17. Replies
    26
    Views
    1,207

    When using R-22 for low temp applications you...

    When using R-22 for low temp applications you need to have liquid injection to keep from frying the compressor... and that is why I commented on that post, you kept talking about R-22 as if was an...
  18. Replies
    26
    Views
    1,207

    Re- read your last post ...

    Re- read your last post ...
  19. Replies
    26
    Views
    1,207

    If you try to use R-22 In that compressor for a...

    If you try to use R-22 In that compressor for a low temp application you will destroy it.
  20. Replies
    26
    Views
    1,207

    See what valve is in the unit, possibly stamped...

    See what valve is in the unit, possibly stamped on valve body depending on age and valve. You can alway swap out valve and put 408 in it and be done with it.

    Hope this helps.
  21. Replies
    26
    Views
    1,207

    You are 100% correct MP-66 is the best for low...

    You are 100% correct MP-66 is the best for low temp 12...
  22. Replies
    23
    Views
    1,163

    Instead use a small Phillips screwdriver and go...

    Instead use a small Phillips screwdriver and go up about 9" from the end of the probe and wrap it tightly and make a pig tail. Looks better and works better. Use a larger Phillips to make slot for...
  23. Looking for Service Techs in the Tampa Bay area

    Looking for an experienced service tech with install experience, work duty entails light commercial, restaurant refrigeration, residential and last but not least some hot side work.

    wages based...
  24. Replies
    6
    Views
    420

    [QUOTE=UmmScott;18277841]Ok I wanna get your...

    [QUOTE=UmmScott;18277841]Ok I wanna get your guys' input on this...

    So 1st off I did NOT do the diagnosing on this ice maker. I was just sent to install the parts cuz the other tech was busy. I...
  25. Replies
    29
    Views
    1,471

    Are you sure the arrow is facing the right way......

    Are you sure the arrow is facing the right way...

    Also your differential should not be set for zero...

    Hope this helps...